100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

API 653 Recertification Quiz with 100% Correct

Beoordeling
-
Verkocht
-
Pagina's
5
Cijfer
A+
Geüpload op
31-05-2024
Geschreven in
2023/2024

API 653 Recertification Quiz with 100% Correct Per API 653 , with of the following is required when converting an existing tank to operation at elevated temperatures when it was not originally designed and constructed to API 650, Appendix M? - Correct Answer ️️ -The Shell to bottom joint shall be evaluated for fatigue When removing an existing tank bottom, all arc-gouged areas of the tank shell-to- bottom shall be: - Correct Answer ️️ -examined using magnetic particle inspection, and defective areas repaired and re-examined. If RBI assessment has been conducted and the tank has cathodic protection plus a thin- film lining, the maximum inspection interval is: - Correct Answer ️️ -14 years When installing a new nozzle in a tank of unknow material, what stress value should be used to calculate the required shell thickness and reinforcement? - Correct Answer ️️ - 20,000 lbf/in2 In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a wet environment. - Correct Answer ️️ -may double with every 18 °F increase in temperature above 77 °F. Grade 350W/50W is acceptable for tank plate to a maximum thickness of: - Correct Answer ️️ -45mm (1.75in) if fully killed and made to a fine grain practice. If an RBI assessment has been conducted and the tank has a release prevention barrier, the maximum initial inspection interval is: - Correct Answer ️️ -25 years As an alternative to the procedures in API 653 for the evaluation of any thinning of the tank shell below minimum required wall thickness may be evaluated for continued service using which code? - Correct Answer ️️ -API RP 579, section 4, 5 or 6. When welding on a tank shell constructed of Group I steel that is greater than 1.5 inches thick below what minimum metal temperature ?preheat? - Correct Answer ️️ - 200°F When evaluated an existing temperature services tank, which has a successful service history of operation but was not originally designed and constructed to the requi

Meer zien Lees minder
Instelling
Api 653
Vak
Api 653









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Api 653
Vak
Api 653

Documentinformatie

Geüpload op
31 mei 2024
Aantal pagina's
5
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

API 653 Recertification Quiz with 100% Correct Per API 653 , with of the following is required when converting an existing tank to operation at elevated temperatures when it was not originally designed and constructed to API 650, Appendix M? - Correct Answer ✔️✔️-The Shell to bottom joint shall be evaluated for fatigue When removing an existing tank bottom, all arc -gouged areas of the tank shell -to-
bottom shall be: - Correct Answer ✔️✔️-examined using magnetic particle inspection, and defective areas repaired and re -examined. If RBI assessment has been conducted and the tank has cathodic protection plus a thin -
film lining, the maximum inspection interval is: - Correct Answer ✔️✔️-14 years When installing a new nozzle in a tank of unknow material, what stress value should be used to calculate the required shell thickness and reinforcement? - Correct Answer ✔️✔️-
20,000 lbf/in2 In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a wet environment. - Correct Answer ✔️✔️-may double with every 18 °F increase in temperature above 77 °F. Grade 350W/50W is acceptable for tank plate to a maximum thickness of: - Correct Answer ✔️✔️-45mm ( 1.75in) if fully killed and made to a fine grain practice. If an RBI assessment has been conducted and the tank has a release prevention barrier, the ma ximum initial inspection interval is: - Correct Answer ✔️✔️-25 years As an alternative to the procedures in API 653 for the evaluation of any thinning of the tank shell below minimum required wall thickness may be evaluated for continued service using whic h code? - Correct Answer ✔️✔️-API RP 579, section 4, 5 or 6. When welding on a tank shell constructed of Group I steel that is greater than 1.5 inches thick below what minimum metal temperature ?preheat? - Correct Answer ✔️✔️-
200°F When evaluated an existi ng temperature services tank, which has a successful service history of operation but was not originally designed and constructed to the requirement of API 650, appendix M, which condition temperature has to be used? - Correct Answer ✔️✔️-The max Operating Temperature shall not exceed the temperature at which the tank has successfully operated in the pass. Flange material used for tank repair and alteration shall meet the minimum requirements for the material specifications according to: - Correct Answer ✔️✔️-The as built standard which is an advantage of thick film UN -REINFORCED linings ? - Correct Answer ✔️✔️-
Fast curing and can be put back in service after 24 hours at normal ambient temperature. The perimeter welds on a welded -on patch plate in the critic al zone should be ? - Correct Answer ✔️✔️-Two-pass and examined visually and by either MP or PT. Existent welds on a tank shell are found to e closer than allowed by API 650 (7th Edition). Under what conditions can these welds be considered to be acceptabl e for

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
BrittieDonald Howard Community College
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
399
Lid sinds
2 jaar
Aantal volgers
162
Documenten
20443
Laatst verkocht
11 uur geleden
BrittieDonald Study Solutions.

Get Help in Your Due Online and Actual Exams, Assignments with Well Researched and Up-to date Study Materials for Guaranteed Success

3.5

89 beoordelingen

5
41
4
13
3
7
2
5
1
23

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen