INDUSTRIAL FOAM PUMPERS ARE BUILT ACCORDING TO ? - NFPA 11 C AND 1901 ( TEST ANSWER IS BOTH 11 C AND 1901) LARGEST CAPACITY pumper DURING RELAY SHOULD BE? - The source pumper WHAT IS NOT PART OF THE DAILY APPARATUS INSPECTION? - EXERCISING THE VOLUME SERIES CONTROL LEVER One gallon of water weighs? - 8.35 LBS How many cubic inches in a gallon of water - 231 cubic inches How much does a cubic foot of water weigh? - 62.5 LBS How many gallons of water in a cubic foot? - 7.481 gallons How many inches in a cubic foot? - 1728 Cubic Inches How much pressure does a column of water one foot high exert at it's base - .434 Psi HOW MANY INCHES OF MERCURY IS EQUAL TO 13.55 INCHES OF WATER? - ONE ONE PSI OF PRESSURE WILL RAISE A COLUMN OF WHATER HOW MANY FEET? - 2.304 ft WHAT IS THE SYMBOL FOR MERCURY - HG WHAT IS RELIABLE LIFT - 14.7 FEET ( THE HEIGHT OF A COLUMN OF WATER THAT MAY BE LIFTED IN SUFFICIENT QUANTITY TO PROVIDE A RELIABLE FIRE FLOW) THEORETICAL LIFT IS - 33.87 FtWhat should pumpers flow at? - 100% CAPACITY @ 150 PSI, 70% @ 200 PSI, AND 50 % @ 250 PSI Pumper capacity at draft are set at? - WITH 10 FT OF LIFT THROUGH 20 FT OF HARD SUCTION RELAY PUMPER EVOLUTIONS SHOULD BE SHUT DOWN AT - The on scene pumper first ELEVATING WATER DEVICES TYPICALLY RANGE IN HEIGHT ? - From 50-75 Ft WHAT IS NFPA 1901 - STANDARD FOR AUTOMOTIVE FIRE APPARATUS EQUIPMENT FAILURES CAN BE PREVENTED BY PERFORMING? - ROUTINE MAINTINANCE CHECKS ON A REGULAR BASIS APPARATUS WITH WATER TANKS OF 1000 GAL. OR LESS - MUST HAVE A TANK FILL LINE OF AT LEAST 1 INCH APPARATUS WITH TANKS OF MORE THAN 1000 GAL. - MUST HAVE 2 INCH TANK FILL LINE WHAT DOES PTO DRIVE LIMIT PUMP CAPACITY TO? - 500 GPM MINIMUM PUMP CAPACITY FOR PUMP DESIGN IS - 750 GPM A rear pump is _________ for driver? - Less safe WHERE SHOULD APPARATUS PROTECTING STRUCTURES DURING WILD LAND FIRES BE PARKED ? - Off the roadways NEW APPARATUS MUST BE ABLE TO COME TO A COMPLETE STOP FROM A SPEED OF - 20 mph in a distance of 35ftThe first element in learning to drive safely? - Safety conscious attitude Atmospheric pressures decreases? - .5psi per 1000ft of elevation

Show more Read less
Institution
Fire Service Pump Operator State
Course
Fire Service Pump Operator State

Content preview

Fire Service Pump Operator State test
INDUSTRIAL FOAM PUMPERS ARE BUILT ACCORDING TO ? - NFPA 11 C AND 1901 ( TEST ANSWER
IS BOTH 11 C AND 1901)



LARGEST CAPACITY pumper DURING RELAY SHOULD BE? - The source pumper

WHAT IS NOT PART OF THE DAILY APPARATUS INSPECTION? - EXERCISING THE VOLUME SERIES
CONTROL LEVER

One gallon of water weighs? - 8.35 LBS



How many cubic inches in a gallon of water - 231 cubic inches

How much does a cubic foot of water weigh? - 62.5 LBS



How many gallons of water in a cubic foot? - 7.481 gallons



How many inches in a cubic foot? - 1728 Cubic Inches



How much pressure does a column of water one foot high exert at it's base - .434 Psi



HOW MANY INCHES OF MERCURY IS EQUAL TO 13.55 INCHES OF WATER? - ONE



ONE PSI OF PRESSURE WILL RAISE A COLUMN OF WHATER HOW MANY FEET? - 2.304 ft



WHAT IS THE SYMBOL FOR MERCURY - HG



WHAT IS RELIABLE LIFT - 14.7 FEET ( THE HEIGHT OF A COLUMN OF WATER THAT MAY BE LIFTED
IN SUFFICIENT QUANTITY TO PROVIDE A RELIABLE FIRE FLOW)



THEORETICAL LIFT IS - 33.87 Ft

, What should pumpers flow at? - 100% CAPACITY @ 150 PSI, 70% @ 200 PSI, AND 50 % @ 250 PSI



Pumper capacity at draft are set at? - WITH 10 FT OF LIFT THROUGH 20 FT OF HARD SUCTION



RELAY PUMPER EVOLUTIONS SHOULD BE SHUT DOWN AT - The on scene pumper first



ELEVATING WATER DEVICES TYPICALLY RANGE IN HEIGHT ? - From 50-75 Ft



WHAT IS NFPA 1901 - STANDARD FOR AUTOMOTIVE FIRE APPARATUS



EQUIPMENT FAILURES CAN BE PREVENTED BY PERFORMING? - ROUTINE MAINTINANCE CHECKS
ON A REGULAR BASIS

APPARATUS WITH WATER TANKS OF 1000 GAL. OR LESS - MUST HAVE A TANK FILL LINE OF AT
LEAST 1 INCH



APPARATUS WITH TANKS OF MORE THAN 1000 GAL. - MUST HAVE 2 INCH TANK FILL LINE



WHAT DOES PTO DRIVE LIMIT PUMP CAPACITY TO? - 500 GPM



MINIMUM PUMP CAPACITY FOR PUMP DESIGN IS - 750 GPM



A rear pump is _________ for driver? - Less safe



WHERE SHOULD APPARATUS PROTECTING STRUCTURES DURING WILD LAND FIRES BE PARKED ? -
Off the roadways



NEW APPARATUS MUST BE ABLE TO COME TO A COMPLETE STOP FROM A SPEED OF - 20 mph in a
distance of 35ft

Written for

Institution
Fire Service Pump Operator State
Course
Fire Service Pump Operator State

Document information

Uploaded on
August 18, 2024
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ACADEMICMATERIALS City University New York
View profile
Follow You need to be logged in order to follow users or courses
Sold
600
Member since
2 year
Number of followers
185
Documents
10571
Last sold
6 hours ago

4.0

98 reviews

5
53
4
13
3
21
2
3
1
8

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions