100% Zufriedenheitsgarantie Sofort verfügbar nach Zahlung Sowohl online als auch als PDF Du bist an nichts gebunden 4.2 TrustPilot
logo-home
Prüfung

HVAC Excellence Questions with 100% correct answers _ verified

Bewertung
-
Verkauft
-
seiten
9
Klasse
A+
Hochgeladen auf
16-06-2024
geschrieben in
2023/2024

HVAC Excellence Questions with 100% correct answers _ verified

Hochschule
Kurs









Ups! Dein Dokument kann gerade nicht geladen werden. Versuch es erneut oder kontaktiere den Support.

Schule, Studium & Fach

Hochschule
Studium
Kurs

Dokument Information

Hochgeladen auf
16. juni 2024
Anzahl der Seiten
9
geschrieben in
2023/2024
Typ
Prüfung
Enthält
Fragen & Antworten

Themen

Inhaltsvorschau

HVAC Excellence

- ✅✅-An inert gas
10lbs. Of refrigerant passing through a water cooled condenser will lose 20
BTU of heat per lb. if 10lbs. Of water passes through the condenser with an

✅✅
entering temperature of 80'F. The temperature of the water leaving the
condenser is. - -100'F

A compound pressure gauge measures - ✅✅-Pressure and vacuum
✅✅
A compressor that has broken reed valve will cause these symptoms. -
-High suction pressure and low discharge pressure

A customer complains that their air conditioning system is running constantly,

✅✅
but not cooling enough. The suction line is very cold and the compressor is
sweating. The most likely cause is. - -low refrigerant charge.

A customer reports that the residential split system had a compressor
replaced last week by another service company now the unit is not cooling
properly when you arrive and inspect the unit you find that the evaporator
seems to be starved of refrigerant. On examining the condensing unit you find

✅✅
that the liquid line is sweating where it leaves the drier this is most likely the
result of. - -Debris from the burned out compressor has clogged the drier


✅✅
A decrease in superheat causes the thermostatic expansion valve begins to. -
-Close


✅✅
A dirty evaporator in an air conditioning system will cause these symptoms -
-Low suction pressure and low discharge pressure

A drain trap should be installed on a split system when the - ✅✅-Air handler
drain is on the negative side


✅✅
A faulty condenser fan motor on an air conditioning system will cause these
symptoms - -High suction pressure and high discharge pressure

, A liquid line filter drier should be placed between the. - ✅✅-Condenser and
metering device

✅✅-Store liquid refrigerant
A liquid receiver is used to. -

A liquid-to-suction heat exchanger is often used to - ✅✅-Increase liquid
subcooling


✅✅
A low pressure cut-off switch is used to. (and is also called loss of charge
switch.) - -Establish a minimum operating pressure in the evaporator.


✅✅
A low refrigerant charge in a air conditioning system will cause these
symptoms - -Low suction pressure and low discharge pressure

A mechanical shaft seal is necessary on a - ✅✅-Open drive compressor /
external force

A partially clogged capillary tube metering device can cause - ✅✅-A starved
evaporator

A partially iced over evaporator can be caused by. - ✅✅-An undercharge
A refrigerant gives up heat when it. - ✅✅-It condenses
✅✅
A refrigerant overcharge in a capillary Tube air conditioning system will cause
the symptoms - -High suction pressure and high discharge pressure


✅✅
A rise in evaporator pressure causes the automatic expansion valve to begin
to. - -Close

A scroll compressor moves refrigerant by means of. - ✅✅-Involute spirals
A sight glass would normally be located. - ✅✅-In the liquid line, before the
metering device.

A technician has found an air conditioning system with a leak in the liquid line
after the line is repaired the system evacuated and properly recharged when

✅✅
the system is started the compressor is noisy and running hot the most
probable cause of the noise is - -Low oil in the system
$9.93
Vollständigen Zugriff auf das Dokument erhalten:

100% Zufriedenheitsgarantie
Sofort verfügbar nach Zahlung
Sowohl online als auch als PDF
Du bist an nichts gebunden

Lerne den Verkäufer kennen
Seller avatar
stuviaexam

Lerne den Verkäufer kennen

Seller avatar
stuviaexam Cambridge University
Folgen Sie müssen sich einloggen, um Studenten oder Kursen zu folgen.
Verkauft
3
Mitglied seit
1 Jahren
Anzahl der Follower
1
Dokumente
747
Zuletzt verkauft
10 Jahren vor

0.0

0 rezensionen

5
0
4
0
3
0
2
0
1
0

Kürzlich von dir angesehen.

Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Häufig gestellte Fragen