while conducting a pump capacity test, if the net pump discharge pressure is correct but the nozzle flow is too high, the - the discharge gate must be closed further When using hose lines above ground, the usual pressure calculation is to add _____ psi for each story of the building below the fire floor. - 5 You should switch from pressure to volume mode when - more than half of the rated capacity of the pump will be required To calculate friction loss in 2 1/2" fire hose when the flow is near 100 gpm, which of the following formulas should be used? - FL=cq(2)L The pressure remaining once water has begun flowing is known as _____ pressure. - residual When the flow through a hose line increases from 100 gpm to 400 gpm, the friction loss increases _____ times. - 16 the recommended pressure for a standard fog nozzle is - 100 PSI The foam application technique that directs the foam stream on the ground near the front edge of a burning liquid pool or spill is the: - roll on method Master stream nozzles are: - Either solid of fog streams _________ consist of small return (bypass) water line connected from the discharge side of the pump back to the intake side of the pump - around the pump proportioners which type of nozzle is very effective when fighting a fire in a basement or cellar - distributors nozzleif the inlet pressure to the eductor is too high - foam may not be inducted when lowering a barrel strainer into the water, it should have _____ inches of water in all directions - 24 an increase in vacuum while drafting may indicate - a clogged strainer hose that is laid from the fire to the hydrant is considered a - reverse lay a straight stream is considered a - pattern of an adjustable fog nozzle pump discharge pressure is equal to - Nozzle pressure + friction loss as flow increases, pressure will ___________ provided pump seal remains constant - increase the primary function of the fire department pumper is to - provide water at an adequate pressure for fire streams Once the power take off has been properly activated and the pump is engaged, the vehicle speedometer should show a speed of: - slightly above 0 mph The speedometer on an apparatus is primarily used to show speed but may also indicate - the pump is turning the maximum height water can be drafted is approximately __________ feet, as opposed to the theoretical lift of 33.8 feet - 25 feet when using foam to extinguish a fire, the separating method - creates a barrier between the fuel and the fireare controlled by monitoring the water flow and controlling the speed of a positive displacement foam concentrate pump - variable flow, variable rate direct injection systems The amount of work that pump must do to produce a fire stream is called ______ pressure. - pump discharge which foam has a surfactant added that makes it more fluid - flueroprotein the purpose of the ________ is to provide circulating feed from several mains - grid system When relay pumping, if the intake pressure drops below 20 psi: - there is a danger of cativation in-line relay valves allow for - Late-arriving pumper to hook up without interrupting operations. the flow from a 1 inch nozzle tip with a nozzle pressure of 50 PSI approximately _______ gpm - 210 the process that causes foam concentrate to move through an in-line foam eductor and into the water stream is called the ________ effect - venturi

Show more Read less
Institution
FAE
Course
FAE









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
FAE
Course
FAE

Document information

Uploaded on
August 11, 2024
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

FAE
while conducting a pump capacity test, if the net pump discharge pressure is correct but the nozzle flow
is too high, the - the discharge gate must be closed further



When using hose lines above ground, the usual pressure calculation is to add _____ psi for each story of
the building below the fire floor. - 5



You should switch from pressure to volume mode when - more than half of the rated capacity of
the pump will be required



To calculate friction loss in 2 1/2" fire hose when the flow is near 100 gpm, which of the following
formulas should be used? - FL=cq(2)L



The pressure remaining once water has begun flowing is known as _____ pressure. - residual



When the flow through a hose line increases from 100 gpm to 400 gpm, the friction loss increases _____
times. - 16



the recommended pressure for a standard fog nozzle is - 100 PSI



The foam application technique that directs the foam stream on the ground near the front edge of a
burning liquid pool or spill is the: - roll on method



Master stream nozzles are: - Either solid of fog streams



_________ consist of small return (bypass) water line connected from the discharge side of the pump
back to the intake side of the pump - around the pump proportioners



which type of nozzle is very effective when fighting a fire in a basement or cellar - distributors
nozzle

, if the inlet pressure to the eductor is too high - foam may not be inducted



when lowering a barrel strainer into the water, it should have _____ inches of water in all directions -
24



an increase in vacuum while drafting may indicate - a clogged strainer



hose that is laid from the fire to the hydrant is considered a - reverse lay



a straight stream is considered a - pattern of an adjustable fog nozzle



pump discharge pressure is equal to - Nozzle pressure + friction loss



as flow increases, pressure will ___________ provided pump seal remains constant - increase



the primary function of the fire department pumper is to - provide water at an adequate pressure
for fire streams



Once the power take off has been properly activated and the pump is engaged, the vehicle speedometer
should show a speed of: - slightly above 0 mph

The speedometer on an apparatus is primarily used to show speed but may also indicate - the
pump is turning



the maximum height water can be drafted is approximately __________ feet, as opposed to the
theoretical lift of 33.8 feet - 25 feet

when using foam to extinguish a fire, the separating method - creates a barrier between the fuel
and the fire

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainarium Delaware State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1826
Member since
2 year
Number of followers
1043
Documents
22338
Last sold
1 day ago

3.8

317 reviews

5
147
4
60
3
54
2
16
1
40

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions