EPA 608 TYPE 3 EXAM QUESTIONS WITH 100% CORRECT ANSWERS On low pressure chillers, moisture typically enters the refrigerant system through *correct answer*air leaks from areas with gaskets or fittings • The maximum test pressure for leak testing a low pressure centrifugal is: *correct answer*10 psig • A hydrostatic tube test kit is used to: *correct answer*determine if a tube leaks • Commercial and industrial process refrigeration systems must be repairedwhen the leak rate exceeds of the charge per year. *correct answer*35% • A rupture disc on a recovery vessel for a low pressure refrigerants relievesat: *correct answer*15 psig • According to ASHRAE Guideline 3-1996, if the pressure in a system risesfrom 1 mm Hg to a level above during a standing vacuum test, the system should be checked for leaks. *correct answer*2.5 mm Hg • The primary water source for a recovery unit condensing coil is. *correct answer*local municipal water supply • When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells before changing with liquid? *correct answer*16.9" Hg vacuum

Montrer plus Lire moins
Établissement
Cours









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Cours

Infos sur le Document

Publié le
15 octobre 2024
Nombre de pages
13
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

HOSMERIT


EPA 608 TYPE 3 EXAM QUESTIONS WITH 100%
CORRECT ANSWERS
• On low pressure chillers, moisture typically enters the refrigerant system
through *correct answer*air leaks from areas with gaskets or fittings
• The maximum test pressure for leak testing a low pressure centrifugal is:
*correct answer*10 psig

• A hydrostatic tube test kit is used to: *correct answer*determine if a tube
leaks
• Commercial and industrial process refrigeration systems must be
repaired when the leak rate exceeds of the charge per year. *correct
answer*35%
• A rupture disc on a recovery vessel for a low pressure refrigerants
relieves at: *correct answer*15 psig
• According to ASHRAE Guideline 3-1996, if the pressure in a system
rises from 1 mm Hg to a level above during a standing vacuum test, the
system should be checked for leaks. *correct answer*2.5 mm Hg
• The primary water source for a recovery unit condensing coil is.
*correct answer*local municipal water supply
• When recharging a refrigeration system with R-11, what vaporpressure
is necessary in the shells before changing with liquid? *correct answer*16.9"
Hg vacuum


• After recovering the liquid refrigerant you must: *correct answer*recover
the vapor refrigerant

, • According to the EPA there is approximately refrigerant vapor left in
an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has
been removed. *correct answer*100 pounds
• Charging refrigerant liquid into a refrigeration system when it is under a
29 inch Hg vacuum can cause the: *correct answer*system water to freeze
• A system does not have to be evacuated all the way to the required level
when: *correct answer*leaks in the appliance make evacuation to the
prescribed level unattainable
• Which of the foloowing repairs would ALWAYS be considered "major"
under EPA's *correct answer*replacement of evaporator coil
• Under EPA's regulation's is used to pressurize a low pressure chiller for
the purpose of opening the system for a non major repair?
*correct answer*warming the refrigerant
• If you are using a recovery machine manufactored AFTER 11-15-93 you
must evacuate an low pressure appliance to before making a major repair.
*correct answer*25 mm of Hg absolute
• After reaching the required recovery vacuum on a chiller, you should
*correct answer*Wait for at least a few minutes to see if the system pressure
rises, indicating that there is till refrigerant in a liquid form or in the oil
• The pressure corresponding to 32 F for R-123 *correct answer*20
inches of HG vacuum
• When evacuating a system the use of too large a vacuum pump can
cause? *correct answer*trapped water to freeze
• Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation
temperature of: *correct answer*35F
$11.49
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Hosmerit Chamberlain College Of Nursing
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
245
Membre depuis
2 année
Nombre de followers
41
Documents
3529
Dernière vente
21 heures de cela
HOSMERIT

Welcome to Hosmerit – Your Trusted Source for High-Quality Study Materials Struggling to find reliable and up-to-date resources to help you ace your exams? Look no further. My store offers a wide range of thoroughly researched and well-organized exam guides, test banks, and past papers for various courses and subjects. ✅ Accurate & Up-to-Date – All materials are regularly reviewed to ensure they reflect the most current curriculum. ✅ High-Scoring Content – Get access to study materials that have helped hundreds of students achieve top grades. ✅ Instant Download – Purchase and access your files immediately — no waiting. ✅ Trusted by Students Worldwide – Join a growing number of students who rely on my resources to stay ahead. Whether you're prepping for midterms, finals, or just want to reinforce your understanding, this store is here to help you succeed with confidence.

Lire la suite Lire moins
4.8

231 revues

5
213
4
9
3
2
2
2
1
5

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions