100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

EPA 608 TYPE 1 TEST EXAM|| LATELY UPDATED 210 QUESTIONS AND 100% CORRECT ANSWERS ALREADY GRADED A+|| LATEST AND COMPLETE UPDATE WITH VERIFIED SOLUTIONS|| ASSURED PASS!!!

Rating
-
Sold
-
Pages
32
Grade
A+
Uploaded on
20-11-2024
Written in
2024/2025

EPA 608 TYPE 1 TEST EXAM|| LATELY UPDATED 210 QUESTIONS AND 100% CORRECT ANSWERS ALREADY GRADED A+|| LATEST AND COMPLETE UPDATE WITH VERIFIED SOLUTIONS|| ASSURED PASS!!!

Institution
EPA 608 TYPE 1
Module
EPA 608 TYPE 1











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA 608 TYPE 1
Module
EPA 608 TYPE 1

Document information

Uploaded on
November 20, 2024
Number of pages
32
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

1|Pag e


EPA 608 TYPE 1 TEST EXAM|| 2024-2025 LATELY
UPDATED 210 QUESTIONS AND 100% CORRECT
ANSWERS ALREADY GRADED A+|| LATEST AND
COMPLETE UPDATE 2024-2025 WITH VERIFIED
SOLUTIONS|| ASSURED PASS!!!
Recovery equipemnt used for the service or repair of small appliances must be
certified by an EPA approved lab if the recovery equipment was made after -
ANSWER: November 15, 1993




Recovery devices made before 11-15-93 and are used for recovery of refrigerant
from small appliances must be capable of: - ANSWER: recovering 80% of the
refrigerant whether or not the compressor is operating or achieving a 4 inch
vacuum under conditions of ARI 740-1993




EPA's definition of a small appliance includes: - ANSWER: a device
manufactored, charges & hermeticly sealed in factory with a charge of 5lbs or less




Tech's with a type 1 small appliance certification are certified to recover refrigerant
during the maintenance or repair of: - ANSWER: PTAC's with 5lbs or less of
refrigerant




EPA requires that all small appliances be equipped with a service aperture or other
device that is used when adding or removing refrigerant from the appliance. For
small appliances this service port typically - ANSWER: a straight piece of tubing,
called a process tube that is entered using a piercing valve

,2|Pag e




The EPA section 608 certification must be renewed every - ANSWER: never




It is an EPS regulation that any person who opens and appliance for maintenance,
service or repair must have at least one self-contained recovery machine avalible at
their place of buisiness. The only exception to this rule are persons working on -
ANSWER: small appliances




The sale od CFC & HCFC refrigerants is: - ANSWER: restricted to techs who are
EPA certified in refrigerant recovery




Anyone who recovers refrigeration during maintenance, service or repair of small
appliances must be certified as either a universal Tech or a: - ANSWER: Type 1
tech




When recovering refrigerant from a household refrigerator who's compressor does
not run, it is recommended that a low and high side access valves be installed
because: - ANSWER: it can help speed of recovery and required recovery effiency




If you install an access fitting into a sealed system: - ANSWER: the fitting should
be leak tested before proceeding with recovery

,3|Pag e




Before beginning a refrigerant recovery procedure it is alway necessary to: -
ANSWER: determine the type of refrigerant in the system




when recovering refrigerant into a non-pressurized container from a refrigerator
with an improper compressor: - ANSWER: it is necessary to heat & strike the
compressor with a rubber mallet




When checking for the existence of noncondensable gases inside a recovery
cyclinder, why is it proper procedure to allow the temperature of the cyclinder to
stabilize @ room temperature before taking a pressure reading? - ANSWER: any
comparisons to a pressure-temperature chart is only valid if both the pressure &
temperature of the refrigerant are stable




A recovery cyclinder which is 1/2 full of recovered R-410A @ 90*F, in the
absence of non-condensables will be presurized to: - ANSWER: 300 psig.




When using , it is essential to take extra measures (heating/striking), to help
release trapped refrigerant from the compressor oil. - ANSWER: passive system-
dependdent recovery devices on a small appliance with a non-operating
compressor.




According to the EPA which recovery equipment maintenance practice(s) should
be preformed on a regular basis? - ANSWER: check recovery device for
refrigerant leaks

, 4|Pag e




On a small appliance with an operating compressor that has a completely plugged
capillary tube, what is the minimum number of access valves that are needed to
evacuate the refrigerant - ANSWER: 1 valve on the high side


Which refrigerant is most commonly used as a replacement for R-12 in new
household refrigerators - ANSWER: R-134a




Small amounts of refrigerant have no odor, therefor a pungent odor is detected
during a system recovery &/or repair: - ANSWER: a compressor burn-out has
likely occurred




If R-22 or R-12are exposed to high temperatures, these refrigerants can decompose
to form: - ANSWER: hydrochloric & hydroflouric acids




Large spills of refrigerant can cause suffocation because: - ANSWER: they are
heavier than air & displace oxygen




In the event of a large release of R-12 or R-22 in a contained area - ANSWER:
you should wear a "SCBA" or leave the area is required

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
tutorlincon Walden University
View profile
Follow You need to be logged in order to follow users or courses
Sold
748
Member since
2 year
Number of followers
24
Documents
4163
Last sold
4 days ago
YOUR TRUSTWORTHY SOURCE FOR HIGH-IMPACT STUDY MATERIALS, GOLD RATED TOP NOTCH SELLER REPETITIVELY KNOWN FOR OFFERING BEST STUDY MATERIALS.

Unlock your academic success with our comprehensive study documents (EXAMS, CASE STUDY, STUDY GUIDES, NOTES ETC.) Here, you’ll find: • Comprehensive Guide to U.S. Certification & Licensing Exams • All-in-One Directory of U.S. Professional Certification Exams • United States Certification & Licensing Exams Master List • National Certification Exams Index: All U.S. Professions • Complete U.S. Credentialing & Certification Exam Catalog Specialized Nursing Exam Resources: • Up-to-date exams and assignments • Detailed test banks with verified questions and answers • Elaborate exam solutions • Case studies and discussion-based content Customized package deals are available to suit your specific needs. Do you want better outcomes? Obtain well-prepared resources that are effective. Feeling overburdened by the pressure of exams? Our goal is to make things easier. With the aid of our study guides, you can maintain concentration, boost your self-esteem, and arrive to tests ready. Made from actual previous exams, they show you the kinds of questions you'll encounter and how to answer them effectively, allowing you to prepare more effectively and improve your marks. pick us because; we are Stuvia Gold-rated vendors by 950+ happy students; get Reliable resources for certification and healthcare achievement; Support that is responsive and kind when you need it.

Read more Read less
4.4

395 reviews

5
249
4
81
3
50
2
9
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions