Power Engineering 5th class book 2 Questions and Verified Answers External heat gains include those by: - ANS Infiltration, Ventilation and Solar radiation A wind velocity of _______________ is used to calculate the winter infiltration heat loses - ANS 24 km/h ( 15mph ) The heat given off by light fixtures is not greatly affected by the: - ANS Room temperature Heat loses through large, single pane window sections are ________________ double pane windows, which have the space between the panes filled with argon - ANS significantly greater than The amount of heat lost by conduction, convection, radiation, and infiltration is directly affected by the - ANS wind velocity Radiators are constructed in such a manner as to present a ______________________ to radiate heat from the steam or hot water contained in the radiator - ANS large surface area Packless radiator valves have a __________________ diaphragm that completely seals off the valve body to prevent steam from leaking out around the valve steam - ANS bronze The exhauster consists of a series of ________________ through which water is forced by the vacuum pump - ANS nozzles

Meer zien Lees minder
Instelling
Power Engineering
Vak
Power Engineering









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Power Engineering
Vak
Power Engineering

Documentinformatie

Geüpload op
28 augustus 2024
Aantal pagina's
12
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Power Engineering 5th class book 2
Questions and Verified Answers
External heat gains include those by: - ANS Infiltration, Ventilation and Solar radiation

A wind velocity of _______________ is used to calculate the winter infiltration heat
loses - ANS 24 km/h ( 15mph )




A
The heat given off by light fixtures is not greatly affected by the: - ANS Room
temperature




VI
Heat loses through large, single pane window sections are ________________ double
pane windows, which have the space between the panes filled with argon - ANS




TU
significantly greater than

The amount of heat lost by conduction, convection, radiation, and infiltration is directly
affected by the - ANS wind velocity
IS
Radiators are constructed in such a manner as to present a ______________________
to radiate heat from the steam or hot water contained in the radiator - ANS large
OM

surface area

Packless radiator valves have a __________________ diaphragm that completely seals
off the valve body to prevent steam from leaking out around the valve steam - ANS
bronze
NA


The exhauster consists of a series of ________________ through which water is forced
by the vacuum pump - ANS nozzles
JP




The air vent consists of a small housing containing a sealed cylinder partially filled with
_______________________ - ANS volatile liquid

In a gravity return system, the boiler should be placed - ANS well below the lowest
radiator

A pressure balancing device that prevents the boiler pressure from forcing the water in
the boiler into the return line is called a - ANS Hartford loop

, If the water level falls too low during operation of a steam heating boiler, the operator
should - ANS shut the boiler down

Steam in a two-pipe, vacuum return system is supplied at a maximum pressure of
_______________________ - ANS 103 kPa ( 15psi)

Cause of insufficient steam supply to the heating units can be attributed to - ANS
Improper pitch, Defective radiator valve, Clogging of connections and valve

Special diverter fitting are required in ________________ to ensure an adequate flow of




A
water each convector - ANS One-pipe hot water systems




VI
With the pump running in a hot water heating system, the normal differential pressure
between the suction and discharge is _______________ - ANS 55 kPa ( 8psi)




TU
Which of the following should be included in the routine operation of a hot water heating
system - ANS Testing the controls and safety relief valve on a regular basis, keeping
the boiler room and boiler clean and tidy, refer periodically to the boiler manufacturer's
operation instructions
IS
If there is an air lock after repairs have been made on the piping system, the operator
should - ANS open the system vent valves, or check operation of the automatic air
OM

venting system

Which is the following are advantages of a warm air heating system - ANS A more
uniform temperature distribution can be obtained due to a positive air circulation, filters
may be used to clean the air, controlled amounts of external ventilation may be drawn
NA


into the system

What is the name given to the furnace type that has the return air enter the top and the
supply air leave the bottom of the system - ANS Downflow furnace
JP




The flue gas temperature on the heat exchanger exit of a warm air furnace is about
_______________ - ANS 230°C (450°C)

The air blower used in a forced warm-air furnace is usually driven by - ANS An electric
motor via a V-belt connected to a fixed pulley mounted on the blower shaft

Which of the following are types of air distribution systems - ANS Extended plenum,
Perimeter loop, Perimeter radial

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
JPNAOMISTUVIA Arizona Western College
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
124
Lid sinds
3 jaar
Aantal volgers
55
Documenten
1258
Laatst verkocht
1 week geleden
Unlock Your Potential with Our Comprehensive Study Guides Based on RESEARCH AND VERIFIED WORK!

Are you ready to elevate your learning experience FOR GRADE A+ RESULTS ? Our expertly crafted study guides are designed to empower students of all levels. Whether you're preparing for exams or mastering a new subject, Choose from digital downloads, bundled packages to suit your study style. Good Luck As You Study!

4.4

36 beoordelingen

5
24
4
6
3
4
2
0
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen