Device RAC Exam Questions and Answers
(Latest Update 2025)
Which division has primary jurisdiction over a vascular graft with an
antibiotic based on primary mode of action?



A. CDER

B. CBER

C. CDRH

D. OCP - Correct Answer ✅ C. CDRH



In this combination of a device and a drug, the primary mode of action is that
of the vascular graft (device). The antibiotic is supportive in this case.



A company wants to modify its legally marketed device such that the
modification does not affect the intended use or alter the fundamental
scientific technology of the device. If the design outputs of the modified
device meet the design input requirements, this change would be best filed
as a(n):



A. Special 510(k)

B. Abbreviated 510(k)

C. Traditional 510(k)

D. De novo 510(k) - Correct Answer ✅ A. Special 510(k)



A Special 510(k) is allowed if a modification to the legally marketed device is
being made that relies on compliance with design controls, including design
validation. The incentive provided for manufacturers to choose this option is
that ODE intends to process special 510(k)s within 30 days of receipt. See
the CDRH guidance published in 1998 entitled The New 510(k) Paradigm -
Alternate Approaches to Demonstrating Substantial Equivalence in Premarket
Notifications.

,Device RAC Exam Questions and Answers
(Latest Update 2025)
Under the statutory violations, failure to meet 510(k) requirements for a
device that is required to have a 510(k) and is in commercial distribution is
considered to be:



A. Adulteration.

B. Improper use

C. Misbranded

D. Fraudulent - Correct Answer ✅ C. Misbranded



A marketed device that needs a 510(k) for commercialization but failed to
comply with the requirements is considered to be Misbranded. See the FD&C
Act, 502(o).



A company's competitor is marketing a Class II suture which dissolves during
the third week of use. The company's current product has to be removed by
a physician. However, a change in weaving configuration gives this product
the same dissolving time as the competitor's. When can the company's new
suture be marketed?



A. This requires a new 510(k) since significant change in product instructions
might affect efficacy.

B. After submission in a periodic report

C. After reporting clinical studies in an annual report

D. After submission of labeling change - Correct Answer ✅ A. This requires
a new 510(k) since significant change in product instructions might affect
efficacy.



A new intended use requires a 510(k) clearance.

,Device RAC Exam Questions and Answers
(Latest Update 2025)
A physician reports to a manufacturer that a patient was hospitalized with
acute sepsis after treatment with an approved device. This side effect is not
listed in the package insert. This event must be reported by the
manufacturer to FDA no later than:



A. 5 calendar days

B. 15 calendar days

C. 30 calendar days

D. The next quarterly or annual report - Correct Answer ✅ C. 30 calendar
days



Serious injury must be reported within 30 days even if it is expected and
stated in the IFU



A handling and storage system for medical devices must always include:



A. Procedures for rotation of stock

B. Separate rooms or cages for release and quarantine products

C. Procedures for product receipt and transfer

D. Environmentally controlled areas for products with shelf life - Correct
Answer ✅ C. Procedures for product receipt and transfer



Procedures for receipt and transfer of products are required; see 21 CFR
820.150(b).



You have modified your 510(k) cleared device with a special 510(k). In which
of the following cases would you need to create a new listing for the device?



A. You have added new sizes and shapes in the product portfolio.

, Device RAC Exam Questions and Answers
(Latest Update 2025)
B. You have changed the material composition of the device.

C. You have changed the package of the device.

D. None of the above. - Correct Answer ✅ D. None of the above.



According to 21 CFR 807.22(b), a separate form FDA-2892 shall be submitted
for each device or device class listed with the FDA. Devices having variations
in physical characteristics such as size, package, shape, color or composition
should be considered to be one device: Provided, The variation does not
change the function or intended use of the device.



Per the QSR, when an investigation of a complaint is conducted, all of the
following are requirements for inclusion in investigation record EXCEPT:



A. The dates and results of the investigation

B. The nature and details of the complaint

C. Changes in procedures correcting quality problems

D. Any reply to the complainant - Correct Answer ✅ C. Changes in
procedures correcting quality problems



The requirement is for corrective and preventative action and only needed if
corrective action was taken per investigation. See Sec. 820.198. Complaint
files.



The QSR calls for finished device mfgers to carry out all of the following
EXCEPT:



A. Quality audits conducted by individuals who don't have direct
responsibility for operation being audited

B. Annual audits of operations

C. Document the dates and results of quality audits and re-audits

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Allivia Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
717
Member since
2 year
Number of followers
398
Documents
12734
Last sold
1 day ago
Allivia

Hi there! My name is Allivia, and I'm a passionate and experienced online tutor. I offer support to help students succeed. you can access study materials, notes, and guides to help you excel academically I am hear to help you. review so as to know the quality of service offered & to better improve your expirience. thank you and welcome back. BONUS! BONUS! BONUS! For every student you refer to me with an order that is completed and paid transparently, I will give you one free study document you need or do one assignment for you, free of charge! Thank you Very much for the purchase Kindly leave a Review to help know the Quality of Document and those who have reviewed thanks again

Read more Read less
4.0

135 reviews

5
71
4
20
3
26
2
7
1
11

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions