Dell EMC PowerEdge Corrective Maintenance 2024 Questions and Answers 100% Pass
Dell EMC PowerEdge Corrective Maintenance 2024 Questions and Answers 100% Pass A mini-PERC RAID Controller requires replacement. What are the steps taken to ensure the RAID controller is installed properly? - Correct Answer ️️ -Angle the mini-PERC card so that one end of the card engages with the cardholder on the system board. Next, ensure the guide pins are aligned to the cable and the mini-PERC. Lastly, secure the two screws, being careful to not overtighten Following the PowerEdge naming convention, which generation does the M830 server belong to? - Correct Answer ️️ -13G When installing two NVMe drives in a DSS8440 system, two slots are dedicated for NVMe drive installation. Which slots are they? Click the correct highlighted section, then Submit. - Correct Answer ️️ -8,9 While on a call to service a PowerEdge server, the reported issue is intermittent. The ability to stream real-time events and data logs is instrumental in diagnosing the problem. To successfully stream real-time metrics, the customer must have the correct iDRAC license installed. Which one of the iDRAC licenses enables this feature? - Correct Answer ️️ -Express There was an unexpected system shutdown due to a sudden power outage on a customer system. The data could be expected to be retained by which of the following type of memory? - Correct Answer ️️ -NVDIMM What is the minimum space required on a USB Key to create a Support Live Image (SLI)? - Correct Answer ️️ -4GB Which of the following is not an ability of the ePSA? - Correct Answer ️️ -To run the Easy Restore after the system board replacement. To add a Host Bus Adapter (HBA) to the system board, which server component could be used? - Correct Answer ️️ -Peripheral Riser Card The image shows the front view of the PowerEdge MX7000. Identify the compute sleds in the system. Click the correct highlighted section, then Submit. - Correct Answer ️️ - [Check online for photo] The PSU LED of a DSS 7000 flashes green five times then turns off. What could this indicate? - Correct Answer ️️ -PSU mismatch. During the installation of a processor, select the caution tips to follow. Select two options that apply. - Correct Answer ️️ -Ensure the protective cover is present and rightly secured. Do not touch the processor- sensitive contacts during installation. A collection of Server Event Logs (SEL) must be extracted and sent to the Technical Support team for troubleshooting using the Dell SupportAssist Collection utility. In the iDRAC GUI below, which tab contains the Dell SupportAssist feature? Click the correct highlighted section, then Submit. - Correct Answer ️️ -Maintenance What is the correct sequence of steps to run the ePSA through the Dell EMC Lifecycle Controller? - Correct Answer ️️ -<F10> -> Hardware Diagnostics -> Run H
Written for
- Institution
- Dell Client Foundations
- Course
- Dell Client Foundations
Document information
- Uploaded on
- June 3, 2024
- Number of pages
- 6
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
dell emc poweredge corrective maintenance 2024 que
Also available in package deal