100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

NHIE Practice QuizCOMPLETE SOLUTIONS GRADED A+

Beoordeling
-
Verkocht
-
Pagina's
15
Cijfer
A+
Geüpload op
01-11-2024
Geschreven in
2024/2025

NHIE Practice QuizCOMPLETE SOLUTIONS GRADED A+

Instelling
MS Or M.S. - Master Of Science
Vak
MS or M.S. - Master of Science









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
MS or M.S. - Master of Science
Vak
MS or M.S. - Master of Science

Documentinformatie

Geüpload op
1 november 2024
Aantal pagina's
15
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

11/2/24, 12:42 AM NHIE Practice Quiz Flashcards | Quizlet



NHIE Practice QuizCOMPLETE SOLUTIONS GRADED A+
Terms in this set (84)


Which is most likely to be considered an Correct Answer: gross negligence.
ethical breach by a home inspector? Feedback: NHIE 2015 p.602 NHIE 2019 Vol.2 p.399
A. gross negligence.
B. negligent misrepresentation.
C. ordinary negligence.
D. fraud.

Electric dryer receptacles in older houses: Correct Answer: require their own circuit
A. work with four-wire cords and plugs. Feedback: Manufacturer Installation Instructions. Newer dryers require a 4 wire cord.
B. may share a wire with a 120-volt 2 hots, a neutral and a ground.
receptacle
C. require their own circuit
D. are rated for at least 50 amps

https://app.prolydian.com/api/media/8f878 Correct Answer: Corrosive atmospheres.
6ac-5eb5-e911-80e0-000d3a141e93 Feedback: Oxidizers like bleach, battery charging stations (lead acid), flue gas from
poorly vented appliances, sewer gas , et al. Will corrode copper piping and wiring
There is evidence of heavy coat of
oxidation on the pictured copper water
pipes. What likely caused this condition
A. High humidity in the basement of the
home has caused the rust.
B. Corrosive atmospheres.
C. Pipe was installed that way. It was
exposed to the weather prior to
installation.
D. There is excessive moisture condensing
on the pipes due to leakage.




https://quizlet.com/543049068/nhie-practice-quiz-flash-cards/ 1/15

, 11/2/24, 12:42 AM NHIE Practice Quiz Flashcards | Quizlet
Sending the inspection report to which Correct Answer: The buyer's agent.
party is LEAST likely to be considered an Feedback: NHIE 2015 p.613, NHIE 2019 Vol. 2 p.411
ethical breach by a home inspector?
Assume all parties attended the inspection.
A. The client's parents.
B. The buyer's agent.
C. The seller's agent.
D. The seller.

Deck ledger boards with floor joists 16' 6", Correct Answer: properly sized lag bolts every 16 inches.
should be securely attached directly to the Feedback: This is critical to prevent pullout during a excessive load on the deck.
house by IRC18 507.9.1.3
A. properly sized lag bolts every 16 inches.
B. 16d galvanized nails placed every 16
inches.
C. properly sized joist hangers for the
house.
D. properly sized lag bolts into the
foundation ledge.

Minimum access size opening for a crawl Correct Answer: 22" x 30"
space where equipment is installed. Feedback: See NHIE Structural Manual page 239
A. 22" x 30"
B. 20" x 32"
C. 24" x 32"
D. 30" x 30"

Wood bearing on a concrete foundation is Correct Answer: 3 inches
required to have a minimum bearing of : Feedback: NHIEM15 124 NHIE19 V2 - 199
A. 1.5 inches
B. 2 inches
C. 2.5 inches
D. 3 inches

When inspecting a home, you note Correct Answer: Wind shear
horizontal cracks in the foundation wall. Feedback: The other three will definitely cause foundation issues under right
Which of the following would NOT be a conditions. Wind shear will affect the structure above grade. NHIEM15 - 115
cause of overload from the outside? NHIE19V2 - 186
A. Wind shear
B. Frost
C. Soil pressure
D. Backfill

What action would most likely reduce Correct Answer: Compressing the insulation behind an electrical cable
fiberglass batt insulation R value of a stud Feedback: Compressing the insulation reduces the open cell volume to hold heat.
cavity by the largest amount? NHIE15 328 NHIE19 V2 p. 285
A. Compressing the insulation behind an
electrical cable
B. Fluffing the insulation
C. A slice in the Kraft facing
D. Not installing a vapor retarder where
required




https://quizlet.com/543049068/nhie-practice-quiz-flash-cards/ 2/15

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
mbitheeunice2015 Teachme2-tutor
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
11
Lid sinds
3 jaar
Aantal volgers
3
Documenten
1870
Laatst verkocht
5 maanden geleden
Classic Writers

I am a certified academic writer specializing in dissertations, online class management, essays, quizzes and exams. Buy my latest updated study materials and improve your grades. 100% sure answers.

4.0

1 beoordelingen

5
0
4
1
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen