R410a Certification Exam With Questions and Verified Answers Recovery cylinders used with R410 must have a DOT rating of: - ANSWER * DOT 4BA 400 * DOT 4BW 400 A system using R410 refrigerant has bubbles in the sight glass. Technicia n A says that the system must be low on refrigerant. Technician B says that the bubb les could be caused by the blended refrigerant flashing in the increased volume of th e sightless. Who is right? - ANSWER Technician B only When charging an R410a system that uses a thermostatic expansion valve, proper charge can be determined by measuring: - ANSWER Subcooling When charging an R410a system that uses a capillary tube or a fixed metering device, proper charge can be determined by measuring: - ANSWER Superheat Compressor internal pressure relief settings for R410a systems are: - ANSWER 550 psig to 625 psig When handling refrigerants technicians should: - ANSWER Wear approve d eye protection and gloves R410a systems use a high pressure switch that will open at approximately: - ANSWER 610 psig plus or minus 10 psig Subcooled liquid in the receiver may _____ subcooling, deoending on surrounding conditions. - ANSWER Lose or gain When installing a liquid line filter drier on a R410a system, be certain that it has a pressure rating of at least: - ANSWER 600 psig The flow area of a R410a metering device is: - ANSWER Smaller than that of a r22 metering device Which of the following statements is true of R407C? - ANSWER It may separate (fractionate) into its component refrigerants A true azeotropic blend: - ANSWER * Will not fractionate * Has no temperature glide * Behaves as a single component refrigerant When a blend is zeotropic, or near-azeotropic (NARM): - ANSWER * Leaks may cause a change in composition of the blend * It will have a temperature glide * It can fractionate R410a is also known as: - ANSWER * Suva 410A * AZ- 20 * Puron The temperature glide for R410a is less than _____ degrees Farenheit over air conditioning and refrigerating operating ranges: - ANSWER 0.3 Polyol Ester (POE) - ANSWER Can be irritating to the skin, is hygroscopic, has improved heat transfer characteristics over mineral oils The low pressure control on R410a systems will open at: - ANSWER 50 psig Compressor ratio is calculated as: - ANSWER Absolute discharge pressu re divided by absolute suction pressure Both suction and discharge pressures of R410a systems are _____ than R22 systems. - ANSWER 40% to 70% higher Because of its higher vapor heat capacity, the discharge temperature of R410a is _____ than R22. - ANSWER Lower
Exam (elaborations)
R410a Certification Exam With Questions and Verified Answers
R410a Certification Exam With Questions and Verified Answers...
Institution
R410a Certification
Course
R410a Certification
Whoops! We can’t load your doc right now. Try again or contact support.
Written for
- Institution
- R410a Certification
- Course
- R410a Certification
Document information
- Uploaded on
- July 26, 2024
- Number of pages
- 6
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Unknown
Subjects
- r410a
- r 410a
- r410
- r410a
- r410a certification
- r410a certification exam
-
r410a certification exam with questions
-
recovery cylinders used with r410
-
a system using r410 refrigerant has bubbles
Content preview
$12.49
Get access to the full document:
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
Also available in package deal
Package deal
R410A BUNDLED EXAMS WITH QUESTIONS AND ANSWERS
11
2024
$ 115.49
More info