Fire Inspector 2 Questions and Answers 100% Solved Class ____ fires: fire of flammable and combustible liquids and gases such as gasoline, kerosene and propane B Pressure tanks should be filled ______ of water with ____ psi 2/3; 75psi Fire extinguishers >40lbs should be mounted no higher than ______ feet from the floor 3 ½ _______ _______ is an aqueous solution of either potassium carbonate and water or potassium acetate and water Wet chemical _______ _______ extinguishers limitations are the clean-up Dry chemical _____ ______ agents are difficult to clean up due to water repellant Dry chemical When liquid propane gas is stored in the same area as flammable or combustible liquid, the containers must be at least ______ feet apart 20 feet Fire protection engineers have established _____ PSI as a minimum required residual pressure when computing the available water for flow test results. 20psi The most common gallonage rating for horizontal shaft pumps in use today are _____ - _____ GPM. 500 - 1500 gpm A fire pump serving a standpipe system should be tested ______ weekly A fire department pumper can effectively supply around ______ feet in a high rise building depending on hydrant pressure and other factors. 450 feet Class 2 standpipe is for __________ use occupational Standpipe classifications: 1. 2 3. 1. Fire Dept only 2. Occupant use only 3. Both Fire Dept and Occupant use NFPA 13D requires _______ for any sprinkler 18 GPM Minimum water supply for a class 1 or 3 standpipe system is _____ gpm for at least 30mn with 65psi residual pressure at the highest outlet. 500 Stored material should not be stacked closer than ____ inches to a sprinkler head 18 inches _______ system is used when it is especially important that water damage be prevented, even if the sprinkler pipes should break accidentally. Preaction Fire dampers are usually activated by _____ ______ fusible links ________ detectors are - activated by heat (expansion) and are self-resetting (automatic) Bimetallic Freeboard should never be more than ___ inches 6 _________ ________ is wood chips glued together to make flat sheets Particle board The maximum size for an approved safety can is ___ gallons 5 Open burning fire should not be allowed within ______ feet of a structure 50

Meer zien Lees minder
Instelling
Fire Inspector 2
Vak
Fire Inspector 2










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Fire Inspector 2
Vak
Fire Inspector 2

Documentinformatie

Geüpload op
10 januari 2025
Aantal pagina's
19
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

  • fire inspector 2

Voorbeeld van de inhoud

Fire Inspector 2 Questions and Answers
100% Solved
Class ____ fires: fire of flammable and combustible liquids and gases such as gasoline, kerosene and
propane

B




Pressure tanks should be filled ______ of water with ____ psi

2/3; 75psi




Fire extinguishers >40lbs should be mounted no higher than ______ feet from the floor






_______ _______ is an aqueous solution of either potassium carbonate and water or potassium acetate
and water

Wet chemical




_______ _______ extinguishers limitations are the clean-up

Dry chemical




_____ ______ agents are difficult to clean up due to water repellant

Dry chemical

,When liquid propane gas is stored in the same area as flammable or combustible liquid, the containers
must be at least ______ feet apart

20 feet



Fire protection engineers have established _____ PSI as a minimum required residual pressure when
computing the available water for flow test results.

20psi




The most common gallonage rating for horizontal shaft pumps in use today are _____ - _____ GPM.

500 - 1500 gpm




A fire pump serving a standpipe system should be tested ______

weekly




A fire department pumper can effectively supply around ______ feet in a high rise building depending on
hydrant pressure and other factors.

450 feet




Class 2 standpipe is for __________ use

occupational




Standpipe classifications:

1.

2

3.

, 1. Fire Dept only

2. Occupant use only

3. Both Fire Dept and Occupant use




NFPA 13D requires _______ for any sprinkler

18 GPM




Minimum water supply for a class 1 or 3 standpipe system is _____ gpm for at least 30mn with 65psi
residual pressure at the highest outlet.

500




Stored material should not be stacked closer than ____ inches to a sprinkler head

18 inches




_______ system is used when it is especially important that water damage be prevented, even if the
sprinkler pipes should break accidentally.

Preaction




Fire dampers are usually activated by _____ ______

fusible links




________ detectors are - activated by heat (expansion) and are self-resetting (automatic)

Bimetallic

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ApassExams Teachme2-tutor
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
29
Lid sinds
2 jaar
Aantal volgers
10
Documenten
1710
Laatst verkocht
4 maanden geleden
Nursing Perfection Study Station

Just For You...Yes You....EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially; psychology, Nursing, Human resource Management and Mathematics Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that's why I'm one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work

3.0

2 beoordelingen

5
1
4
0
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen