An acceptable reinforcing steel support mechanism for a 24-inch deep footing are? -precast dobie blocks -large,solid pieces of glass -masonry CMU pieces -wooden blocks - correct answer Precast dobie blocks all of the following are true except ? ---Minimum concrete cover for bundled bars of any size need not be greater than 2 inches, unless they are in a member that's permanently cast against earth ---specified concrete cover for headed shear stud reinforcement shall not be less then the cover requirement for the member in which the stud reinforcement is located ---Concrete cover for the flexural members, walls, and compression members with an effective depth of 8-inches can vary -3/8 of an inch ---Concrete cover for members in highly corrosive environments will typically remain the same as cast against earth - correct answer Concrete cover for members in highly corrosive environments will typically remain the same as cast agonist earth As a general rule, Lap splicing bar larger then NO.11 Is? -not permitted -permitted -permitted if bars will be in tension within the structural member -permitted only if bars are within a bundle - correct answer not permitted before new concrete is placed, construction joints must be? -blown free of dirt and debris -wetted ,and standing water removed -sand blasted - treated with a bonding agent - correct answer wetted, and standing water removed grade 60 reinforcing steel has an ultimate strength of? -60,000 -75,000 -90,000 -100,000 - correct answer 90,000 psi The__________may waive requirements for the employment of a special inspection agency if he/she finds that the construction is of minor nature. -building official -engineer or architect of record -owner -all of the above - correct answer building official what is the maximum allowable center to center spacing of spliced bars in a non-contact lap splice for the flexural members? -6 inches -4 inches -8 inches -2 inches - correct answer 6 inches Drilled cast-in place concrete piles that poured with concrete having an f'c of 2500 psi need special inspection? -only when required by the building official -at the engineers discretion -at all times -when poured with concrete having an air entrainment greater then 3% - correct answer at all times The type of portland cement best suited for general use when a moderate heat of hydration is desired is - Type I - Type II - Type III - Type V - correct answer Type II Concrete containing pre-stressed tendons, embedded aluminum, or cast against stay in place galvanized steel forms shall not contain? -lightweight aggregates -pozzolans in excess of 5% -fly ash in excess of 10% -calcium chloride - correct answer calcium chloride billet steel bars are marked by the letter_________on the bars. -S -N -A -W - correct answer S Concrete exposed to water with low permeability requirements shall have a maximum w/c ratio of? -0.4 -0.45 -0.5 -N/A - correct answer 0.5 The following is not allowed in concrete unless it is coated or protected from a reaction with other items in the concrete? -calcium chloride -schedule 20 pipes -galvanized reinforced steel -Aluminum - correct answer Aluminum The last marking on a reinforcing steel bar is - point of origin - size - type of steel - minim

Meer zien Lees minder
Instelling
RCD
Vak
RCD









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
RCD
Vak
RCD

Documentinformatie

Geüpload op
16 januari 2025
Aantal pagina's
14
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

ICC REINFORCED CONCRETE final code
test- 60 questions
An acceptable reinforcing steel support mechanism for a 24-inch deep footing are?

-precast dobie blocks

-large,solid pieces of glass

-masonry CMU pieces

-wooden blocks - correct answer Precast dobie blocks



all of the following are true except ?

---Minimum concrete cover for bundled bars of any size need not be greater than 2 inches, unless they
are in a member that's permanently cast against earth

---specified concrete cover for headed shear stud reinforcement shall not be less then the cover
requirement for the member in which the stud reinforcement is located

---Concrete cover for the flexural members, walls, and compression members with an effective depth of
8-inches can vary -3/8 of an inch

---Concrete cover for members in highly corrosive environments will typically remain the same as cast
against earth - correct answer Concrete cover for members in highly corrosive
environments will typically remain the same as cast agonist earth



As a general rule, Lap splicing bar larger then NO.11 Is?

-not permitted

-permitted

-permitted if bars will be in tension within the structural member

-permitted only if bars are within a bundle - correct answer not permitted



before new concrete is placed, construction joints must be?

-blown free of dirt and debris

-wetted ,and standing water removed

, -sand blasted

- treated with a bonding agent - correct answer wetted, and standing water
removed



grade 60 reinforcing steel has an ultimate strength of?

-60,000

-75,000

-90,000

-100,000 - correct answer 90,000 psi



The__________may waive requirements for the employment of a special inspection agency if he/she
finds that the construction is of minor nature.

-building official

-engineer or architect of record

-owner

-all of the above - correct answer building official



what is the maximum allowable center to center spacing of spliced bars in a non-contact lap splice for
the flexural members?

-6 inches

-4 inches

-8 inches

-2 inches - correct answer 6 inches



Drilled cast-in place concrete piles that poured with concrete having an f'c of 2500 psi need special
inspection?

-only when required by the building official

-at the engineers discretion

-at all times

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
RealGrades Nursing
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
170
Lid sinds
2 jaar
Aantal volgers
52
Documenten
11665
Laatst verkocht
4 weken geleden

4.0

26 beoordelingen

5
12
4
5
3
7
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen