Answers
Which resistance should an earth electrode subsystem bond not exceed Correct Ans-1
milliohm
what is the only bond that can be made with soft solder Correct Ans-signal reference bond
although power leaked by a cable may be a very small percentage of transmitted power, it could
still cause Correct Ans-significant interference to sensitive circuits
why is evaluating all conductive paths for the escape of compromising emanations difficult
Correct Ans-there are so many of them
as a result of which process are electrical charges developed Correct Ans-friction
what is not a source of static electricity Correct Ans-grounded work bench
what is the best method for controlling ESD Correct Ans-prevent them from building up
Which ESD preventative measure can be used without actually making contact with an item
Correct Ans-ionizing blower
, the type of terrain RAWS should be sited on is flat and Correct Ans-unobstructed
the maximum surface roughness for area A of the localizer Correct Ans-must not exceed +/-
0.5 ft
The distance around the localizer that must be free from reflecting objects, such as buildings,
power lines, wire-mesh fences, trees, or parked aircraft is a Correct Ans-500 ft radius from
the center of the course array
how many feet must vehicular traffic be in front of glideslope equipment Correct Ans-500 ft
what is the maximum distance in feet between the AN/TPS-75 antenna pallet and the equipment
shelter Correct Ans-21 ft
when siting for the AN/TPN-19, what is the maximum separation distance in miles between the
operations and radar shelters Correct Ans-10 mi
as good practice, what general items should be inspected in RAWS facilities and on remote
equipment during normally scheduled PMI's` Correct Ans-corrosion, equipment racks,
animals and insects, and environmental considerations
the action aircrews perform when a navigation system's identification is not received or the
identification code is set to "T E S T" is Correct Ans-consider the signal unreliable