NCC Electronic Fetal Monitoring Certification (A+ GRADED)Which of the following factors can have a negative effect on uterine blood flow? a. Hypertension b. Epidural c. Hemorrhage d. Diabetes e. All of the above correct answers e. All of the above How does the fetus compensate for decreased maternal circulating volume? a. Increases cardiac output by increasing stroke volume. b. Increases cardiac output by increasing it's heart rate. c. Increases cardiac output by increasing fetal movement. correct answers b. Increases cardiacoutput by increasing it's heart rate. Stimulating the vagus nerve typically produces: a. A decrease in the heart rate b. An increase in the heart rate c. An increase in stroke volume d. No change correct answers a. A decrease in the heart rate What initially causes a chemoreceptor response? a. Epidurals b. Supine maternal position c. Increased CO2 levels d. Decreased O2 levels e. A & C f. A & B g. C & D correct answers g. C & D The vagus nerve begins maturation 26 to 28 weeks. Its dominance results in what effect totheFHR baseline? a. Increases baseline b. Decreases baseline correct answers b. Decreases baseline T/F: Oxygen exchange in the placenta takes place in the intervillous space. correct answers TrueT/F: The parasympathetic nervous system is a cardioaccelerator. correct answers False T/F: Baroreceptors are stretch receptors which respond to increases or decreases in bloodpressure. correct answers True T/F: There are two electronic fetal monitoring methods of obtaining the fetal heart rate: the ultrasound transducer and the fetal spiral electrode. correct answers True ONLYSTUDENTS STORE 2025 ALL THE BEST ONLYSTUDENTS STORE 2 DO NOT COPY T/F: Variability can be determined with the fetoscope. correct answers False T/F: Because the ultrasound transducer and toco transducer are sealed units, they can be dippedin warm water to make cleaning easier. correct answers False T/F: The most common artifact with the ultrasound transducer system for fetal heart rate is increased variability. correct answers True T/F: All fetal monitors contain a logic system designed to reject artifact. correct answers TrueT/F: The monitor should always be tested before starting a tracing, either external or internal mode and labeled a test. correct answers True T/F: The paper speed on the fetal monitor should always be set at 1cm/min. correct answers False T/F: Both internal and external monitoring methods are equally accurate means of obtainingthefetal heart rate and contraction patterns. correct answers False T/F: The external toco is usually placed over the uterine fundus to pick up contractions. correct answers True T/F: The external toco gives measurable uterine pressure. correct answers False T/F: The fetal spiral electrode can be placed when vaginal bleeding of unknown origin is present. correct answers False T/F: The ultrasound transducer is usually placed on the side of the uterus over the baby's back, asthe fetal heart is heard best there. correct answers True T/F: The spiral electrode is used to more accurately determine the frequency, duration, andintensity of uterine contractions. correct answers False T/F: The heart rate from a well-applied fetal spiral electrode can only be fetal, not maternal. correct answers False T/F: The intrauterine catheter is used to pick up the fetal heart rate. correct answers False T/F: The internal spiral electrode may pick up the maternal heart rate if the baby has died. correct answers True T/F: Fetal arrhythmias can be seen on both internal and external monitor tracings. correct answers True ONLYSTUDENTS STORE 2025 ALL THE BEST ONLYSTUDENTS STORE 3 DO NOT COPY T/F: Variability and periodic changes can be detected with both internal and external monitoring. correct answers True T/F: Variable decelerations are a result of cord compression. correct answers True T/F: The presence of FHR accelerations in the intrapartum and antepartum periods is a signof adequate fetal oxygenation. correct answers True T/F: Variable decelerations are a vagal response. correct answers True T/F: Late decelerations have a gradual decrease in FHR (onset to nadir 30 seconds) and are delayed in timing with the nadir of the deceleration occurring after the peak of the contraction. correct answers True T/F: The fetal heart rate baseline can be determined during periods of marked variability. correct answers False T/F: Anything that affects maternal blood flow (cardiac output) can affect the blood flowthroughthe placenta. correct answers True T/F: Variable decelerations are the most frequently seen fetal heart rate deceleration patterninlabor. correct answers True T/F: Minimal variability is always an indicator of hypoxia and a Cesarean section is indicated. correct answers False What is your first intervention in management of a patient experiencing variable decelerations?a. Immediate delivery b. Change maternal position c. No treatment indicated d. Oxygen e. Stop oxytocin infusion correct answers b. Change maternal position Etiology of a baseline FHR of 165bpm occurring for the last hour can be: 1. Maternal supine hypotension 2. Maternal fever 3. Maternal dehydration 4. Unknown a. 1 and 2 b. 1, 2 and 3 c. 2, 3 and 4 correct answers c. 2, 3 and 4 What is the most probable cause of recurrent late decelerations? a. Utero-placental insufficiency b. Head compression c. Cord compression ONLYSTUDENTS STORE 2025 ALL THE BEST ONLYSTUDENTS ST

Content preview

ONLYSTUDENTS STORE 2025 ALL THE BEST




NCC Electronic Fetal Monitoring Certification (A+
GRADED)
Which of the following factors can have a negative effect on uterine blood flow?
a. Hypertension
b. Epidural
c. Hemorrhage
d. Diabetes
e. All of the above correct answers e. All of the above

How does the fetus compensate for decreased maternal circulating volume?
a. Increases cardiac output by increasing stroke volume.
b. Increases cardiac output by increasing it's heart rate.
c. Increases cardiac output by increasing fetal movement. correct answers b. Increases cardiac
output by increasing it's heart rate.

Stimulating the vagus nerve typically produces:
a. A decrease in the heart rate
b. An increase in the heart rate
c. An increase in stroke volume
d. No change correct answers a. A decrease in the heart rate

What initially causes a chemoreceptor response?
a. Epidurals
b. Supine maternal position
c. Increased CO2 levels
d. Decreased O2 levels
e. A & C
f. A & B
g. C & D correct answers g. C & D

The vagus nerve begins maturation 26 to 28 weeks. Its dominance results in what effect to the
FHR baseline?
a. Increases baseline
b. Decreases baseline correct answers b. Decreases baseline

T/F: Oxygen exchange in the placenta takes place in the intervillous space. correct answers True

T/F: The parasympathetic nervous system is a cardioaccelerator. correct answers False

T/F: Baroreceptors are stretch receptors which respond to increases or decreases in blood
pressure. correct answers True

T/F: There are two electronic fetal monitoring methods of obtaining the fetal heart rate: the
ultrasound transducer and the fetal spiral electrode. correct answers True
ONLYSTUDENTS STORE 1 DO NOT COPY

,ONLYSTUDENTS STORE 2025 ALL THE BEST




T/F: Variability can be determined with the fetoscope. correct answers False

T/F: Because the ultrasound transducer and toco transducer are sealed units, they can be dipped
in warm water to make cleaning easier. correct answers False

T/F: The most common artifact with the ultrasound transducer system for fetal heart rate is
increased variability. correct answers True

T/F: All fetal monitors contain a logic system designed to reject artifact. correct answers True

T/F: The monitor should always be tested before starting a tracing, either external or internal
mode and labeled a test. correct answers True

T/F: The paper speed on the fetal monitor should always be set at 1cm/min. correct answers
False

T/F: Both internal and external monitoring methods are equally accurate means of obtaining the
fetal heart rate and contraction patterns. correct answers False

T/F: The external toco is usually placed over the uterine fundus to pick up contractions. correct
answers True

T/F: The external toco gives measurable uterine pressure. correct answers False

T/F: The fetal spiral electrode can be placed when vaginal bleeding of unknown origin is present.
correct answers False

T/F: The ultrasound transducer is usually placed on the side of the uterus over the baby's back, as
the fetal heart is heard best there. correct answers True

T/F: The spiral electrode is used to more accurately determine the frequency, duration, and
intensity of uterine contractions. correct answers False

T/F: The heart rate from a well-applied fetal spiral electrode can only be fetal, not maternal.
correct answers False

T/F: The intrauterine catheter is used to pick up the fetal heart rate. correct answers False

T/F: The internal spiral electrode may pick up the maternal heart rate if the baby has died. correct
answers True

T/F: Fetal arrhythmias can be seen on both internal and external monitor tracings. correct
answers True


ONLYSTUDENTS STORE 2 DO NOT COPY

,ONLYSTUDENTS STORE 2025 ALL THE BEST



T/F: Variability and periodic changes can be detected with both internal and external monitoring.
correct answers True

T/F: Variable decelerations are a result of cord compression. correct answers True

T/F: The presence of FHR accelerations in the intrapartum and antepartum periods is a sign of
adequate fetal oxygenation. correct answers True

T/F: Variable decelerations are a vagal response. correct answers True

T/F: Late decelerations have a gradual decrease in FHR (onset to nadir 30 seconds) and are
delayed in timing with the nadir of the deceleration occurring after the peak of the contraction.
correct answers True

T/F: The fetal heart rate baseline can be determined during periods of marked variability. correct
answers False

T/F: Anything that affects maternal blood flow (cardiac output) can affect the blood flow through
the placenta. correct answers True

T/F: Variable decelerations are the most frequently seen fetal heart rate deceleration pattern in
labor. correct answers True

T/F: Minimal variability is always an indicator of hypoxia and a Cesarean section is indicated.
correct answers False

What is your first intervention in management of a patient experiencing variable decelerations?
a. Immediate delivery
b. Change maternal position
c. No treatment indicated
d. Oxygen
e. Stop oxytocin infusion correct answers b. Change maternal position

Etiology of a baseline FHR of 165bpm occurring for the last hour can be:
1. Maternal supine hypotension
2. Maternal fever
3. Maternal dehydration
4. Unknown
a. 1 and 2
b. 1, 2 and 3
c. 2, 3 and 4 correct answers c. 2, 3 and 4

What is the most probable cause of recurrent late decelerations?
a. Utero-placental insufficiency
b. Head compression
c. Cord compression
ONLYSTUDENTS STORE 3 DO NOT COPY

, ONLYSTUDENTS STORE 2025 ALL THE BEST



d. Maternal position change correct answers a. Utero-placental insufficiency

The most prevalent risk factor associated with fetal death before the onset of labor is:
a. Low socioeconomic status
b. Fetal malpresentation
c. Uteroplacental insufficiency
d. Uterine anomalies correct answers c. Uteroplacental insufficiency

Which of the following is NOT used for antepartum fetal surveillance?
a. Fetal movement counting
b. Antepartum fetal heart rate testing
c. Biophysical profile testing
d. Maternal HCG levels correct answers d. Maternal HCG levels

Which of the following conditions is not an indication for antepartum fetal surveillance?
a. Gestational hypertension
b. Diabetes in pregnancy
c. Fetus in breech presentation
d. Decreased fetal movement correct answers c. Fetus in breech presentation

Which of the following does not affect the degree of fetal activity?
a. Vibroacoustic stimulation
b. Smoking
c. Fetal position
d. Gestational age correct answers a. Vibroacoustic stimulation

To be considered reactive, a nonstress test must have:
a. 4 fetal heart rate accelerations in a 20 minute window
b. 2 fetal heart rate accelerations in a 10 minute window
c. 4 fetal heart rate accelerations in a 40 minute window
d. 2 fetal heart rate accelerations in a 20 minute window correct answers d. 2 fetal heart rate
accelerations in a 20 minute window

If a nonstress test is nonreactive after 40 minutes, the next step should be:
a. Have the client go home and do fetal movement counts
b. Do a biophysical profile or contraction stress test
c. Repeat the nonstress test within a week
d. Admit the client for delivery correct answers b. Do a biophysical profile or contraction stress
test

All of the following are components of a biophysical profile except:
a. Contraction stress test
b. Assessment of fetal breathing
c. Amniotic fluid volume measurement
d. Fetal movement assessment correct answers a. Contraction stress test

ONLYSTUDENTS STORE 4 DO NOT COPY

Document information

Uploaded on
December 5, 2024
Number of pages
56
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Onlystudents
3.9
(19)
Sold
111
Followers
86
Items
1355
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions