100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

API 653 Data Sheets Exam Questions and Answers 100% Pass

Rating
-
Sold
-
Pages
16
Grade
A+
Uploaded on
10-01-2025
Written in
2024/2025

API 653 Data Sheets Exam Questions and Answers 100% Pass Fitness For Service - API 579 Low Pressure Storage Tanks - API 620 Risked Based Inspection - API 580 Cathodic Protection - API 651 Tank Bottom Linings - API 652 Welding on in service equipment containing flammables - API 2201 NDE Procedure Guidlines - ASME Section V Acceptance Standards for RT of welds - ASME Section 8, Div. 1 Alternative evaluation for pits and LTA's - ASME Section 8, Div. 2 Welder Qualification - ASME Section IX Weld Procedure Qualification - ASME Section IX Impact testing method and equipment requirements - ASTM A370 EMILY CHARLENE © 2025, ALL RIGHTS RESERVED 2 Requirement for new welding electrodes - AWS NDE personnel qualification (RT and UT flaw detection) - ASNT SNT-TC-1A API 650 Appendix for frangible roofs - Appendix F API 650 Appendix for hot tanks - Appendix M Maximum allowed vertical length of pits on a tank shell - 2" in 8" Line Max allowed length of pits in the critical zone th

Show more Read less
Institution
Api 653
Course
Api 653










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Api 653
Course
Api 653

Document information

Uploaded on
January 10, 2025
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

API 653 Data Sheets Exam
Questions and Answers 100% Pass

Fitness For Service - ✔✔API 579


Low Pressure Storage Tanks - ✔✔API 620


Risked Based Inspection - ✔✔API 580


Cathodic Protection - ✔✔API 651


Tank Bottom Linings - ✔✔API 652


Welding on in service equipment containing flammables - ✔✔API 2201


NDE Procedure Guidlines - ✔✔ASME Section V


Acceptance Standards for RT of welds - ✔✔ASME Section 8, Div. 1


Alternative evaluation for pits and LTA's - ✔✔ASME Section 8, Div. 2


Welder Qualification - ✔✔ASME Section IX


Weld Procedure Qualification - ✔✔ASME Section IX


Impact testing method and equipment requirements - ✔✔ASTM A370




EMILY CHARLENE © 2025, ALL RIGHTS RESERVED 1

,Requirement for new welding electrodes - ✔✔AWS


NDE personnel qualification (RT and UT flaw detection) - ✔✔ASNT SNT-TC-1A


API 650 Appendix for frangible roofs - ✔✔Appendix F


API 650 Appendix for hot tanks - ✔✔Appendix M


Maximum allowed vertical length of pits on a tank shell - ✔✔2" in 8" Line


Max allowed length of pits in the critical zone that can be repaired by weld build up -

✔✔2" in 8" arc


Radial length of critical zone measured from shell - ✔✔3"


Bottoms- suggested pad thickness - ✔✔3-4"


Minimum distance between clusters of surface porosity - ✔✔4"


Minimum dimension of shell lap-patch - ✔✔4"


Minimum radius of shell flush-patch - ✔✔6"


When calculating tmin for shell LTA, minimum distance away from a rivet where "E" is

always 1.0 - ✔✔6"


Minimum size of a bottom lap-patch that does NOT cross a bottom seam - ✔✔6"


Minimum distance between a bottom lap patch and the shell for patches that do NOT

extend to the shell - ✔✔6"




EMILY CHARLENE © 2025, ALL RIGHTS RESERVED 2

, If reusing shell plates, minimum distance to cut from existing shell welds (if plates are

not deseamed) - ✔✔6"


Minimum diagnostic length of RT for vertical or horizontal welds - ✔✔6"


Minimum length of RT when qualifying a welder with RT using a coupon or 1st

production weld - ✔✔6"


Minimum length of RT when qualifying a weld operator with a test coupon - ✔✔6"


Minimum distance to overlap a shell weld when using a lap patch - ✔✔6"


Area to dig when checking for soil-to-air corrosion - ✔✔6-12"


Typical size of a vacuum box - ✔✔6"X30"


Minimum dimension of a shell flush patch - ✔✔12" or 12 times thickness of replacement

plate, whichever is greater


Bottoms-minimum distance a 3 lap joint can be from: other 3 lap joints, the shell or

annular plate joints - ✔✔12"


Minimum dimension of bottom lap patch that crosses a bottom seam - ✔✔12"


Foundations- suggested height above grade for new tank bottoms - ✔✔12"


When adding a shell flush patch that extends to a horizontal shell weld, minimum

distance to cut the horizontal weld past the new vertical welds - ✔✔12"




EMILY CHARLENE © 2025, ALL RIGHTS RESERVED 3

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EmilyCharlene Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
443
Member since
2 year
Number of followers
138
Documents
21009
Last sold
2 days ago
Charlene\'s Scholastic Emporium.

Your Actual and Virtual Exam Tests Excellent Tutor.

3.6

97 reviews

5
45
4
13
3
15
2
7
1
17

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions