100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

National Electrical Code Exam Questions with Verified Solutions (Graded A+)

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
13-11-2024
Written in
2024/2025

National Electrical Code Exam Questions with Verified Solutions (Graded A+) load calculations must be performed in order to determine the _ - Answers size of services and feeders a feeder is defined as all circuit conductors between the _ containing fuses or breakers that feed branch circuits - Answers service disconnecting means and the panelboard _ are not included in the calculated floor area of a dwelling unit - Answers open porches a scale ruler is used in _ - Answers determining the location of outlets the _ is not an important piece of information to gather before performing load calculations - Answers location of circuit breakers the _, including the strip heat and blower motor, is necessary information for calculating loads - Answers total volt-ampere load the lighting load for residential dwelling unit is _ volt-amperes per square foot - Answers 3 the _ for each floor of a one family dwelling shall be computed using the outside dimensions - Answers floor area _must be included when calculating a dwelling unit service - Answers small appliance branch circuits a dwelling unit must have at least _ small appliance branch circuits - Answers 2 each laundry branch circuit is calculated at - Answers no less than 1500 volt amperes individual household cooking appliances rated more than _ watts (volt-amperes) can be derated using Table 220.55 demand factors (and all applicable notes) - Answers 1750 no derating is allowed when there are only 1, 2, or 3 appliances - Answers fastened in place the term _ designates utilization equipment commonly built in standardized types and sizes and installed as a unit to perform specific functions - Answers appliance a clothes dryer neutral load on a feeder can be calculated at _ % - Answers 70 multiplying voltage by amperage produces - Answers volt-amperes (VA) horsepower ratings must be converted to _ before they can be added to the load calculation form - Answers volt amperes (VA) the smaller of the two (or more) _ loads can be omitted as long as they are never energised simultaneously - Answers noncoincident fur the purpose of the standard method load calculation for a one family dwelling, the terms neutral and _ are synonymous - Answers grounded a demand factor of _ % can be applied to the nameplate rating load of four or more fastened in place appliances - Answers 75 in outdoor applications _ grounding electrode conductors must not be installed within 18 inches of the earth - Answers aluminum _ are not included in calculating receptacle loads for appliances - Answers air conditioning systems the exact nameplate rating of the clothes dryer, even if less than _ volt amperes should be used in load calculations - Answers 5000 for a service rated 100-400 amps, the service conductors supplying the entire load associated with a one family dwelling shall be permitted to have an ampacity not less than _ % of the service rating - Answers 83 service entrance and overhead service conductors shall be arranged so that - Answers water shall not enter the service raceway or equipment the radius of the curve of the inner edge of any bend in service entrance cable must be at least _ times the diameter of the cable - Answers five type _ cable can be formed in a gooseneck and taped with a self sealing water resistant thermoplastic - Answers SE entrance cables must be supported within _ of every raceway or enclosure connection - Answers 12 inches although not stipulated in the NEC, some local jurisdictions have adopted _ for service conductors - Answers specific distance requirements underground service conductors are defined as the underground conductors between the service point and the _ to the service entrance conductors in a terminal box, meter, or other enclosure, inside or outside the building wall - Answers first point of connection type USE cable used for service laterals can _ provided 300.5(D) protection requirements are met - Answers emerge above ground at outside terminations overhead service conductors , accessible only to pedestrian traffic, must have a minimum _

Show more Read less
Institution
National Electrical Code
Course
National Electrical Code









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
National Electrical Code
Course
National Electrical Code

Document information

Uploaded on
November 13, 2024
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

National Electrical Code Exam Questions with Verified Solutions (Graded A+)

load calculations must be performed in order to determine the _ - Answers size of services and feeders

a feeder is defined as all circuit conductors between the _ containing fuses or breakers that feed branch
circuits - Answers service disconnecting means and the panelboard

_ are not included in the calculated floor area of a dwelling unit - Answers open porches

a scale ruler is used in _ - Answers determining the location of outlets

the _ is not an important piece of information to gather before performing load calculations - Answers
location of circuit breakers

the _, including the strip heat and blower motor, is necessary information for calculating loads - Answers
total volt-ampere load

the lighting load for residential dwelling unit is _ volt-amperes per square foot - Answers 3

the _ for each floor of a one family dwelling shall be computed using the outside dimensions - Answers
floor area

_must be included when calculating a dwelling unit service - Answers small appliance branch circuits

a dwelling unit must have at least _ small appliance branch circuits - Answers 2

each laundry branch circuit is calculated at - Answers no less than 1500 volt amperes

individual household cooking appliances rated more than _ watts (volt-amperes) can be derated using
Table 220.55 demand factors (and all applicable notes) - Answers 1750

no derating is allowed when there are only 1, 2, or 3 appliances - Answers fastened in place

the term _ designates utilization equipment commonly built in standardized types and sizes and
installed as a unit to perform specific functions - Answers appliance

a clothes dryer neutral load on a feeder can be calculated at _ % - Answers 70

multiplying voltage by amperage produces - Answers volt-amperes (VA)

horsepower ratings must be converted to _ before they can be added to the load calculation form -
Answers volt amperes (VA)

the smaller of the two (or more) _ loads can be omitted as long as they are never energised
simultaneously - Answers noncoincident

fur the purpose of the standard method load calculation for a one family dwelling, the terms neutral and
_ are synonymous - Answers grounded

, a demand factor of _ % can be applied to the nameplate rating load of four or more fastened in place
appliances - Answers 75

in outdoor applications _ grounding electrode conductors must not be installed within 18 inches of the
earth - Answers aluminum

_ are not included in calculating receptacle loads for appliances - Answers air conditioning systems

the exact nameplate rating of the clothes dryer, even if less than _ volt amperes should be used in load
calculations - Answers 5000

for a service rated 100-400 amps, the service conductors supplying the entire load associated with a one
family dwelling shall be permitted to have an ampacity not less than _ % of the service rating - Answers
83

service entrance and overhead service conductors shall be arranged so that - Answers water shall not
enter the service raceway or equipment

the radius of the curve of the inner edge of any bend in service entrance cable must be at least _ times
the diameter of the cable - Answers five

type _ cable can be formed in a gooseneck and taped with a self sealing water resistant thermoplastic -
Answers SE

entrance cables must be supported within _ of every raceway or enclosure connection - Answers 12
inches

although not stipulated in the NEC, some local jurisdictions have adopted _ for service conductors -
Answers specific distance requirements

underground service conductors are defined as the underground conductors between the service point
and the _ to the service entrance conductors in a terminal box, meter, or other enclosure, inside or
outside the building wall - Answers first point of connection

type USE cable used for service laterals can _ provided 300.5(D) protection requirements are met -
Answers emerge above ground at outside terminations

overhead service conductors , accessible only to pedestrian traffic, must have a minimum _ vertical
clearance above finished grade, sidewalks, platforms, or projections that will permit personal contact -
Answers 10ft (3.0meters)

conductors must have a vertical clearance of at least _ above the roof surface - Answers 8ft

voltage between overhead conductors does not exceed _ volts - Answers 300

working space illumination shall not be _ - Answers controlled by automatic means

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
359
Member since
1 year
Number of followers
16
Documents
29332
Last sold
11 hours ago
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.6

55 reviews

5
19
4
14
3
12
2
0
1
10

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions