,Charging a heat pump with refrigerant is best accomplished in the _______ mode.
A: Heating mode
B: Cooling mode
C: Defrost mode
D: Emergency heating mode - Answer: B: Cooling mode
Heat pumps can provide both heating in the winter and cooling in the summer. In which mode is the
heat pump more efficient?
A: Heating mode
B: Cooling mode
C: Defrost mode
D: Emergency heating mode - Answer: A: Heating mode
Which of the following components is exclusive to the heat pump?
A: Condenser
B: Oil separator
C: Reversing valve
, D: Accumulator - Answer: C: Reversing valve
Which of the following airflow rates is the most reasonable for a heat pump system operating in the
heating cycle?
A: 200 cfm per ton
B: 300 cfm per ton
C: 400 cfm per ton
D: 450 cfm per ton - Answer: D: 450 cfm per ton
During the heat pump's cooling cycle, the outdoor coil is utilized as a _________ while the indoor coil is
utilized as a____________.
A: Condenser, evaporator
B: Evaporator, condenser
C: Compressor, accumulator
D: Accumulator, condenser - Answer: A: Condenser, evaporator
Heat is present in winter outdoor air until the outside air ambient temperature reaches a low
temperature of:
A: 0 degrees F
B: 32 degrees F