Fire Pump Test Questions and Answers Heat exchangers shall be checked for _____ water flow. - Answer️️ - cooling All alarm pilot lights should be in what state? - Answer️️ -Off There are two requirements listed under pump house conditions, choose both listed below. - Answer️️ -Ventilating louvers are free to operate & Heat is adequate, not less than 40F for diesel pump rooms. Weekly inspection requires verification that pump suction discharge and bypass valves should be fully open? - Answer️️ -True When verifying the electrical system conditions, the controller pilot light should be? - Answer️️ -Green Diesel engine fuel tank level, float switch and solenoid valve operation shall be checked _____. - Answer️️ -weekly What fire pump type do you record the time to crank? - Answer️️ -Diesel The pertinent visual observation categories required to be inspected weekly checklist are? - Answer️️ -Pump house conditions, Pump system conditions, electrical system conditions, diesel engine system conditions, steam system conditions. The purpose of inspecting the pump assembly? - Answer️️ -Appears to be in operating condition and is free from physical damage ©SOPHIABENNETT@ Saturday, August 24, 2024 8:52 AM 2 The transfer switch normal pilot light should be illuminated. - Answer️️ - True The isolating switch for electric pumps should be closed. - Answer️️ -True Pump packing boxes, bearings and casing shall be checked for _____. - Answer️️ -overheating The reverse phase alarm pilot light for electric pumps should be off. - Answer️️ -True The purpose of testing the pump assembly is to ensure automatic and manual operation upon demand and continuous delivery of the required system output. An additional purpose is to detect _____. - Answer️️ - deficiencies not evident by inspection The normal phase rotation pilot light should be on. - Answer️️ -True At what level should the oil level in the vertical motor sight glass be? - Answer️️ -Normal When verifying water level in suction reservoir during weekly inspection, the water level should be full. - Answer️️ -True Controllers include air, _____, or electrical operated units. - Answer️️ - hydraulic At what level should the fuel tank be? - Answer️️ -2/3 ©SOPHIABENNETT@ Saturday, August 24, 2024 8:52 AM 3 The weekly test pertinent adjustments shall be made while the pump is _____. - Answer️️ -running The controller selector switch should be in the _____ position. - Answer️️ -auto The number of engine operating hours is measured by the _____? - Answer️️ -engine running time meter The oil level in the right angle gear drive should be normal. - Answer️️ - True Types of centrifugal fire pumps include single and multistage units of horizontal and vertical shaft design. - Answer️️ -True For both Electric & Diesel pumps, the wet pit suction

Show more Read less
Institution
Fire Pump
Course
Fire Pump









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Fire Pump
Course
Fire Pump

Document information

Uploaded on
August 29, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

©SOPHIABENNETT@2024-2025 Saturday, August 24, 2024 8:52 AM



Fire Pump Test Questions and Answers

Heat exchangers shall be checked for _____ water flow. - Answer✔️✔️-
cooling

All alarm pilot lights should be in what state? - Answer✔️✔️-Off

There are two requirements listed under pump house conditions, choose
both listed below. - Answer✔️✔️-Ventilating louvers are free to operate &
Heat is adequate, not less than 40F for diesel pump rooms.

Weekly inspection requires verification that pump suction discharge and
bypass valves should be fully open? - Answer✔️✔️-True

When verifying the electrical system conditions, the controller pilot light
should be? - Answer✔️✔️-Green

Diesel engine fuel tank level, float switch and solenoid valve operation
shall be checked _____. - Answer✔️✔️-weekly

What fire pump type do you record the time to crank? - Answer✔️✔️-Diesel

The pertinent visual observation categories required to be inspected
weekly checklist are? - Answer✔️✔️-Pump house conditions, Pump system
conditions, electrical system conditions, diesel engine system conditions,
steam system conditions.

The purpose of inspecting the pump assembly? - Answer✔️✔️-Appears to be
in operating condition and is free from physical damage


1

, ©SOPHIABENNETT@2024-2025 Saturday, August 24, 2024 8:52 AM


The transfer switch normal pilot light should be illuminated. - Answer✔️✔️-
True

The isolating switch for electric pumps should be closed. - Answer✔️✔️-True

Pump packing boxes, bearings and casing shall be checked for _____. -
Answer✔️✔️-overheating

The reverse phase alarm pilot light for electric pumps should be off. -
Answer✔️✔️-True

The purpose of testing the pump assembly is to ensure automatic and
manual operation upon demand and continuous delivery of the required
system output. An additional purpose is to detect _____. - Answer✔️✔️-
deficiencies not evident by inspection

The normal phase rotation pilot light should be on. - Answer✔️✔️-True

At what level should the oil level in the vertical motor sight glass be? -
Answer✔️✔️-Normal

When verifying water level in suction reservoir during weekly inspection,
the water level should be full. - Answer✔️✔️-True

Controllers include air, _____, or electrical operated units. - Answer✔️✔️-
hydraulic

At what level should the fuel tank be? - Answer✔️✔️-2/3




2

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SophiaBennett Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
130
Member since
1 year
Number of followers
5
Documents
8567
Last sold
2 weeks ago
EXAM GAME-CHANGER

Exam Questions and Answers Section : Study Like a Pro, Study Smart, Study with Sophia.

3.7

26 reviews

5
10
4
5
3
7
2
1
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions