Second Year IEC Final EXAM Questions
And Answers

Anex _____ in the NEC contains examples of load calculations for
dwellings. - ANSWER>>D

Which of the installations listed below would be a wet location?
-a receptacle installed on the exterior wall of a building
- a run of PVC conduit installed on a fishing pier
-a luminaire installed on a parking lot pole - ANSWER>>all of these

Which of the following is an example of a bare conductor?
- a 12 awg THHN copper wire
- the bare ground wire contained within romex (NM cable) sheathing
-the bare aluminum wire twisted with triplex - ANSWER>>the bare
aluminum wire twisted with triplex

Which of the following statements is TRUE for an individual (or
dedicated) branch circuit that is run in a conduit with other circuits? -
ANSWER>>it can share a neutral with another circuit

Equipment designed to open circuits under ____ shall have an
interrupting rating not less than the nominal circuit voltage and the
current that is available at the line side of the equipment.
- short circuit
-overload
-ground fault - ANSWER>>all of these

, The NEC permits the insulation for an ungrounded conductor to be
_____ in color.
- orange
-black
-brown
-yellow - ANSWER>>any of these

Which of the following locations requires that a three-way switch be
installed at the lower landing and another three-way switch be installed
at the upper landing to control the stair way lighting between the 1st
and 2nd floors? - ANSWER>>a townhome

A 175- amp breaker protects a feeder that originates in a 277/480-volt,
3-ph, 4 wire service panel in an office building. Which of the following
conductors is the smallest size permitted for the feeder ? -
ANSWER>>2/0

A 200-amp breaker protects a feeder that originates in a 120/240 volt,
3 ph, 4 wire service panel in a movie theatre. Which of the following
THHN/THWN conductors is the smallest size permitted for the feeder ?
- ANSWER>>3/0

The maximum number of 3-pole circuit breakers used as service
disconnects permitted in a 3 phase panelboard is ______. - ANSWER>>6

Which of the following are characteristics of THHN/THWN insulation?
- heat-resistant

Document information

Uploaded on
January 22, 2025
Number of pages
14
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
5
Followers
0
Items
1316
Last sold
6 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions