California Fluoroscopy Test Questions and Answers- 100% pass An image intensifiers photocathode causes ___ to be given off in direct proportion to the intensity of the fluorescent light: a. remnant radiation b. electrons c. x-rays d. light photons - Answer-electrons What fluoroscopic television system device decodes the video signal into a visible image? a. Vidicon camera b. Camera control unit c. Television monitor d. Electron gun - Answer-Television Monitor Which of the following materials are used in the construction of a fluoroscopic tabletop? 1. Lead 2. Aluminum EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 2/107 3. Bakelite 4. Carbon fiber - Answer-2, 3, and 4 Geometric factors in the shape of the image intensification tube b. Focal-film-distance (FFD) c. Object-to-image distance (OID) d. Minification gain - Answer-... If the entrance skin dose is measured from the surface of the tabletop, the x-ray source is located: a. either over or under the table b. under the table c. over the table d. not enough information provided - Answer-b. Under the table The mottle level of an image can be adjusted by: 1. changing mA 2. changing kVp 3. changing the exposure factors 4. increasing the number of available x-ray photons - Answer-All of the above EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 3/107 During a fluoroscopic exam, the main source of scattered radiation is produced from: a. the patient b. x-ray source c. table top d. leakage radiation - Answer-the patient Excessive lighting in the fluoroscopy room: a. Helps to perceive a dim image as brighter b. Helps to properly adjust the overall luminance of the TV image c. Enhances visualization of a black and white TV image d. May result in increasing the technical operating factors - Answer-May result in increasing the technical operating factors Suitable gonad shields must be used: a. Whenever gonads are within the useful x-raybeam b. When shielding of gonads does not interfere with the diagnosis c. On all potentially procreative patients d. At all times - Answer-When shielding of gonads does not interfere with the diagnosis Which of the following are true concerning cine film? EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 4/107 1. Available film sizes are: 70 mm, 100 mm, and 110 mm 2. The larger the film size the better the image quality 3. Nearly all cine-fluorography exams involve studies of the GI system 4. Delivers approximately the same dose as routine photospot image recording - Answer-2 only The exposure rate at the tabletop may not exceed five rads per minute except: 1. when using the ABC on large patients 2. during magnification mode 3. where higher exposure rates are allowed - Answer-b. 1, 2 and 3 only Images produced with photo spot film cameras ___ spot films taken with conventional cassettes. 1. use a higher mA than 2. require about 1/2 to 1/3 the dose of 3. exhibit superior image quality compared to - Answer-require about 1/2 to 1/3 the dose The ability of an imaging system to differentiate small objects that are closely spaced as separate objects is referred to as: a. Differentiation b. Resolution EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 5/107 c. Statistical fluctuation d. Detector contrast - Answer-b. Resolution The photoconductive target in a television camera pick-up tube: a. Conducts electrons across to the target b. Allows a proportional electron charge to be generated at a particular position c. Creates a video signal d. Creates an electronic current which is converted into a video image . - Answer-Allows a proportional electron charge to be generated at a particular position Size distortion is primarily caused by: a. Focal-film-distance (FFD) b. Geometric factors in the shape of the image intensification tube c. Minification gain d. Object-to-image distance (OID) - Answer-Object-to-image distance (OID) The overall luminescence of the TV image may be properly adjusted by: 1. increasing room lighting 2. adjusting the contrast control button on the TV monitor EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 6/107 3. adjusting the brightness control button on the TV monitor - Answer-2 and 3 only Which of the following statements is true concerning fluoroscopic grids? a. Reduces scattered radiation produced in the image intensifier b. The typical grid ratio is 12:1 c. High ratio grids are preferred d. Located between the patient and input layer of the image intensifier - Answer-Located between the patient and input layer of the image intensifier One of the most important actions a fluoroscopist can take to avoid unnecessary radiation exposure to the patient is to use appropriate: a. Illumination b. Primary beam filtration c. Collimation d. Protective lead curtains - Answer-Collimation The increase in effective brightness due to the size reduction

Show more Read less
Institution
Fluoroscopy
Course
Fluoroscopy











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Fluoroscopy
Course
Fluoroscopy

Document information

Uploaded on
October 16, 2024
Number of pages
107
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024




California Fluoroscopy Test Questions
and Answers- 100% pass

An image intensifiers photocathode causes ___ to be given off in direct proportion to the

intensity of the fluorescent light:


a. remnant radiation


b. electrons


c. x-rays


d. light photons - Answer✔✔-electrons


What fluoroscopic television system device decodes the video signal into a visible image?


a. Vidicon camera


b. Camera control unit


c. Television monitor


d. Electron gun - Answer✔✔-Television Monitor


Which of the following materials are used in the construction of a fluoroscopic tabletop?


1. Lead


2. Aluminum

Page 1/107

,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


3. Bakelite


4. Carbon fiber - Answer✔✔-2, 3, and 4


Geometric factors in the shape of the image intensification tube


b. Focal-film-distance (FFD)


c. Object-to-image distance (OID)


d. Minification gain - Answer✔✔-...


If the entrance skin dose is measured from the surface of the tabletop, the x-ray source is

located:


a. either over or under the table


b. under the table


c. over the table


d. not enough information provided - Answer✔✔-b. Under the table


The mottle level of an image can be adjusted by:


1. changing mA


2. changing kVp


3. changing the exposure factors


4. increasing the number of available x-ray photons - Answer✔✔-All of the above



Page 2/107

,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


During a fluoroscopic exam, the main source of scattered radiation is produced from:


a. the patient


b. x-ray source


c. table top


d. leakage radiation - Answer✔✔-the patient


Excessive lighting in the fluoroscopy room:


a. Helps to perceive a dim image as brighter


b. Helps to properly adjust the overall luminance of the TV image


c. Enhances visualization of a black and white TV image


d. May result in increasing the technical operating factors - Answer✔✔-May result in increasing

the technical operating factors


Suitable gonad shields must be used:


a. Whenever gonads are within the useful x-raybeam


b. When shielding of gonads does not interfere with the diagnosis


c. On all potentially procreative patients


d. At all times - Answer✔✔-When shielding of gonads does not interfere with the diagnosis


Which of the following are true concerning cine film?



Page 3/107

, EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


1. Available film sizes are: 70 mm, 100 mm, and 110 mm


2. The larger the film size the better the image quality


3. Nearly all cine-fluorography exams involve studies of the GI system


4. Delivers approximately the same dose as routine photospot image recording - Answer✔✔-2

only


The exposure rate at the tabletop may not exceed five rads per minute except:


1. when using the ABC on large patients


2. during magnification mode


3. where higher exposure rates are allowed - Answer✔✔-b. 1, 2 and 3 only


Images produced with photo spot film cameras ___ spot films taken with conventional

cassettes.


1. use a higher mA than


2. require about 1/2 to 1/3 the dose of


3. exhibit superior image quality compared to - Answer✔✔-require about 1/2 to 1/3 the dose


The ability of an imaging system to differentiate small objects that are closely spaced as

separate objects is referred to as:


a. Differentiation


b. Resolution


Page 4/107

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Emillect West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
28
Member since
1 year
Number of followers
2
Documents
3004
Last sold
1 month ago
GOLDEN ORCHIDS STORE.

On this page, you find all documents, package deals, and flashcards offered by seller Emillect.

3.0

4 reviews

5
1
4
0
3
2
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions