Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

NICET LEVEL 1 FIRE ALARM SYSTEMS EXAM STUDY QUESTIONS WITH REVISED ANSWERS NEW UPDATE GUARANTEED PASS | RATED A+

Rating
-
Sold
-
Pages
11
Grade
A+
Uploaded on
29-12-2024
Written in
2024/2025

NICET LEVEL 1 FIRE ALARM SYSTEMS EXAM STUDY QUESTIONS WITH REVISED ANSWERS NEW UPDATE GUARANTEED PASS | RATED A+ A pathway shall be designated as Class when it does not include a redundant path and operational capability stops at a single open and operational capability is maintained during the application of a single ground fault? - Answer Class B EMT shall be securely fastened in place at least every feet. - Answer 10 feet The minimum clear safe working distance from an energized 240 volt breaker panel that has the cover removed is ft from the wall in front the panel. - Answer 3 feet Wall mounted audible appliances shall have their tops above the finished floors at heights of not less than inches and below the finished ceilings at distances of not less than 6 inches? - Answer 90 inches A minimum db ambient sound level with a 6 hour exposure time requires hearing protection? - Answer 92 db Ground fault circuit interrupters are required for all 120 volts power tools on a construction site unless . - Answer The work area is dry Consider the use of a multimeter in troubleshooting a fire alarm circuit. The circuit has an end of the line resistor with a value of 4.7ohms. With the circuit disconnected from power, the positive leg of a fire alarm circuit is metered to a known ground with the meter set to the 10kohm setting. Consider that the circuit is properly functioning. The expected reading on the multimeter is ohms? - Answer Infinity Including new systems and addition or alterations to existing systems, which of the following is not required to be delivered to the owner upon final acceptance of the system? - Answer Inspection & Testing records, Central station history log According to NFPA 72, section of the record of completion is used to note the input voltage? - Answer Section 5.1.11 Which of the following is not one of the criteria to be a designated a confined space? - Answer A room that locks when the door is closed. According to NFPA 72 the onsite location of the required record documents and specific software is notes in section of the Record of Completion? - Answer Section 3 According to NFPA 72 the Record of Completion section 12.1 is required to be signed by ? - Answer System Installation Contractor

Show more Read less
Institution
NICET LEVEL 1 FIRE ALARM SYSTEMS
Course
NICET LEVEL 1 FIRE ALARM SYSTEMS

Content preview

NICET LEVEL 1 FIRE ALARM SYSTEMS EXAM STUDY
QUESTIONS WITH REVISED ANSWERS NEW UPDATE
GUARANTEED PASS | RATED A+

A pathway shall be designated as Class when it does not include a redundant path and
operational capability stops at a single open and operational capability is maintained during the
application of a single ground fault? - Answer>>> Class B

EMT shall be securely fastened in place at least every feet. - Answer>>> 10 feet
The minimum clear safe working distance from an energized 240 volt breaker panel that has
the cover removed is ft from the wall in front the panel. - Answer>>> 3 feet
Wall mounted audible appliances shall have their tops above the finished floors at heights of
not less than inches and below the finished ceilings at distances of not less than 6 inches?
- Answer>>> 90 inches

A minimum db ambient sound level with a 6 hour exposure time requires hearing
protection? - Answer>>> 92 db

Ground fault circuit interrupters are required for all 120 volts power tools on a construction site
unless . - Answer>>> The work area is dry

Consider the use of a multimeter in troubleshooting a fire alarm circuit. The circuit has an end
of the line resistor with a value of 4.7ohms. With the circuit disconnected from power, the
positive leg of a fire alarm circuit is metered to a known ground with the meter set to the
10kohm setting. Consider that the circuit is properly functioning. The expected reading on the
multimeter is ohms? - Answer>>> Infinity

Including new systems and addition or alterations to existing systems, which of the following is
not required to be delivered to the owner upon final acceptance of the system? - Answer>>>
Inspection & Testing records, Central station history log

According to NFPA 72, section of the record of completion is used to note the input voltage? -
Answer>>> Section 5.1.11

Which of the following is not one of the criteria to be a designated a confined space? -
Answer>>> A room that locks when the door is closed.

, According to NFPA 72 the onsite location of the required record documents and specific
software is notes in section of the Record of Completion? - Answer>>> Section 3

According to NFPA 72 the Record of Completion section 12.1 is required to be signed
by ? - Answer>>> System Installation Contractor

What is the minimum size grounding conductor that cab be used when wiring a fire alarm
control panel to a 20 amp. Breaker? - Answer>>> #12

The location of the branch circuit overcurrent protective device shall be permanently identified
at the fire alarm control unit . Which of the following is a requirement of the circuit
disconnecting means? Select Three - Answer>>> 1.Red identification 2.Accessible only to
qualified personnel 3.Identified as FIRE ALARM CIRCUIT

The secondary power supply should automatically provide power to protect premises system
within seconds Whenever the primary power supply voltage is insufficient for required
systems operation. - Answer>>> 10 seconds

Consider a fire alarm system which does not use an uninterruptible power supply for primary
power. Independent and reliable power supply shall be provided? - Answer>>> 2
independent

You are using a power tool that has a 3 prong (grounded) plug. The only outlets available are 2
prong (non grounded). What can be done? - Answer>>> Locate a 3 prong plug or used a tool
with a 2 prong plug.

The power source for a power limited fire alarm circuit shall be a listed PLFA or Class
transformer? - Answer>>> Class 3 transformer

Which of the following is a symptom of heat stroke? - Answer>>> Red skin, Elevated Body
Temperature, Rapid, Weak pulse

The maximum number of 14 AWG, RHH conductors permitted in 1/2 inch EMT is ?-
Answer>>> 4

The distance between smoke detectors shall not exceed a nominal spacing of feet? -
Answer>>> 30 feet

A portable ladder shall support at least times the maximum intended load. - Answer>>>

Written for

Institution
NICET LEVEL 1 FIRE ALARM SYSTEMS
Course
NICET LEVEL 1 FIRE ALARM SYSTEMS

Document information

Uploaded on
December 29, 2024
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$15.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
NICET 3 FIRE ALARM EXAM, NICET FIRE ALARM LEVEL 1, NICET FIRE ALARM LEVEL 1 PART 1,NICET LEVEL 1 FIRE ALARM SYSTEMS EXAMS BUNDLE
-
4 2025
$ 50.49 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXCELLENCE8HUB Chamberlain School Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
62
Member since
3 year
Number of followers
17
Documents
1597
Last sold
5 days ago
Home of Test Banks , Flash cards, Notes, Exam (elaborations)Questions and Answers.

On this page you find all latest quality Test Banks, Flashcards, notes and examinations (elaborations) you can easily acquire at any place of interest at any comfortable time .Build your knowledge at MED EXCELLENCE HUB. Thank you for your reviews. Growth in knowledge is growth in our future.

4.3

13 reviews

5
10
4
1
3
0
2
0
1
2

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions