OCI Foundation Course Study Guide Questions with 100% Correct Answers | Updated 2024 | Guaranteed A+
OCI Foundation Course Study Guide Questions with 100% Correct Answers | Updated 2024 | Guaranteed A+ Which statement about OCI is NOT true? - An availability domain is one or more data centers located within a region. - A single fault domain can be associated with multiple availability domains within a region. - Availability domains do not share infrastructure, such as power, cooling, or network, within a region. - An OCI region is a localized geographic area. - A single fault domain can be associated with multiple availability domains within a region. A fault domain is a subdivision of an availability domain. Each availability domain contains three fault domains. Fault domains let you distribute your instances so that they are not on the same physical hardware within a single availability domain. A fault domain cannot be associated with multiple availability domains. Which Oracle Cloud Infrastructure service is NOT intended for a multicloud solution? - Oracle Roving Edge Infrastructure - Oracle Interconnect for Azure - Oracle MySQL Heatwave on AWS - Oracle Database Service for Azure - Oracle Roving Edge Infrastructure Oracle Roving Edge Infrastructure is a service that provides a portable, ruggedized device running a subset of OCI services, designed for deployment in the field outside of a traditional data center. It is not a service specifically designed for multicloud deployment. On the other hand, services like Oracle Database Service for Azure and Oracle Interconnect for Azure are designed to allow Oracle Cloud Infrastructure to interoperate with Azure, indicating a multicloud approach. Oracle MySQL HeatWave is an analytics service for MySQL Database service that runs on AWS but the account management and billing and metering are done through OCI. Which capability can be used to protect against failures within an OCI availability domain? - Load Balancer - Compartments - Regions - Fault Domain - Fault Domain Fault domains provide a capability to protect your applications and instances from unexpected hardware failures or network outages within an availability domain. They provide anti-affinity: Each fault domain runs on its own set of physical hardware, so a failure that impacts one fault domain does not affect instances in other fault domains.
Document information
- Uploaded on
- May 29, 2024
- Number of pages
- 26
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers