WASTEWATER CLASSBTEXASEXAM2025 WITH 100%CORRECTANSWERSThe name of the State Agency responsible for enforcing pollution control laws in Texas - correct answer Texas Commission of Environmental Quality The term pathogenic means - correct answer Capable of causing disease The minimum separation between sewer lines and potable water lines is - correct answer 9 feet A licensed wastewater operator is a professional - correct answer consistently does best jobpossible, practices personal safety, strives to improve job knowledge, strives to keep the plant andcollection system in the best appearance and working order An important step in testing a sample for Total Suspended Solids is - correct answer Filtering asample The Biochemical oxygen Demand (BOD) of a sample is based on - correct answer Measuring thedissolved oxygen (DO) used The results of Biochemical Oxygen Demand (BOD) sample taken at a treatment plant tells the operator - correct answer How the plant was operating 5 days ago Which of the following are dangerous gasses that are likely to be present in lift stations and manholes?- correct answer Natural gas, gasoline fumes, hydrogen sulfide and carbon dioxide A preferred hydraulic method of cleaning sewer lines is - correct answer Hydro Jet Cleaner ONLYSTUDENT STORE 2025 ALL THE BEST ONLYSTUDENT STORE 2 DO NOT COPY Ways to reduce bad odors coming from a collection system - correct answer routinely cleaningslowrunning or low flow lines, adding chlorine or hydrogen peroxide to the collection systemTypes of pipe that are commonly used in wastewater collection system - correct answer ductileiron, Poly Vinyl Chloride (PVC) Before entering a confined space a worker should - correct answer Use approved monitoring deviceand check for the presence of dangerous gasses, ventilate the space with a blower, wear a safety harness and attach a life line A properly designed and operated primary sedimentation tank should remove _____ percent of incoming BOD - correct answer 30-40% Devices that may be used to determine the level of sewage in a lift station - correct answer air bubbler, floats, electrodes, Acoustic (sonic) What is the most important role of aerobic bacteria in the treatment of wastewater? - correct answer decompose organic matter The hydraulic loading of a trickling filter may be determined by - correct answer flowrate andfilter area These can be used to dewater sludge - correct answer belt press, drying beds, solid bowl centrifuge, gravity thickener Most important to providing adequate sewage treatment in a stabilization pond - correct answer sunlight, algae, bacteria and time Offensive and objectionable odors which sometimes occur in trickling filters usually indicate - correct answer septic conditions are present ONLYSTUDENT STORE 2025 ALL THE BEST ONLYSTUDENT STORE 3 DO NOT COPY Dissolved Oxygen (DO) in aeration tank of an activated sludge plant should be maintained at or about - correct answer 2 to 4 mg/L Contributes to the infiltration in a collection system - correct answer breaks in the main lines, highground water levels, heavy rains, hydro jet cleaning plugged mains When a centrifuge pump loses prime the - correct answer pump is no longer moving liquid A Rotating Biological Contactor (RBC) is - correct answer fixed firm biological treatment process Needs to be checked regularly to properly operate an activated sludge treatment plant - correct answer aeration equipment and mixed liquor solids Point source discharges are - correct answer discharges that come from pipes or ditches that aremonitored, controlled and inspected Non-point discharges are - correct answer discharges that have intermittent, dispersed flows having little or no contro

Content preview

ONLYSTUDENT STORE 2025 ALL THE BEST




WASTEWATER CLASS B TEXAS EXAM
2025 WITH 100% CORRECT ANSWERS

The name of the State Agency responsible for enforcing pollution control laws in Texas - correct answer
✔✔Texas Commission of Environmental Quality



The term pathogenic means - correct answer ✔✔Capable of causing disease



The minimum separation between sewer lines and potable water lines is - correct answer ✔✔9 feet



A licensed wastewater operator is a professional - correct answer ✔✔consistently does best job
possible, practices personal safety, strives to improve job knowledge, strives to keep the plant and
collection system in the best appearance and working order



An important step in testing a sample for Total Suspended Solids is - correct answer ✔✔Filtering a
sample



The Biochemical oxygen Demand (BOD) of a sample is based on - correct answer ✔✔Measuring the
dissolved oxygen (DO) used



The results of Biochemical Oxygen Demand (BOD) sample taken at a treatment plant tells the operator -
correct answer ✔✔How the plant was operating 5 days ago



Which of the following are dangerous gasses that are likely to be present in lift stations and manholes? -
correct answer ✔✔Natural gas, gasoline fumes, hydrogen sulfide and carbon dioxide



A preferred hydraulic method of cleaning sewer lines is - correct answer ✔✔Hydro Jet Cleaner




ONLYSTUDENT STORE 1 DO NOT COPY

,ONLYSTUDENT STORE 2025 ALL THE BEST



Ways to reduce bad odors coming from a collection system - correct answer ✔✔routinely cleaning slow
running or low flow lines, adding chlorine or hydrogen peroxide to the collection system



Types of pipe that are commonly used in wastewater collection system - correct answer ✔✔ductile
iron, Poly Vinyl Chloride (PVC)



Before entering a confined space a worker should - correct answer ✔✔Use approved monitoring device
and check for the presence of dangerous gasses, ventilate the space with a blower, wear a safety
harness and attach a life line



A properly designed and operated primary sedimentation tank should remove _____ percent of
incoming BOD - correct answer ✔✔30-40%



Devices that may be used to determine the level of sewage in a lift station - correct answer ✔✔air
bubbler, floats, electrodes, Acoustic (sonic)



What is the most important role of aerobic bacteria in the treatment of wastewater? - correct answer
✔✔decompose organic matter



The hydraulic loading of a trickling filter may be determined by - correct answer ✔✔flow rate and filter
area



These can be used to dewater sludge - correct answer ✔✔belt press, drying beds, solid bowl centrifuge,
gravity thickener



Most important to providing adequate sewage treatment in a stabilization pond - correct answer
✔✔sunlight, algae, bacteria and time



Offensive and objectionable odors which sometimes occur in trickling filters usually indicate - correct
answer ✔✔septic conditions are present




ONLYSTUDENT STORE 2 DO NOT COPY

, ONLYSTUDENT STORE 2025 ALL THE BEST



Dissolved Oxygen (DO) in aeration tank of an activated sludge plant should be maintained at or about -
correct answer ✔✔2 to 4 mg/L



Contributes to the infiltration in a collection system - correct answer ✔✔breaks in the main lines, high
ground water levels, heavy rains, hydro jet cleaning plugged mains



When a centrifuge pump loses prime the - correct answer ✔✔pump is no longer moving liquid



A Rotating Biological Contactor (RBC) is - correct answer ✔✔fixed firm biological treatment process



Needs to be checked regularly to properly operate an activated sludge treatment plant - correct answer
✔✔aeration equipment and mixed liquor solids



Point source discharges are - correct answer ✔✔discharges that come from pipes or ditches that are
monitored, controlled and inspected



Non-point discharges are - correct answer ✔✔discharges that have intermittent, dispersed flows
having little or no control



The Texas Water Code establishes the protection of water quality and quantity of the state by - correct
answer ✔✔setting stream standards, issues permits for discharges, identifies non-point source controls,
and establishes water reuse.



The wastewater plant operator is primarily responsible for - correct answer ✔✔treating wastewater
discharged into the community



Chapter ___ of the Texas Water Code is the state law controlling water pollution and ___ authority to
control discharges in Texas - correct answer ✔✔Chapter 26 and Texas Commission of Environmental
Quality



The Texas Commission on Environmental Quality can revoke an operator's license if the operator -
correct answer ✔✔causes permit violation, falsifies records or neglects their duty
ONLYSTUDENT STORE 3 DO NOT COPY

Document information

Uploaded on
December 4, 2024
Number of pages
18
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Onlystudents
3.9
(19)
Sold
111
Followers
86
Items
1355
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions