100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Journeyman Oil Maine Fuel Board Rules

Beoordeling
-
Verkocht
-
Pagina's
34
Cijfer
A
Geüpload op
15-10-2024
Geschreven in
2024/2025

Journeyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesWhat must you do if you notice code violations in a homeowners house? - ANSWER-Notify them and recommend ways to address them What must be done when performing an annual tune-up on a heating system? - ANSWER-A combustion efficiency test and a copy must be posted on site Whenever a furnace, direct fired hot water heater, or boiler is installed the total installation must be brought into compliance with what requirements BEFORE appliance can be fired? - ANSWER-NFPA 31

Meer zien Lees minder
Instelling
Journeyman Oil Maine Fuel Board Rules
Vak
Journeyman Oil Maine Fuel Board Rules











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Journeyman Oil Maine Fuel Board Rules
Vak
Journeyman Oil Maine Fuel Board Rules

Documentinformatie

Geüpload op
15 oktober 2024
Aantal pagina's
34
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Journeyman Oil Maine Fuel Board

Rules


What must you do if you notice code violations in a homeowners house? -

ANSWER-Notify them and recommend ways to address them




What must be done when performing an annual tune-up on a heating

system? - ANSWER-A combustion efficiency test and a copy must be posted

on site




Whenever a furnace, direct fired hot water heater, or boiler is installed the

total installation must be brought into compliance with what requirements

BEFORE appliance can be fired? - ANSWER-NFPA 31




When an emergency arises that does not allow adequate time to get a

chimney lined/and or repaired before installing the new heating appliance

the licensee may defer the required repairs for how long? - ANSWER-90 days

,What must be performed before a new installation? - ANSWER-A heat loss

system design and load calculation. A copy must be retained to be presented

upon request of board inspector




What may be installed in the supply line but not a return line? - ANSWER-A

check valve




If the low water cut off is not installed directly in the boiler where may it be

installed? - ANSWER-Main supply line (vertical riser) as close to boiler as

possible, or in a water column of continuous piping attached directly to the

boiler




A listed lever or wheel thermally operated oil shut off valve must be installed

where? - ANSWER-At the burner and the oil supply tank




When outside tanks are used a thermally operated shut off valve must be

installed where? - ANSWER-The supply line enters the inside of the building

and where the oil line enters the room where the appliance is located

,When inside tanks are used and the oil supply tank is installed in a separate

room, a thermally shutoff valve must be installed where? - ANSWER-Where

the line enters the room where the appliance is located




All copper oil supply and return lines must be encased in a continuous piece

of no metallic liquid tight conduit such as PVC, ENT, coated copper tubing.

The end of the conduit shall not exceed how far from any connection except

the connection at fuel tank? - ANSWER-2 inches




All oil fired BOILERS must be provided with a properly installed and operating

what? - ANSWER-Low Water cut off




Where shall a low water cutoff be installed? - ANSWER-At the level

recommended by the manufacture, but in no case below the crown sheet




Whenever the oil supply is taken from the top of an oil tank a thermally

operated wheel or lever type shut-off valve must be installed where? -

ANSWER-At the tank and at the burner

, In order to avoid undetected oil leaks under floors, the conduit must be how

much bigger than the supply and return lines? - ANSWER-One pipe size

larger




An oil supply line that penetrates a foundation wall must be what? -

ANSWER-Sealed




What must coated copper tubing have installed at the tank when used

underground? - ANSWER-Oils Safety Valve or PRV




When an oil filter or other accessory equipment is connected to a copper

piping smaller than 3/4 "and is not directly connected to the oil tank or

burner the filter or other device must be what? - ANSWER-Rigidly supported

by wall or floor mounted brackets




What must supply and return lines be connected with? - ANSWER-Flare

fittings




What fittings shall not be used unless for introduction of lines at top of the

tank with a single or double tap bushing? - ANSWER-Compression fittings

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
NursingTutor1 West Virginia University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1619
Lid sinds
2 jaar
Aantal volgers
1073
Documenten
18045
Laatst verkocht
2 dagen geleden
Nursing Tutor

Paper Due? Worry not. Hello. Welcome to NursingTutor. Here you\'ll find verified study materials for your assignments, exams and general school work. All papers here are graded A to help you get the best grade. Also, I am a friendly person so, do not hesitate to send a message in case you have a query. I wish you Luck.

3.9

442 beoordelingen

5
210
4
76
3
87
2
21
1
48

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.