Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 1 out of 2 pages
Summary

Summary of Lesson 9 'LC-MS'

Document preview thumbnail
Preview 1 out of 2 pages

This document includes the info from the slides plus my lesson notes from lesson 5 of concepts, given by Xaveer van Ostade. I also have Kurt Boonen's lessons (Lessons 2,3,4 and 8), but the notes are on the slides. If you are also interested in this, you can always contact me via messenger:))

Content preview

Lecture 9: 12/12
LC-MS
- HPLC: beat smaller diameter -> pu5 larger pressure on the column so that the solvent
goes through the column
- Separa=on of complex mixtures of proteins and pep=des, immediately followed by
mass spectrometric analysis of the separated components.
- Online connec=on of chromatography to the ESI source: eluted and separated pep=des
are directly sent into the mass spectrometer where the MW (MS scan) and the AA
sequence (MS/MS scan) are determined.
- 1 duty cycle is the =me the MS needs to perform 1 MS scan and several MS/MS scans
of the highest peaks (see below)
- You can direct elute the elusion in the ESI source
o You don’t lose sample
- If we have complex mixtures of pep=des and proteins -> you elute several pep=des
simultaneously from the column -> MS cannot follow
- Eluted pep=des are directly introduced in the MS -> MS scan and MS-MS scan
- Since an MS/MS scan demands some =me and chromatography runs con=nuously, a
selec=on must be made of the ions (precursors) that have to undergo an MS/MS scan:
o In prac=ce the mass spec runs 1 MS scan (± 1 sec.) allowing to determine the
pep=de masses within a certain =me slot, followed by an MS/MS scan on three
to eight selected (usually most intense) pep=de (total ± 5 sec.). Total = 1 duty
cycle.
§ Now: ms
§ More sensi=ve
§ You will pick up more pep=des for one protein-> reliability of the
iden=fica=on increases dras=cally
o If sample is very complex: several pep=des reside within one chromatographic
peak and cannot always be detected and sequenced by the mass spectrometer
(peak satura=on).
§ To reduce the peak satura=on, we can tell the MS that if it sees a pep=de
with a m/z value of 837,5 don’t select it because it comes for example
of kera=n
-> Therefore, exclusion lists, containing pep=des that can be neglected (no
MS/MS scan), can be entered into the mass spectrometer.
- Usually: reverse phase chromatography at micro or capillary scale. If chromatographic
flow (5-1000 µl/min) is too high for the mass spec (=ll 500 nl/min.) a ‘spli5er’ (part to
waster and part to ESI source) is used
o Nanoscale is for the analy=cal scale
- Nanopumps with a reproducible linear speed =ll ± 50 nl/min. are also available.
o Nano scale has several advantages:
§ Lower flow rates (see above) are similar to these from ESI source, hence no
spli5er needed and less sample and solvent go to the waste.
§ Nano column can be used as ionisa=on source
§ Increased sensi=vity since the volume solvent per =me unit is reduced,
allowing the sample to concentrate.

Document information

Study
Uploaded on
September 7, 2024
Number of pages
2
Written in
2023/2024
Type
Summary
$7.91

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
5
Followers
0
Items
65
Last sold
8 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions