Geschrieben von Student*innen, die bestanden haben Sofort verfügbar nach Zahlung Online lesen oder als PDF Falsches Dokument? Kostenlos tauschen 4,6 TrustPilot
logo-home
Document preview thumbnail
Vorschau 1 aus 4 Seiten
Prüfung

FOA- Fiber Optic Certification Exam T/F

Document preview thumbnail
Vorschau 1 aus 4 Seiten

50/125 microns represents a single mode fiber size - answer-False- Single mode fiber is 8/10 microns Cable that is resistant to water damage is - answer-loose tube Composite cables have only fiber - answer-false- they also have copper Connector - answer-non permanent connections Damage to fiber optic cable caused by excessive pulling can be reversed by sending the cable back to the factory. True Or False? - answer-False Distribution cables use mass fusion splicing - answer-False- Ribbion cable uses mass fusion double-stick tape can be used for - answer-collecting and disposing of bare fiber ends. fiber is pulled on the? - answer-Strength Member Fiber optic joints should have - answer-low loss and high mechanical strength For long cable pulls, - answer-the pull should be split up into two or more stages. For safety, all fiber optic work areas must - answer-have sufficient work space Fusion Splicers should not be used - answer-in places that may contain flammable gasses Fusion splicing - answer-permanent singlemode connection In graded index multi mode fiber, does the light travel faster near the center or the outside of the core? Why? - answer-Travels faster outside because the slight change in glass type in order for all rays of light to reach the end at the same time. Installed fiber must be - answer-documented, tested, and terminated correctly. instrument for checking continuity fiber tracing - answer-visual fault locator instrument for checking duplex connector polarity - answer-visual fiber tracer instrument for connector faults such as dirt scratches - answer-Inspection microscope instrument for fault location, splice loss - answer-OTOR graph instrument for insertion loss - answer-Light source and power meter instrument for source or receiver power - answer-power meter Large core step-index is the most common in plastic optical fiber - answer-True List five causes of attenuation in fiber optic connections. - answer-Cores don't line up, NA Miss-Match/wrong patch cord, Dirt on connector, Under polished, End Angle, End Gap, Coaxiality, Axial Run-out, Concentricity, Core ellipticity. List five steps for a mechanical connector installation. - answer-Strip Wire, Clean, Cleave, insert and lock in place, Test. List the Color Code in Order. - answer-Blue Orange Green Brown Slate White Red Black Yellow Violet Rose Aqua List the tools and supplies required for preparation of the ends of tight buffer tube cables. - answer-Razer, strippers, scissor, glasses, closed toe shoes, tape, rubber mat, sufficient work space. Loose tube may require the instalation of what - answer-Breakout kit mechanical splicing - answer-restoration or multimode joints Most singlemode field terminations are made by - answer-fusion splicing a factory pigtail onto the cable Multimode Fiber has a greater bandwidth than single mode fiber - answer-False - Single mode has less dispersion: more bandwidth No fiber optic cable needs to be grounded - answer-False - any electronic material must be grounded Orange cable contains multimode fiber - answer-True Outside cable resistant to rodents - answer-Armored cable Pulling from the center to the ends is a way of pulling long cables in conduits - answer-True Single mode fiber cables are usally color coded in gray - answer-Fase - Yellow Telcom Fttx is typically - answer-single mode fiber Telecom FTTx is typically single mode fiber - answer-True The cable that is used indoors in air handling areas is - answer-plenum rated cable The cladding is the portion of the fiber you are removing during stripping - answer-The buffer is what you take off The most important safety concern specific to fiber optics is? - answer-Shards of bare fibers getting stuck in skin or eyes. The reference cables that are used during testing must be chosen for their low loss characteristics - answer-True The testing phase of a project is when you do loss/budget anaylisis - answer-False - should be done in the planning stage Unit for measuring absoulute power - answer-dBm Unit for measuring bandwidth - answer-GHz Unit for measuring cable length is - answer-Feet or meters

Inhaltsvorschau

FOA- Fiber Optic Certification Exam T/F
50/125 microns represents a single mode fiber size - answer-False- Single mode
fiber is 8/10 microns

Cable that is resistant to water damage is - answer-loose tube

Composite cables have only fiber - answer-false- they also have copper

Connector - answer-non permanent connections

Damage to fiber optic cable caused by excessive pulling can be reversed by sending
the cable back to the factory. True Or False? - answer-False

Distribution cables use mass fusion splicing - answer-False- Ribbion cable uses mass
fusion

double-stick tape can be used for - answer-collecting and disposing of bare fiber
ends.

fiber is pulled on the? - answer-Strength Member

Fiber optic joints should have - answer-low loss and high mechanical strength

For long cable pulls, - answer-the pull should be split up into two or more stages.

For safety, all fiber optic work areas must - answer-have sufficient work space

Fusion Splicers should not be used - answer-in places that may contain flammable
gasses

Fusion splicing - answer-permanent singlemode connection

In graded index multi mode fiber, does the light travel faster near the center or the
outside of the core? Why? - answer-Travels faster outside because the slight change
in glass type in order for all rays of light to reach the end at the same time.

Installed fiber must be - answer-documented, tested, and terminated correctly.

instrument for checking continuity fiber tracing - answer-visual fault locator

instrument for checking duplex connector polarity - answer-visual fiber tracer

instrument for connector faults such as dirt scratches - answer-Inspection
microscope

instrument for fault location, splice loss - answer-OTOR graph

instrument for insertion loss - answer-Light source and power meter

Dokument Information

Hochgeladen auf
19. november 2024
Anzahl der Seiten
4
geschrieben in
2024/2025
Typ
Prüfung
Enthält
Fragen & antworten
$10.99

Falsches Dokument? Kostenlos tauschen Innerhalb von 14 Tagen nach dem Kauf und vor dem Herunterladen kannst du ein anderes Dokument wählen. Du kannst den Betrag einfach neu ausgeben.
Geschrieben von Student*innen, die bestanden haben
Sofort verfügbar nach Zahlung
Online lesen oder als PDF

Seller avatar
Bewertungen des Ansehens basieren auf der Anzahl der Dokumente, die ein Verkäufer gegen eine Gebühr verkauft hat, und den Bewertungen, die er für diese Dokumente erhalten hat. Es gibt drei Stufen: Bronze, Silber und Gold. Je besser das Ansehen eines Verkäufers ist, desto mehr kannst du dich auf die Qualität der Arbeiten verlassen.
TOPDOCTOR
5.0
(1)
Verkauft
10
Anhänger
5
Sachen
3390
Zuletzt verkauft
10 Jahren vor


Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Arbeitest du an deiner Quellenangabe?

Erstelle korrekte Quellenangaben in APA, MLA und Harvard mit unserem kostenlosen Zitiergenerator.

Arbeitest du an deiner Quellenangabe?

Häufig gestellte Fragen