100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NATE Heat Pump Exam Best Answers

Beoordeling
-
Verkocht
-
Pagina's
11
Cijfer
A+
Geüpload op
02-01-2025
Geschreven in
2024/2025

NATE Heat Pump Exam Best Answers NATE Heat Pump Exam Best Answers NATE Heat Pump Exam Best Answers NATE Heat Pump Exam Best Answers NATE Heat Pump Exam Best Answers

Instelling
NATE Heat Pump
Vak
NATE Heat Pump









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
NATE Heat Pump
Vak
NATE Heat Pump

Documentinformatie

Geüpload op
2 januari 2025
Aantal pagina's
11
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

NATE Heat Pump Exam Best Answers 2024-2025
A disc-type, close-on -rise pressure control is being used as a loss-of-charge limit control on the liquid
line of a heat pump. The control must sense a specified pressure within __ _______ of a compressor
start for the compressor to continue operation. If the cut-in setting of the control drifts lower, the
system is less likely to shut down as a result of a small leak - ANSWER-15 seconds



The sensor of an outdoor ambient thermostat for a heat pump system is typically installed in the -
ANSWER-entering airstream to the outdoor coil


A high pressure limit control, used to shut down a compressor if condensing pressure becomes
excessive, is typically installed to sense - ANSWER-compressor discharge line pressure



Low pressure limit controls are often placed in the suction line of a heat pump for two purposes. They
are to - ANSWER-protect the compressor if suction pressure drops too low and to detect a loss of a
charge



The function of a reversing valve is to provide - ANSWER-heating and/or cooling



The relationship between inrush current and holding current of a relay coil is inrush current is -
ANSWER-always greater than holding current


The capability of electronic programmable room thermostat to reset the set point early so that the
space temperature reaches a set temperature at a specific time is called - ANSWER-computed
recovery



When using a double (dual) element time-delay fuse with a 20 amp motor, the maximum fuse size
should be - ANSWER-25 amps



According to fire protection codes, fire dampers should be used in any air duct that - ANSWER-passes
through all walls or partitions of a light commercial installation

, When the capacity of a heat pump in heating, measured in Btu's, is the same as the heat loss of a
structure, the system is said to have reached its - ANSWER-balance point



A suction line accumulator should be used in a residential heat pump only when - ANSWER-
recommended by the manufacturer if long refrigerant lines increase system charge over recommended
maximum charge



The measurement of a heat pumps efficiency is often stated using its "Coefficient of Performance" or
COP. The COP of a heat pump is the heat pumps - ANSWER-heat output in watts divided by its total
electrical input in watts



The purpose of calculating the heat loss at an outside design temperature is to - ANSWER-select the
appropriate equipment based on Btu output



The minimum circuit amp listed on a units' data plate is used to determine the - ANSWER-max fuse or
circuit breaker size.



Heat pumps are particularly sized based on the - ANSWER-cooling load



The effective method of reducing sound when AHU is located in a closet is to use - ANSWER-vibration
isolators



When wiring a 20 amp FLA motor, the minimum amp fuse or circuit breaker should be - ANSWER-25



The typical staging of a two stage HP system uses the deviation of the t-stat setting to determine -
ANSWER-when to engage each stage.


The purpose of a sequencer in a HP with an AUX 20 kW electric heater is to - ANSWER-energize one or
two elements and the blower then energize the other elements in timed intervals.
$20.99
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
ngecijoy9

Maak kennis met de verkoper

Seller avatar
ngecijoy9 Teachme2-tutor
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
0
Lid sinds
1 jaar
Aantal volgers
0
Documenten
11
Laatst verkocht
-

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen