ABRET (3) Questions with verified answers.
What type of montage is shown in this sample? correct answers Referential Montage Which montage would best display the amplitude of a left temporal spike? correct answers Left temporal to the contralateral ear Referential recording is most appropriate for measuring? correct answers Voltage How can a defective electrode be identified? correct answers Placing a bad electrode with high impedance into a pin position with working non reference electrode will result high impedance To confirm the integrity of a poorly recording electrode, the tech should...? correct answers Replace the electrode with a low impedance in the connection of the poorly recording electrode and recheck impedance 14- and -6/sec Hz positive spikes are best demonstrated with a reference to? correct answers Contralateral ear reference When using the average reference, if a spike-and-wave focus appears at C3, the abnormality would be best enhanced by? correct answers Excluding C3 and surrounding electrodes from reference A patient with suspected asymmetrical low-voltage fast activity is observed to have a sweat artifact during the EEG recording. Which of the following EEG settings could be used to reduce the effects of the artifact? correct answers S= 5 microvolts/mm, LFF=5 Hz, HFF = 70 Hz In a referential montage localization is determined by? correct answers Amplitude Switching an effective electrode located in a bad pin position and a good electrode located in working pin position will result in..? correct answers Bad electrode-high impedance in a good pin position; good electrode- high impedance in bad pin position A defective headbox pin can be identified by...? correct answers Placing a non reference electrode with low impedance into a bad pin will result low impedance Increasing the number of seconds displayed on the monitor correct answers Does not change spike amplitude or duration - it shrinks the picture of the displayed waves Which of the following setting is most sensitive correct answers 2 µV/mm A waveform of 0.5 Hz can be best enhanced with a filter of correct answers LFF of 0.3 Hz Which of the following time constants would best display delta activity? correct answers 1.0 second Time constant correct answers Low frequency filter
Written for
- Institution
- ABRET
- Course
- ABRET
Document information
- Uploaded on
- May 21, 2024
- Number of pages
- 4
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
what type of montage is shown in this sample
Document also available in package deal