100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Journeyman electrician exam prep With complete solution | Latest 2024/25 Rated A+

Beoordeling
-
Verkocht
-
Pagina's
7
Cijfer
A+
Geüpload op
15-08-2024
Geschreven in
2024/2025

Journeyman electrician exam prep With complete solution | Latest 2024/25 Rated A+

Instelling
Journeyman Electrician
Vak
Journeyman electrician









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Journeyman electrician
Vak
Journeyman electrician

Documentinformatie

Geüpload op
15 augustus 2024
Aantal pagina's
7
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Journeyman electrician exam prep With
complete solution | Latest 2024/25 Rated
A+
What table sizes bonding jumpers for for AC systems? - 250.102(C)(1)

The NEC defines continuous load to be a load where max current on the circuit
continues for at least how many hours? - Three

To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than
how many current carrying conductors in a raceway? - Greater than three

Where in the NEC codebook would you find EMT sizes for a given size and number of
conductors? - Annex C, Table C.1

Section 210.20(A) states that the over current protection for branch circuits including
continuous loads must be greater than 100% of the noncontinuous plus ____ of the
continuous load. - 125%

Liquidtight Flexible Metal Conduit shall be fastened within of each box or other conduit
termination - Twelve inches

314.28(A)(1) states that straight pulls in pull boxes with conductors size 4 AWG or
larger, box length should be greater than or equal to times the trade diameter of the
largest conduit entering box. - Eight

Chapter 9 note 4 states conduit nipples less than 24 inches can fill to a max of their
cross sectional area - 60 percent

Table 348.22 gives the max number of insulated conductors in size _______ FMC? -
3/8 (trade size)

Guest rooms of hotels, motels, & sleeping rooms in dorms need a MIN or _____
general purpose receptacles installed that are readily accessible? - Two

When branch-circuit conductors are contained inside a ballast compartment and they
are within 3 inches of the ballast, the conductors shall have a temperature rating of at
LEAST _____.

a) 105 degrees C
b) 90 degrees C
c) 75 degrees C
d) 60 degrees C - B: 90 degrees C

, Ref: 410.68

Class _____ locations are those that are hazardous because of the presence of easily
ignitible fibers or materials producing combustible flyings.

a) I
b) II
c) III
d) IV - C: III
Ref: 500.5(D)

Class _____ locations are those in which flammable gases, flammable liquid produced
vapors, or combustible liquid produced vapors are present that are explodable. - Class
1

Class ____ locations are those that are hazardous because of combustible dust -
Class II

Conductors with _______ Insulation have a greater ampacity when used in a dry
location compared to when used in a wet location - THHW

When calculating total load for buildings and finding minimum branch circuit load, what
must be factored into the volt amps for an exterior electric sign? - Demand load (1.25)

Table C.11 and C.11(A) show conductor numbers for size for schedule 40 PVC, what is
the difference in charts? - Compact vs stranded conductors

332.30 states that type MI cable shall be supported at intervals of at least how many
feet? - Six feet

What table sizes equipment grounding conductors for specific over current devices? -
250.122

Wye is another term for what kind of systems? - Three phase

What is the equation for voltage drop? - VD=2KID/CM

In the voltage drop equation, what is the value CM, and where is it found in the NEC
codebook? - Circular mile, chapter 9, table 8

Conductors installed under at least _______ inches of concrete are considered by NEC
Section 230.6 to be outside the building. - 2 inches

Conductors installed in electrically heated floors in bathrooms, kitchens, and in hydro
massage bathtub locations shall be provided with what kind of protection? - GFCI
424.44(E)

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
STUVEX NURSING
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
729
Lid sinds
2 jaar
Aantal volgers
313
Documenten
15137
Laatst verkocht
1 dag geleden
STUVATE - STUVIA USA

Our store is a comprehensive destination for buying and selling a variety of documents. we offer a vast range of documents that cater to different needs and requirements, our documents are well-researched, accurate, and of high quality, ensuring customer satisfaction. whether you are looking for legal documents, academic papers, business reports or miscellaneous documents we`ve got you covered.

3.8

112 beoordelingen

5
43
4
29
3
23
2
7
1
10

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen