NATE Heat Pump Practice Exam with
correct answers
Charging a heat pump with refrigerant is best accomplished in the _______ mode.
A: Heating mode
B: Cooling mode
C: Defrost mode
D: Emergency heating mode - correct answer -B: Cooling mode
Heat pumps can provide both heating in the winter and cooling in the summer. In
which mode is the heat pump more efficient?
A: Heating mode
B: Cooling mode
C: Defrost mode
D: Emergency heating mode - correct answer -A: Heating mode
Which of the following components is exclusive to the heat pump?
A: Condenser
B: Oil separator
,C: Reversing valve
D: Accumulator - correct answer -C: Reversing valve
Which of the following airflow rates is the most reasonable for a heat pump system
operating in the heating cycle?
A: 200 cfm per ton
B: 300 cfm per ton
C: 400 cfm per ton
D: 450 cfm per ton - correct answer -D: 450 cfm per ton
During the heat pump's cooling cycle, the outdoor coil is utilized as a _________ while
the indoor coil is utilized as a____________.
A: Condenser, evaporator
B: Evaporator, condenser
C: Compressor, accumulator
D: Accumulator, condenser - correct answer -A: Condenser, evaporator
Heat is present in winter outdoor air until the outside air ambient temperature
reaches a low temperature of:
A: 0 degrees F
, B: 32 degrees F
C: 273 degrees F
D: -459 degrees F - correct answer -D: -459 degrees F
Technically this is true, but not practical. A heat pump is doing good to continue to
work below 10 deg F.
The heat pump utilizes:
A: Two filter-driers with check valves
B: One bi-flow filter-drier
C: A single mono-flow filter-drier in the liquid line
D: Some use the bi-flow filter-drier and others use two filter-driers with check
valves - correct answer -D: Some use the bi-flow- filter-drier and others use two
filter-driers with check valves
The correct way to size a heat pump is to perform both heating and cooling load
calculations and select the heat pump size by:
A: Adding the heating load and cooling loads
B: Subtracting the smaller load from the larger load
C: Using the heating load to size the system
correct answers
Charging a heat pump with refrigerant is best accomplished in the _______ mode.
A: Heating mode
B: Cooling mode
C: Defrost mode
D: Emergency heating mode - correct answer -B: Cooling mode
Heat pumps can provide both heating in the winter and cooling in the summer. In
which mode is the heat pump more efficient?
A: Heating mode
B: Cooling mode
C: Defrost mode
D: Emergency heating mode - correct answer -A: Heating mode
Which of the following components is exclusive to the heat pump?
A: Condenser
B: Oil separator
,C: Reversing valve
D: Accumulator - correct answer -C: Reversing valve
Which of the following airflow rates is the most reasonable for a heat pump system
operating in the heating cycle?
A: 200 cfm per ton
B: 300 cfm per ton
C: 400 cfm per ton
D: 450 cfm per ton - correct answer -D: 450 cfm per ton
During the heat pump's cooling cycle, the outdoor coil is utilized as a _________ while
the indoor coil is utilized as a____________.
A: Condenser, evaporator
B: Evaporator, condenser
C: Compressor, accumulator
D: Accumulator, condenser - correct answer -A: Condenser, evaporator
Heat is present in winter outdoor air until the outside air ambient temperature
reaches a low temperature of:
A: 0 degrees F
, B: 32 degrees F
C: 273 degrees F
D: -459 degrees F - correct answer -D: -459 degrees F
Technically this is true, but not practical. A heat pump is doing good to continue to
work below 10 deg F.
The heat pump utilizes:
A: Two filter-driers with check valves
B: One bi-flow filter-drier
C: A single mono-flow filter-drier in the liquid line
D: Some use the bi-flow filter-drier and others use two filter-driers with check
valves - correct answer -D: Some use the bi-flow- filter-drier and others use two
filter-driers with check valves
The correct way to size a heat pump is to perform both heating and cooling load
calculations and select the heat pump size by:
A: Adding the heating load and cooling loads
B: Subtracting the smaller load from the larger load
C: Using the heating load to size the system