a (Centrifugal) correct answers Which of the following compressors are considered a dynamic compressor? a. Centrifugal b. Reciprocating d. Rotary c. Scroll b (Superheated vapor / sub cooled liquid) correct answers What is the condition of the refrigerant as it enters and leaves the condensing coil of a typical light commercial HVAC system? a. Vapor / liquid b. Superheated vapor / sub cooled liquid c. Saturated vapor / saturated liquid d. Hot gas / cool liquid b (Thermal expansion valve) correct answers Which one of the following are considered the best metering device of the industry? a. Capillary tube b. Thermal expansion valve d. Constant pressure expansion valve c. Electronic expansion valve b (POE. Newer refrigerant systems today using R-134a and R-410a use a synthetic Polyester POE oil. Older refrigeration systems using R-12, R-502, and R-22 use a mineral based oil.) correct answers Which of the following types of refrigeration oil would you expect to find in a typical commercial R-134a freezer? a. Mineral 150 b. POE c. AB d. Mineral 300 b (Compressor discharge / compressor suction) correct answers Where does the small single port tube and the larger middle port tube go on a typical residential or light commercial reversing valve? a. Inlet outdoor coil / inlet indoor coil b. Compressor discharge / compressor suction c. Compressor suction / compressor

Show more Read less
Institution
NATE E
Course
NATE E

Content preview

NATE Exam: AC & HP
a (Centrifugal) correct answers Which of the following compressors are
considered a
dynamic
compressor?
a.
Centrifugal
b.
Reciprocating
d.
Rotary
c.
Scroll
b (Superheated vapor / sub cooled liquid) correct answers What is the
condition ofas
refrigerant theit enters and leaves the condensing coil of a typical light
commercial
HVAC
system?
a. Vapor /
liquid
b. Superheated vapor / sub cooled
liquid
c. Saturated vapor / saturated
liquid
d. Hot gas / cool
liquid
b (Thermal expansion valve) correct answers Which one of the
following are
considered the best metering device of the
industry?
a. Capillary
tube
b. Thermal expansion
valve
d. Constant pressure expansion
valve
c. Electronic expansion
valve
b (POE. Newer refrigerant systems today using R-134a and R-410a use a
Polyester POE oil. Older refrigeration systems using R-12, R-502, and R-
synthetic
22 use abased oil.) correct answers Which of the following types of
mineral
refrigeration
would oil to find in a typical commercial R-134a
you expect
freezer?
a. Mineral
150
b. POE
c.
AB
d. Mineral
300
b (Compressor discharge / compressor suction) correct answers Where does
the small
single port tube and the larger middle port tube go on a typical
residential orreversing
commercial light
valve?
a. Inlet outdoor coil / inlet
indoor
b. coil
Compressor discharge / compressor
suction
c. Compressor suction / compressor
discharge

, c. Outlet indoor coil / outlet
outdoor coil
d (restricted liquid line filter/drier) correct answers If you were working on a
3.5 ton split
system, with a 125,000 BTH/H horizontal furnace, and you had a low suction
pressure,
low discharge pressure, high superheat, and high subcooling, what is
wrong with the
system
?
a. low refrigerant
charge
b. overcharged
system
c. overfeeding metering
device
d. restricted liquid line
filter/drier
c (overfeeding metering device) correct answers If you were working on a t
3.5 ton spli
system, with a 125,000 BTU/H horizontal furnace, and you had high suction
pressure,
low discharge pressure, low superheat, and low subcooling, what is
wrong with the
system
?
a. low refrigerant
charge
b. overcharged
system
c. overfeeding metering
device
d. restricted liquid line
filter/drier
a (weak compressor valves) correct answers If you were working on a
3.5 ton split
system, with a 125,000 BTU/H horizontal furnace, and you had high suction
pressure,
low discharge pressure, high superheat, and low subcooling, what is
wrong with the
system
?
a. weak compressor
valves
b. stuck reversing
valve
c. bad indoor check
d. bad outdoor check
valve
valve
b (overcharge system) correct answers If you were working on a 3.5 ton
split system,
with a 125,000 BTU/H horizontal furnace, and you had high suction
pressure, high
discharge pressure, low superheat, and high subcooling, what is
wrong with the
system
?
a. low refrigerant
charge
b. overcharged
system
c. overfeeding metering
device
d. restricted liquid line
filter/drier
d (to compensate charge in the cooling cycle) correct answers You are
working
heat pump
on package
a unit and come across a charge compensator, what is it
used for?
a. to compensate for a low refrigerant
charge

Written for

Institution
NATE E
Course
NATE E

Document information

Uploaded on
November 4, 2024
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
HopeJewels Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
89
Member since
2 year
Number of followers
11
Documents
8867
Last sold
1 week ago
macellen education agencies

CHAMBERLAIN EXAM SHOP YOU WANT AN EXAM - I GOT YOU. Why choose us? ☑️ Committed to your SATISFACTION. ☑️ Competitive pricing ☑️ Guaranteed EXCELLENCE! Feel welcome to contact us. BUY DOUBT FREE!!!!

3.6

8 reviews

5
4
4
0
3
2
2
1
1
1

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions