B-29 FDNY Exam Questions And Well Elaborated Solutions UPS battery systems that were installed before July 1 200(pre existing systems) shall - ANSWER -Not be required to comply with the design, installation, and ventilation requirements of the 2007 or 2014 fire code. Any better system in place, regardless of installation date, must be under the - ANSWER -General supervision. QUICK visual inspections shall be performed - ANSWER -Once a day The environment for cells should be - ANSWER -Clean, cool, and dry. A UPS room should have what kind of alarm system? - ANSWER -Hydrogen detector. Hazards High voltage electricity -fire -explosion -electrical and high Temperature burns - ANSWER -If any of the above incidents occur, contact 911 immediately. Possible causes of an explosion would be: - ANSWER -Electrolyte Overcharge Safety valve or vents dial due to excess dirt and debris. Hazard Gas release - ANSWER -Explosion Personal injury Hazard Hydrogen gas - ANSWER -Odorless gas Highly flammable (Lower explosion limits 4.0, Upper explosion limits 75.0). Citywide standard key - ANSWER -Also known as a "2642" key Capacity test - ANSWER -A controlled constant current or constant power discharge of a battery to a specified terminal voltage. Fire command center - ANSWER -Where the status of the detection, alarm communications and control systems is displayed, and from which the systems can be manually controlled. Ups battery systems are required to be filed and approved by - ANSWER -The nyc department of buildings COF holders are only allowed to make - ANSWER -Visual inspections UPS systems installed on or after July 1 2008 shall - ANSWER -Comply with the fire code edition in effect at the time they were installed. Central station - ANSWER -A facility that receives alarm signals from a protected premises and retransmits or otherwise reports such alarm signals to the FDNY. Flat charge - ANSWER -A constant potential charge applied to a battery to maintain it in a fully charged condition while minimizing degradation or water consumption. General Supervision - ANSWER -Except as otherwise provided in the fire code, supervision by the holder of any COF who is responsible for performing the duties outlined but need not be personally present on the premises at all times. Key box - ANSWER -A secure device with a lock operable only by a citywide standard key or other approved key. Stationary storage battery - ANSWER -A storage battery designed for use in a stationary installation, in which electrochemical cells are interconnected to supply a nominal voltage of direct current power. Uninterruptible power supply (UPS) - ANSWER -A power supply used to provide alternating current power to a load for some period of time in the event of a power failure UPS system capacity - ANSWER -The ability to deliver power to the load for a specified amount of time, measured in volt- amp (VA). Rated capacity (Lead-Acid) - ANSWER -The capacity assigned to a cell by its manufacturer for a given discharge rate, at a specified electrolyte temperature and specific gravity, to a given end of discharge voltage. Service test - ANSWER -A test of a battery's capability, in "as-found" condition, to satisfy the battery duty cycle. Specific gravity (SG) - ANSWER -The comparison of density compared to water. Thermal runaway - ANSWER -Occurs when more heat is being generated than released, thus causing an increase in temperature of the battery. Battery system anatomy - ANSWER -The process by which a batter creates electricity heavily depends on what kind of battery it is; however, they all have a flow of electricity within each cell called current. Batteries have positive and negative - ANSWER -Electrodes which the current flows between Every battery has a positive and negative plate for? - ANSWER -Rechargeable batteries, the charges on the plates are reversed when the battery is being charged

Show more Read less
Institution
B-29 FDNY
Course
B-29 FDNY









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
B-29 FDNY
Course
B-29 FDNY

Document information

Uploaded on
December 10, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

B-29 FDNY Exam Questions And Well Elaborated
Solutions
UPS battery systems that were installed before July 1 200(pre existing systems)
shall - ANSWER -Not be required to comply with the design, installation, and
ventilation requirements of the 2007 or 2014 fire code.

Any better system in place, regardless of installation date, must be under the -
ANSWER -General supervision.

QUICK visual inspections shall be performed - ANSWER -Once a day

The environment for cells should be - ANSWER -Clean, cool, and dry.

A UPS room should have what kind of alarm system? - ANSWER -Hydrogen
detector.

Hazards

High voltage electricity
-fire
-explosion
-electrical and high Temperature burns - ANSWER -If any of the above incidents
occur, contact 911 immediately.

Possible causes of an explosion would be: - ANSWER -Electrolyte Overcharge
Safety valve or vents dial due to excess dirt and debris.

Hazard

Gas release - ANSWER -Explosion
Personal injury

Hazard

, Hydrogen gas - ANSWER -Odorless gas
Highly flammable
(Lower explosion limits 4.0, Upper explosion limits 75.0).

Citywide standard key - ANSWER -Also known as a "2642" key

Capacity test - ANSWER -A controlled constant current or constant power
discharge of a battery to a specified terminal voltage.

Fire command center - ANSWER -Where the status of the detection, alarm
communications and control systems is displayed, and from which the systems can
be manually controlled.

Ups battery systems are required to be filed and approved by - ANSWER -The
nyc department of buildings

COF holders are only allowed to make - ANSWER -Visual inspections

UPS systems installed on or after July 1 2008 shall - ANSWER -Comply with the
fire code edition in effect at the time they were installed.

Central station - ANSWER -A facility that receives alarm signals from a protected
premises and retransmits or otherwise reports such alarm signals to the FDNY.

Flat charge - ANSWER -A constant potential charge applied to a battery to
maintain it in a fully charged condition while minimizing degradation or water
consumption.

General Supervision - ANSWER -Except as otherwise provided in the fire code,
supervision by the holder of any COF who is responsible for performing the duties
outlined but need not be personally present on the premises at all times.

Key box - ANSWER -A secure device with a lock operable only by a citywide
standard key or other approved key.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamMaestro Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
115
Member since
1 year
Number of followers
5
Documents
3072
Last sold
1 week ago
Exam Vault

Exam Vault is your trusted destination for high-quality exam materials and study resources. We provide a wide rage of tests and prep guides to help you succeed, whether you're preparing for academic exams, certifications, or professional assessments

3.8

13 reviews

5
7
4
2
3
1
2
0
1
3

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions