Taken from ICC flashcards and practice book. Studying Chapters 12-24.
The lowest portion of a gas floor furnace shall have not less than a __________ -inch
clearance from grade level.
6 (G2437.4)
Where gas piping is located within a framing member and is less than _________
inches from the framing member face to which wall, ceiling or floor membranes will be
attached, the piping shall be protected by shield plates.
1 1/2 (G2415.7.2)
For gas appliance installations using the two-permanent-openings method for outdoor
combustion air, one opening commencing within _____ inches of teh top and one
commencing within _______ inches of the bottom of the enclosure, shall be provided.
12, 12 (G2407.6.1)
Vent piping on oil tanks shall be not smaller than _______ -inch pipe.
1 1/4 (M2203.4)
Components of a solar thermal energy system that might be subjected to a vacuum
during operation or shutdown shall be designed to withstand such a vacuum or shall be
protected with _____ _____ _____.
vacuum relief valves (M2301.2.4)
BTU is the abbreviation for _____ _____ ____, which is the quantity of heat required to
raise the temperature of 1 pound of water 1 F.
British Thermal Unit (G2403)
The maximum amount of fuel oil stored above ground or inside a building shall be
______ gallons.
660 (M2201.2)
Attics containing appliances shall be provided with an opening and a clear and
unobstructed passageway large enough to allow removal of the largest appliance, but
not less than _____ inches high and _____ inches wide and not more than _______
feet long.
30
22
20
(M1305.1.2)
For mechanical system installations in flood hazard areas, _____ _____ openings shall
be located at or above the required elevation
combustion air
,(M1701.2)
Attics containing mechanical appliances shall be provided with an opening and a clear
and unobstructed passageway large enough to allow removal of the _____ appliance.
largest
(M1305.1.2)
Where a space for a _____________________ _____________________ is provided,
an exhaust duct system shall be installed.
clothes dryer
M1502.4.8
Gas appliance shutoff valves shall be located in the same room as the appliance and
not further than _____________________ feet from the appliance.
6
(G2420.5.1)
Manually operated vent ________ shall not be installed except in connectors or
chimneys serving solid fuel-burning appliances.
dampers
M1802.2.1
Boiler pressure relief valve discharge shall be piped to drains by gravity to within
________ inches of the floor or to an open receptor.
18
M2002.4
Gas vents that are over 12 inches in size or are located less than 8 feet from a vertical
wall or similar obstruction shall terminate not less than _______ feet above the highest
point where they pass through the roof.
2
G2427.6.4, Item 2
Sauna heaters shall be equipped with a thermostat that will limit room temperature to
not greater than ___ degrees F
194
M1902.4
Fuel-gas-fired clothes dryer exhaust duct size shall be _____ inches nominal in
diameter
4
, G2439.7.1
A Type-B-W gas vent shall terminate not less than _______ feet in vertical height above
the bottom of the wall furnace.
12
G2427.6.5
Fuel gas appliance connectors shall have an overall length not to exceed _____ feet.
6
G2422.1.2.1
Transition ducts used to connect the dryer to the exhaust duct system shall be .. not
more than ___________ feet in length
8
G2439.7.3
A 4-inch radius mitered 45-degree elbow dryer exhaust duct fitting shall reduce the
maximum 35-foot length of a dryer duct by ______ feet _____ inches.
2
6
(M1502.4.6.1)
Mechanical appliances having an ignition source shall be elevated such that the source
of ignition is not less than _____ inches above the floor in garages.
18
M1307.3
Fuel gas piping installed across roof surfaces shall be elevated not less than ___ inches
above the roof surface
3 1/2
G2415.9
Shield plates, where required to cover
the area of concealed gas piping, shall
be a minimum No. _________ gage.
16
G2415.7.3
Underground fuel gas piping systems shall be installed a minimum depth of ___ inches
below grade