100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

RPSGT EXAM MOCK QUESTIONS WITH COMPLETE SOLUTIONS GRADED A+

Beoordeling
-
Verkocht
-
Pagina's
32
Cijfer
A+
Geüpload op
17-06-2024
Geschreven in
2023/2024

_________defined as conjunction with initial deflection >500msec - Answer-Slow rolling eye movements _____is the most powerful zeitgeber and regulates the circadian system. - Answer-light ____measured from trough to trough - Answer-duration A bipolar derivation utilizes which of the following? a. One electrode that overlies an electrically active area b. Two electrodes that overlie an electrically active area c. One electrode over an active and one over an inactive area d. Two electrodes that overlie an electrically inactive area - Answer-b. Two electrodes that overlie an electrically active area why? Analog systems allowed the technologist to select a string of bipolar derivations comprised of exploring electrodes that overlie electrically active recording sites for both input 1 and input 2 using a mechanical electrode selector panel. This could also be accomplished using a bipolar jack box on which designated connections listed for input 1 and input 2 of each channel routed signals directly to the respective amplifier. Today, the selector panel has been replaced by a digital system with software control of electrode switching. A bipolar derivation utilizes which of the following? - Answer-. Two electrodes that overlie an electrically active area a lower LFF setting results in - Answer-A longer time constant results in _____: A pattern of cardiac variability often seen in patients with OSA is: A. Persistent Tachycardia B.Persistent bradycardia C. Tachycardia alternating with bradycardia D. Prolonged QT interval - Answer-Tachycardia alternating with bradycardia A simple way for a sleep technologist to estimate heart rate is to count the number of QRS complexes in a 30-second epoch and: A. Write down the number as the heart rate B. Divide by 30 C. Multiply by 2 D. Determine the interval in millimeters - Answer-Multiply by 2 A small undesired electrical voltage passing through the human body is known as - Answer-mirco shock Accessory equipment such as a CPAP machine or radio placed near the headbox may cause: A. A 60-Hz artifact B. Electrode pops C. Spurious electrode impedance measures D. Gap junctions with sparking - Answer-A 60-Hz artifactAccording to the AASM Scoring Manual, a pause in the heart rate of 3 seconds or longer is called: A. Asystole B. Bradycardia C. Prolonged QT interval D. Premature ventricular contraction - Answer-Asystole According to the American Academy of Sleep Medicine (AASM) Scoring Manual, a sustained (30 seconds or longer) heart rate of 90 beats per minute or higher during sleep is called: A. Atrial fibrillation B. Left bundle branch block C. Bradycardia D. Tachycardia - Answer-Tachycardia ACh release in the cortex is highest in stage: - Answer-rem ach-producing cells generate which of the following before the onset of REM sleep - Answer-pgo waves Actigraphy is the: A. Measurement and quantification of REM movements B.Recording and analysis of the nondominant wrist movements C. Recording of leg movements D. Home sleep testing - Answer-Recording and analysis of the nondominant wrist movements actigraphy worn____days - Answer-3 Adaptive servo ventilation is an effective treatment for which of the following disorders? A. Obesity hypoventilation syndrome B. Nocturnal asthma C. Hunter-Cheyne-Stokes breathing pattern D. Congenital central hypoventilation syndrome - Answer-hunter-cheyne-stokes breathing pattern add Apneas and hypopneas then multiply by 60 then divide by tst - Answer-AHI adults enter _________ cycles - Answer-3-5 cycles All of the following may be helpful in identifying 60-Hz artifact EXCEPT: a. applying and removing the AC (line) filter. b. decreasing time base to count the frequency. c. decreasing the HFF from 70 Hz to 35 Hz. d. increasing the LFF from 0.3 Hz to 1.0 Hz. - Answer-increasing the LFF from 0.3 hz to 1.0 hz

Meer zien Lees minder
Instelling
RPSGT
Vak
RPSGT











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
RPSGT
Vak
RPSGT

Documentinformatie

Geüpload op
17 juni 2024
Aantal pagina's
32
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ACADEMICMATERIALS City University New York
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
564
Lid sinds
2 jaar
Aantal volgers
186
Documenten
10590
Laatst verkocht
4 dagen geleden

4.1

95 beoordelingen

5
53
4
11
3
21
2
3
1
7

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen