100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

IBHRE CEPS - Trouble Questions and Correct Answers the Latest Update

Puntuación
-
Vendido
-
Páginas
19
Grado
A+
Subido en
07-11-2024
Escrito en
2024/2025

168. Compared to the the permanent pacemaker, does a temp pacer have constant current or voltage? Also, how much voltage can it generate? 5V or 20V? Constant current, 20V. (Doubles 9.5V) 171. Which patient with acute MI is most likely to need a temp pacer? Inferior MI, Mobitz I AV Bock Inferior MI, bundle branch block Anterior MI, Mobitz I AV Bock Anterior MI, bundle branch block Anterior MI, bundle branch block Acute BBB post MI should be seen as a warning and often proceeds CHB. The RCA commonly supplies blood to the AV node making the impact of an Anterior MI more significant 12. For maximum electrical safety, the ECG monitored patient should be _____________, and the monitor chassis should be _______________ or nonconductive. (Grounded vs Ungrounded) Ungrounded, grounded #Examify | #OnlineExams | #TestPrep | #StudyResources | #AcademicSuccess | #ExamPreparation | #QuizTime | #LearningTools | #Education | #StudentSupport Examify | Smart Grades | Latest update 34. What channel is responsible for the SA and AV node upstroke? Ca++ Slow Channel 38. How does gender effect SVT frequency for AVNRT and AVRT? Women twice as likely to get AVNRT, men twice as likely to get AVRT 39. The plateau (phase 2) occurs on the surface ECG during the_________ , and during mechanical _________________ . QT interval, Systole 48. The pause after atrial pacing is termed: Overdrive suppression 49. Most arrhythmias in the EP lab are caused by? a. Vagal response b. Automaticity c. Triggered d. Reentry Reentry #Examify | #OnlineExams | #TestPrep | #StudyResources | #AcademicSuccess | #ExamPreparation | #QuizTime | #LearningTools | #Education | #StudentSupport Examify | Smart Grades | Latest update 50. What mechanism causes "triggered" arrhythmias? a. Reentry b. After depolarization c. Automaticity of the atrial tissue d. Automaticity of the ventricular tissue After depolarization (think R on T) 51. What do the terms EAD and DAD stand for and what arrythmias are they associated with? EAD - Early after deporization, Torsades DAD - Delayed after depolarization, RVOT VT 55. Which arrhythmia type most closely resembles an "itch of the heart" in acutely ill patients? Automatic arrhythmias 58. 59.. #Examify | #OnlineExams | #TestPrep | #StudyResources | #AcademicSuccess | #ExamPreparation | #QuizTime | #LearningTools | #Education | #StudentSupport Examify | Smart Grades | Latest update 60. 61. 62. 63. An ambulatory patient is

Mostrar más Leer menos
Institución
IBHRE CEPS
Grado
IBHRE CEPS










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
IBHRE CEPS
Grado
IBHRE CEPS

Información del documento

Subido en
7 de noviembre de 2024
Número de páginas
19
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

#Examify | #OnlineExams | #TestPrep | #StudyResources | #AcademicSuccess |
#ExamPreparation | #QuizTime | #LearningTools | #Education | #StudentSupport




IBHRE CEPS - Trouble Questions
and Correct Answers the Latest
Update
168. Compared to the the permanent pacemaker, does a temp pacer have

constant current or voltage? Also, how much voltage can it generate? 5V or

20V?


✓ Constant current, 20V. (Doubles 9.5V)



171. Which patient with acute MI is most likely to need a temp pacer?

Inferior MI, Mobitz I AV Bock

Inferior MI, bundle branch block

Anterior MI, Mobitz I AV Bock

Anterior MI, bundle branch block


✓ Anterior MI, bundle branch block
✓ Acute BBB post MI should be seen as a warning and often proceeds CHB. The RCA
commonly supplies blood to the AV node making the impact of an Anterior MI more
significant



12. For maximum electrical safety, the ECG monitored patient should be

_____________, and the monitor chassis should be _______________ or non-

conductive. (Grounded vs Ungrounded)


✓ Ungrounded, grounded

Examify | Smart Grades | Latest update

,#Examify | #OnlineExams | #TestPrep | #StudyResources | #AcademicSuccess |
#ExamPreparation | #QuizTime | #LearningTools | #Education | #StudentSupport




34. What channel is responsible for the SA and AV node upstroke?


✓ Ca++ Slow Channel



38. How does gender effect SVT frequency for AVNRT and AVRT?


✓ Women twice as likely to get AVNRT, men twice as likely to get AVRT



39. The plateau (phase 2) occurs on the surface ECG during the_________ , and

during mechanical _________________ .


✓ QT interval, Systole



48. The pause after atrial pacing is termed:


✓ Overdrive suppression



49. Most arrhythmias in the EP lab are caused by?

a. Vagal response

b. Automaticity

c. Triggered

d. Reentry


✓ Reentry




Examify | Smart Grades | Latest update

, #Examify | #OnlineExams | #TestPrep | #StudyResources | #AcademicSuccess |
#ExamPreparation | #QuizTime | #LearningTools | #Education | #StudentSupport

50. What mechanism causes "triggered" arrhythmias?

a. Reentry

b. After depolarization

c. Automaticity of the atrial tissue

d. Automaticity of the ventricular tissue


✓ After depolarization (think R on T)



51. What do the terms EAD and DAD stand for and what arrythmias are they

associated with?


✓ EAD - Early after deporization, Torsades
✓ DAD - Delayed after depolarization, RVOT VT



55. Which arrhythmia type most closely resembles an "itch of the heart" in

acutely ill patients?


✓ Automatic arrhythmias



58.






59..






Examify | Smart Grades | Latest update

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Guru01 Chamberlain College Nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
216
Miembro desde
1 año
Número de seguidores
32
Documentos
20783
Última venta
1 semana hace

3.8

36 reseñas

5
15
4
8
3
7
2
1
1
5

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes