Complete Solutions 100% Verified
Specifications are particularly directed to Correct answer-Manufacturers of devices
Newly manufactured scales are required to be designated as Correct answer-Class I, II, III,
IIIL, or IIII
The normal valance position of the weighbeam of a beam scale shall be Correct answer-
horizontal
A county sealer/ director of W&M may, with the approval of the Secretary of Food and
Agriculture, use a frequency of inspection which is Correct answer-Different from
regulations
On a prescription scale equipped with a balance indicator, if this indicator consists of an
indicator and a graduated scale and they are not in the same plane, the clearance between the
indicator and the graduations shall not be more than Correct answer-0.04 inches
Graduations of a scale beam shall be so varied in length that Correct answer-they may be
conveniently read
A poise stop is not necessary on a steelyard when Correct answer-there is no zero
graduation
, CDFA Weight Verification Practice Questions with
Complete Solutions 100% Verified
The adjusting material in a poise shall be securely enclosed and firmly fixed in position and it
shall not be in contact with the weigh beam, if softer than Correct answer-brass
The sensitivity requirement of a scale shall be applied in conjunction with Correct
answer-regardless of maintenance and acceptance tolerances
A variable frequency inspection plan shall provide for testing of all commercial devices on
Correct answer-regular frequency, variable frequency and statistical sampling procedure
Each weighing device shall have a minimum of one permanent and conspicuous identification
marking with what information Correct answer-Name, initials or trademark of the
manufacturer or distributor, model number, and non repetitive serial number
The graduated interval is Correct answer-distance from the center of one graduation to
the center of the next graduation in a graduated series
non retroactive means Correct answer-Only enforceable with respect to devices made
after implimentation
Meat beams, steelyards, portable platform, and belt conveyor scales all have a frequency of
inspection which is Correct answer-identical
An axle load scale is normally Correct answer-permanently installed
, CDFA Weight Verification Practice Questions with
Complete Solutions 100% Verified
what term does not apply to nose iron Correct answer-range
The term nominal when used in reference to a scale, measure, weight, etc. means
Correct answer-intended or stated value
A tare mechanism is used primarily for the purpose of Correct answer-balancing out the
weight of empty containers
the director may issue rules and regulations for Correct answer-device repairmen,
accuracy of commercial devices, and responsibilities of device repairmen
To perform a shift test on a dairy product test scale the necessary test weight load is
Correct answer-18 grams
A weighing device found correct by a repairman authorized pursuant to law may Correct
answer-be used commercially pending re-inspection by a sealer
Correct means any weight, weighing, or counting instrument which Correct answer-
Meets all tolerance and specification requirements established by regulations of the director
A scale with an indicator and graduations is an example of Correct answer-analog