©BRIGHTSTARS EXAM SOLUTIONS 11/14/2024 12:19 PM 1 | P a g e Electrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits. Exam Questions With Verified Answers According to the NEC®, the ampacity of branch circuit conductors must be derated when there are more than how many current-carrying conductors in a raceway? - answer3 Air conditioning overcurrent protective devices can never exceed what percentage of the motor-rated load current or the branch circuit selection current (whichever is greater)? - answer225% Conductors must be derated when installed in conduit - answeron or above rooftops Continuous loads are calculated at what percentage of the maximum current rating of the overcurrent device? - answer80% For a given load and length, the branch circuit voltage drop should not exceed - answer3% For resistance welders, the rating for the overcurrent protection device should not exceed what percentage of the primary current rating of the welder? - answer300% Show window lighting is calculated at 200VA per linear foot plus - answer125% The allowable ampacity for eleven No. 12 THHN copper conductors in a cable must be adjusted by - answer50% The load for 10' of multi-outlet assembly used to supply several loads simultaneously is - answer1,800VA The maximum size dual-element fuse for a 40hp, 3Ø, 460V motor with a Design Letter D is - answer100A What is the demand load for one household range with a nameplate rating of 11.75kW, 240V, 1Ø? - answer8kW

Show more Read less
Institution
Load Calculations
Course
Load Calculations








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Load Calculations
Course
Load Calculations

Document information

Uploaded on
November 18, 2024
Number of pages
3
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

©BRIGHTSTARS EXAM SOLUTIONS

11/14/2024 12:19 PM


Electrical Level 3 Module 1 Load
Calculations and Branch Feeder Circuits.
Exam Questions With Verified Answers


According to the NEC®, the ampacity of branch circuit conductors must be derated when there
are more than how many current-carrying conductors in a raceway? - answer✔3
Air conditioning overcurrent protective devices can never exceed what percentage of the
motor-rated load current or the branch circuit selection current (whichever is greater)? -
answer✔225%

Conductors must be derated when installed in conduit - answer✔on or above rooftops
Continuous loads are calculated at what percentage of the maximum current rating of the
overcurrent device? - answer✔80%

For a given load and length, the branch circuit voltage drop should not exceed - answer✔3%
For resistance welders, the rating for the overcurrent protection device should not exceed what
percentage of the primary current rating of the welder? - answer✔300%

Show window lighting is calculated at 200VA per linear foot plus - answer✔125%
The allowable ampacity for eleven No. 12 THHN copper conductors in a cable must be adjusted
by - answer✔50%
The load for 10' of multi-outlet assembly used to supply several loads simultaneously is -
answer✔1,800VA
The maximum size dual-element fuse for a 40hp, 3Ø, 460V motor with a Design Letter D is -
answer✔100A
What is the demand load for one household range with a nameplate rating of 11.75kW, 240V,
1Ø? - answer✔8kW



1|Page

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brightstars Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
193
Member since
1 year
Number of followers
7
Documents
12191
Last sold
4 days ago
VERIFIED EXAMS AND STUDY GUIDES.

Here, you will find Study Notes, Exam answer packs 100% Guarenteed success.

3.3

31 reviews

5
10
4
4
3
8
2
3
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions