NCC PRACTICE TEST 6 QUESTIONS AND ANSWERS
Wire bundles are commonly secured using _____. - Answers -tie wraps

The NEC requires that all grounding electrodes be _____. - Answers -bonded

If it is necessary to oversize a motor to provide a wide speed range, it should not be
increased by more than _____. - Answers -1hp

When installing hammer-driven pins and studs in soft concrete block, the drive pin or
stud should be embedded in the concrete for at least _____. - Answers -1 1/4" (32 mm)

The maximum allowable spacing between horizontal wireway supports is _____. -
Answers -10'

If a mercury thermostat seems out of adjustment, the first thing to do is ____. - Answers
-check for accurate leveling

A type of anchor that is a good choice when jacking and leveling the fastening
component is a _____. - Answers -stud bolt anchor

Which of the following types of cable is suitable for dry locations only? - Answers -Type
NM


When troubleshooting a motor, the possible cause for constant chatter is _____. -
Answers -a broken pole shader

A type of conduit that has a wall thickness less than that of RMC but thicker than EMT is
_____, - Answers -IMC

One characteristic of aluminum conduit is that it ____. - Answers -is more resistant to
wet environments

When used in control cable, which of the following must be grounded in order to be
effective? - Answers -Drain wires

The requirements for grounding and bonding electric services can be found in _____. -
Answers -NEC Article 250

To position cable so that it is not under tension, it is necessary to _____. - Answers -
train conductors

When making a conduit-to-box connection and a bonding cire will be installed, use a
_____ - Answers -grounding locknut

, Select the list of conductors that begin with the smallest wire and go up. - Answers -18
AWG, 14 AWG, 1/0, 3/0

Automatic changeover thermostats have a minimum interlock setting, also known as the
____. - Answers -deadband

To determine the correct connector size for MC cable, ______ - Answers -refer to the
manufacturer's literature

To properly install heat-shrink insulators, _____. - Answers -Slip the insulator over the
connector and apply heat for a few seconds

When the refrigeration compressors are driven by conventional , nonhermetic, motors,
the motors and controls are subject to the requirements in _____. - Answers -NEC
Article 430

When installing conduit in reinforced concrete, it is best to use a ____. - Answers -
concrete box with ears

Conduit is best stored _____. - Answers -in pipe racks.

In a typical DC electric braking circuit, power is supplied to the braking relay by a -
Answers -NOTO contact

For the AFD operating frequency range shown in the figure above, the range of output
frequencies over which the AFD output voltage remains constant while the frequency
varies is identified in the figure as - Answers -the straight horizontal line, B to C

For the AFD operating frequency range shown in the figure above, the range of AFD
output frequencies over which the ratio of volts to hertz remains constant is identified in
the figure above as - Answers -the diagonal, dashed line, A to B

Equipment consisting of busbars mounted inside an enclosure that provides a means of
tapping the service-entrance conductors is called a - Answers -busway

Connecting a 120V heating cable to a 240V circuit will - Answers -melt the cable

The conductor or busbar with a higher voltage to ground in a delta-connected four-wire
system is also known as the - Answers -high leg

A device that uses dissimilar metals to control electron flow is known as a - Answers -
thermocouple

When installing multi-family services, the service disconnect - Answers -may be placed
indoors under specific circumstances

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GEEKA YALA UNIVERSITY
View profile
Follow You need to be logged in order to follow users or courses
Sold
2011
Member since
3 year
Number of followers
1447
Documents
48509
Last sold
14 hours ago

3.8

345 reviews

5
172
4
61
3
44
2
16
1
52

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions