MA 2ND CLASS FIREMAN'S PRACTICE EXAM/ NEWEST 2025 WITH COMPLETE QUESTIONS AND CORRECT VERIFIED ANSWERS/ WELL GRADED A+//LATEST VERSION After installing a new gauge glass, the proper procedure for returning the glass to service is a) crack open both the top and bottom valves b) open the drain and crack both the bottom and top valves c) open the drain and crack open the top valve d) open the drain and crack open the bottom valve - CORRECT ANSWERS-c) open the drain and crack open the top valve The steam pressure gauge is graduated in a) absolute pressure b) inches of pressure c) pounds per square inch d) pounds per square foot - CORRECT ANSWERS-c) pounds per square inch One of the purposes of the water column is to a) indicate to the operator the level of the water in the boiler b) easily find the pressure in the boiler c) dampen the oscillation of the water in the gauge glass d) prevent the boiler from priming - CORRECT ANSWERS-c) dampen the oscillation of the water in the gauge glass The gauge glass should be blown down a) daily b) weekly c) monthly d) yearly - CORRECT ANSWERS-a) daily The flame failure control is tested by a) blowing down the low-water cutoff b) adjusting the pressuretrol c) calling the inspector d) securing the fuel supply to the burner - CORRECT ANSWERS-d) securing the fuel supply to the burner Which of the following controls operates due to changes in temperature? a) Fire eye b) Vaporstat c) Aquastat

Meer zien Lees minder
Instelling
MA 2ND CLASS FIREMAN\\\'S PRACTICE
Vak
MA 2ND CLASS FIREMAN\\\'S PRACTICE










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
MA 2ND CLASS FIREMAN\\\'S PRACTICE
Vak
MA 2ND CLASS FIREMAN\\\'S PRACTICE

Documentinformatie

Geüpload op
12 januari 2025
Aantal pagina's
16
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

MA 2ND CLASS FIREMAN'S PRACTICE EXAM/
NEWEST 2025 WITH COMPLETE QUESTIONS
AND CORRECT VERIFIED ANSWERS/ WELL
GRADED A+//LATEST VERSION

After installing a new gauge glass, the proper procedure for returning the glass to
service is
a) crack open both the top and bottom valves
b) open the drain and crack both the bottom and top valves
c) open the drain and crack open the top valve
d) open the drain and crack open the bottom valve - CORRECT ANSWERS-c) open the
drain and crack open the top valve

The steam pressure gauge is graduated in
a) absolute pressure
b) inches of pressure
c) pounds per square inch
d) pounds per square foot - CORRECT ANSWERS-c) pounds per square inch

One of the purposes of the water column is to
a) indicate to the operator the level of the water in the boiler
b) easily find the pressure in the boiler
c) dampen the oscillation of the water in the gauge glass
d) prevent the boiler from priming - CORRECT ANSWERS-c) dampen the oscillation of
the water in the gauge glass

The gauge glass should be blown down
a) daily
b) weekly
c) monthly
d) yearly - CORRECT ANSWERS-a) daily

The flame failure control is tested by
a) blowing down the low-water cutoff
b) adjusting the pressuretrol
c) calling the inspector
d) securing the fuel supply to the burner - CORRECT ANSWERS-d) securing the fuel
supply to the burner

Which of the following controls operates due to changes in temperature?
a) Fire eye
b) Vaporstat
c) Aquastat

,d) Pressuretrol - CORRECT ANSWERS-c) Aquastat

The pressure-sensitive device attached to the fan housing of a fully automatic burner
starts operating when there is
a) flame failure
b) too large an increase in primary air
c) fan failure
d) too large an increase in secondary air - CORRECT ANSWERS-c) fan failure

If the pressuretrol starts the burner and ignition failed to take place, the control that
protects the boiler is the
a) low-water cutoff
b) flame failure cutoff
c) vaporstat
d) aquastat - CORRECT ANSWERS-b) flame failure cutoff

The pressure-sensitive device in Question 91 is sometimes called a(n)
a) pressuretrol
b) aquastat
c) thermostat
d) vaporstat - CORRECT ANSWERS-d) vaporstat

Draft is measured in
a) ounces per square inch
b) inches of water
c) inches of mercury
d) pounds per square inch - CORRECT ANSWERS-b) inches of water

Which of the following is used to measure temperature?
a) Fyrite analyzer
b) Vaporstat
c) Orsat analyzer
d) Pyrometer - CORRECT ANSWERS-d) Pyrometer

The main stop valve is located on the
a) oil supply line
b) condensate breaker
c) vacuum breaker
d) steam line - CORRECT ANSWERS-d) steam line

OS&Y stands for
a) overhead steam and yield
b) outside screw and yoke
c) outside stem and yoke
d) overall stainless and yoke - CORRECT ANSWERS-b) outside screw and yoke

, An interlock control is a(n)
a) device that prevents attempts to fire unless safe
b) wrench that secures the burner
c) device that prevents the main stop from opening
d) automatic control lock - CORRECT ANSWERS-a) device that prevents attempts to
fire unless safe

Trial for ignition refers to the
a) burner testing period
b) time the main fuel valve stays open for ignition
c) flame light test
d) the flame scanner detecting the pilot flame - CORRECT ANSWERS-d) the flame
scanner detecting the pilot flame

More than one safety valve is required on boilers that have over
a) 100 ft^2 of heating surface
b) 500 ft^2 of heating surface
c) 100 PSI MAWP
d) 500 PSI MAWP - CORRECT ANSWERS-b) 500 ft^2 of heating surface

Two or more boilers that are equipped with manholes and are connected to a common
header must have
a) two stop valves with a drain coming off between them
b) both a nonreturn and a gate stop valve
c) both a globe and a gate stop valve
d) a stop and a check valve - CORRECT ANSWERS-a) two stop valves with a drain
coming off between them

Before the gas pilot ignites, the
a) low-water cutoff must be checked
b) gas pressure must be at least 10 PSI
c) furnace must be purged
d) oil pressure must be at least 50 PSI - CORRECT ANSWERS-c) furnace must be
purged

If the main fuel valve is closed while the burner is on,
a) there will be high water
b) there will be low water
c) the oil temperature will drop
d) the flame detector will activate - CORRECT ANSWERS-d) the flame detector will
activate

Pyrometers measure
a) temperature
b) draft
c) smoke density
$17.99
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
gideonngari

Maak kennis met de verkoper

Seller avatar
gideonngari Teachme2-tutor
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
6
Lid sinds
1 jaar
Aantal volgers
0
Documenten
794
Laatst verkocht
1 week geleden

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen