2024update|Elevator Mechanic Exam
Review|Comprehensive questions and verified
answers/accurate solutions|Get it 100% correct!!
Already graded A+
Practice questions for this set
Learn 1 /7 Study with Learn
Diam=12" 12/4=3" 25fpm=3" 100fpm + 25fpm= 12"+3"= 15" sheave
Give this one a try later!
A contractor wants to raise the car
There is slight arcing between the
speed from 100fpm to 125fpm, it
2 brush and commutator. What
currently has a 12" sheave. What
action must be taken?
sheave is required?
You notice Roughing on the Gov In order to properly bond an
3 and Tail Sheave. What should you 4 isolation platform, where should
check? you connect your bonding straps?
Don't know?
Terms in this set (216)
https://quizlet.com/979005718/2024updateelevator-mechanic-exam-reviewcomprehensive-questions-and-verified-answersaccurate-solutionsget-… 1/12
, 12/3/24, 7:31 AM 2024update|Elevator Mechanic Exam Review|Comprehensive questions and verified answers/accurate solutions|Get it 100% c…
A contractor wants to Diam=12" 12/4=3" 25fpm=3" 100fpm + 25fpm= 12"+3"=
raise the car speed from 15" sheave
100fpm to 125fpm, it
currently has a 12" sheave.
What sheave is required?
A MOV (Metal Oxide Replace it with a larger MOV
Varistor) burns out. You
replace it, but cannot
read voltage or
resistance. What should
you do?
On a Ward-Leonard Suicide Circuit
circuit the break is set,
but the motor is trying to
slip through the break.
What is the issue?
You have an old DC Leave the interpoles alone. When adding a SCR
motor and are adding an drive to the generator, the series loop is removed,
SCR drive, what do you as are the 3 resistors. Everything else remains the
do to the interpoles? same
A hydro runs up with no The relief valve is set too low
load, but will not run with
a full load. What is the
issue?
Runby for a 1:1 hits the 22"
CWT buffer 4" below the
top landing. CWT runby
should be set at 18". How
much should the ropes
be shortened?
You need to work on a Door Operator Disconnect/ Main Line Disconnect
freight door retiring cam,
you LOTO the main line
but there is still power on
the cam. What circuit is
still hot?