A system is supplied from the factory with charge of 5 pounds 10 ounces for a 15 foot line set. The line set is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigeration to be added for each added foot of refrigerant line set length. What is the total refrigerant charge for the system? A. 6 ounces B. 5 pounds C. 5 pounds 10 ounces D. 6 pounds - D. 6 pounds 15ft - 25ft = 10ft x .6 = 6 ounces 5 pounds + 10 ounces + 6 ounces 5 pounds + 16 ounces = 6 pounds The purpose of using flux when soldering is to: A. anneal the surface. B. give better heat flow. C. reduce oxidation. D. pre-seal the oxidation. - C. reduce oxidation. Outdoor condensing units that are installed in areas where flooding is possible must: A. be mounted above flood level. B. utilize NEMA 1 enclosures. C. be mounted under an overhanging eave. D. use water resistant components. - A. be mounted above flood level.The component used to reduce sound transmission and prevent water leaks on a rooftop air conditioner packaged unit installation is the: A. curb gasket. B. silicone caulk. C. roof flashing. D. roofing tar. - A. curb gasket.

Show more Read less
Institution
NATE AC Service Certification
Course
NATE AC Service Certification










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NATE AC Service Certification
Course
NATE AC Service Certification

Document information

Uploaded on
May 28, 2024
Number of pages
27
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NATE AC Service Certification A system is supplied from the factory with charge of 5 pounds 10 ounces for a 15 foot line set. The line set is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigeration to be added for each added foot of refrigerant line set length. What is the total refrigerant charge for the system? A. 6 ounces B. 5 pounds C. 5 pounds 10 ounces D. 6 pounds - D. 6 pounds 15ft - 25ft = 10ft x .6 = 6 ounces 5 pounds + 10 ounces + 6 ounces 5 pounds + 16 ounces = 6 pounds The purpose of using flux when soldering is to: A. anneal the surface. B. give better heat flow. C. reduce oxidation. D. pre -seal the oxidation. - C. reduce oxidation. Outdoor condensing units that are installed in areas where flooding is possible must: A. be mounted above flood level. B. utilize NEMA 1 enclosures. C. be mounted under an overhanging eave. D. use water resistant components. - A. be mounted above flood level. The component used to reduce sound transmission and prevent water leaks on a rooftop air conditioner packaged unit installation is the: A. curb gasket. B. silicone caulk. C. roof flashing. D. roofing tar. - A. curb gasket. Return air leakage in a hot attic will: A. Increase capacity B. Decrease capacity C. Increase airflow D. Decrease airflow - B. Decrease capacity An air conditioner refrigerant circuit should be evacuated to a minimum of: A. 0 microns. B. 200 microns. C. 500 microns. D. 1200 microns. - C. 500 microns. Which of the following substances could create an extremely dangerous condition if used to check refrigeration system for leaks? A. R-22 B. Nitrogen C. Oxygen D. Carbon Dioxide - D. Carbon Dioxide The subcooling method for checking charge is generally used on air conditioners with what type of metering? A. Only externally equalized thermostatic expansion valves B. Any thermostatic expansion valve C. Piston type D. Any fixed metering device - B. Any thermostatic expansion valve Supply ducts running through unconditioned space should be insulated and have: A. equal friction. B. excessive air velocity. C. a vapor barrier. D. a transition backing. - C. a vapor barrier. An important consideration when installing a motorized economizer is to check to be certain that: A. the vanes are set for a maximum 10% outdoor air. B. the vanes open on any call for cooling. C. the vanes operate without binding. D. the vanes are permanently set at 50%. - C. the vanes operate without binding. On a 3 ton unit installation, the measure airflow equals 1550 CFM. What does this indicate? A. Proper balancing B. Low Airflow C. Excess airflow D. Improper balancing - C. Excess airflow(400cfm per ton, 3 ton=1200cfm)

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ACADEMICMATERIALS City University New York
View profile
Follow You need to be logged in order to follow users or courses
Sold
569
Member since
2 year
Number of followers
186
Documents
10590
Last sold
14 hours ago

4.1

96 reviews

5
53
4
12
3
21
2
3
1
7

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions