API 653 SECTION 6 EXAM 100% QUESTIONS WITH CORRECT ANSWERS 2024
API 653 SECTION 6 EXAM 100% QUESTIONS WITH CORRECT ANSWERS 2024 The purpose of in-service inspections of AST's is to assure : - ANSWERS continued tank integrity. What type of inspection may be done by owner/ operator personnel and/or authorized inspectors? - ANSWERS Routine in-service inspection The external condition of storage tanks shall be monitored by close visual inspection from the ground on a routine basis.This inspection can be done by owner/operator personnel,and can be done by the other than Authorized Inspector. The interval of such inspections shall not exceed: - ANSWERS 1 month All tanks shall be given a visual external inspection by an Authorized Inspector, at least every: - ANSWERS 5years or at RCA/4N years,whichever is less External ultrasonic thickness measurements of the shell, when used and when the corrosion rate is not known, are taken at intervals not to exceed: - ANSWERS 5 years Who assures the competency of the personnel performing cathodic protection surveys ? - ANSWERS Owner/ operator A candidate tank is: - ANSWERS A tank for which corrosion rates are not known Two reasons for an internal inspection of an aboveground storage tank are to ensure that the : - ANSWERS bottom is not severely corroded and to gather data on the minimum bottom & shell thickness Who assures the quality and completeness of NDE results obtained during a formal internal inspection? - ANSWERS The API authorized inspector & competent NDE person If an internal inspection is required solely for the purpose of determining the condition and integrity of the tank bottom, the internal inspection: - ANSWERS must be made only after the tank is removed from service and readied for entry The initial inspection interval for an aboveground storage tank shell not exceed _____ years (excluding leak protection, corrosion mitigation or containment safeguards ). - ANSWERS 10 A tank's bottom is inspected. What thickness must the bottom plate be at the next inspection ? The tank bottom/foundation design has no means for detection and containment of a bottom leak. - ANSWERS 0.10 inches What is the maximum subsequent internal inspection interval for an AST where the Corro Procedure is used & there is no release prevention barrier (RPB)? - ANSWERS 20 What is the maximum subsequent inspection interval for an AST using corrosion rate procedure where tank has proper Release Prevention Barrier(RPB)? - ANSWERS 30 years Which of the following is a "likelihood" factor when doing RBI on an AST? - ANSWERS operating temperature Which of the following is a "consequence" factor when doing RBI on an AST? - ANSWERS dike containment capabilities As an alternate to the set maximum intervals of internal inspection given in paragraph 6.4.2 of API 653, an owner- operator may establish the subsequent internal inspection interval using: - ANSWERS risk-based inspection (RBI) procedures Name the three types of records the owner/ operator is required to keep for AST's . - ANSWERS construction records, inspection history,and repair/alteration history Which of the following items would NOT be included in an inspector's report following an external or internal inspection of an Atmospheric Storage Tank ? - ANSWERS Corrosion rate of the tank' s roof. Some repairs to a tank may be made after it has returned to service. Which of the items listed below is considered critical and must be made prior to returning the tank to service ? - ANSWERS Bottom or shell repairs A 30 feet diameter Atmospheric Storage Tank with single lap welded seams has a lower shell course shell plate replaced.What joint factor would you use for the evaluation of the tank shell vertical seams. - ANSWERS 0.35" Personnel performing ______shall meet the qualifications identified in paragraph 12.1.1.2 of API 653 , but need not be certified in accordance with appendix D of API 653 - ANSWERS Nondestructive examinations. The exterior surface of the tank bottom is known as the ________ - ANSWERS Bottom side (3.6) What is a device that protects atmospheric storage tanks by maintaning the pressure difference between the tank vapor space and the outside atmosphere to just a few ounces per in^2? - ANSWERS Pressure-vacuum vent (4.2.2) What is the most common type of atmospheric storage tank? - ANSWERS Fixed cone roof tank (4.2.3) What is the purpose of a geodesic dome on a tank? - ANSWERS Strenght (4.2.3) Why are
Written for
- Institution
- API 653
- Course
- API 653
Document information
- Uploaded on
- May 16, 2024
- Number of pages
- 14
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
api 653 section 6 exam 100 questions with corre
-
api 653 section 6 exam 100 questions with correct
Also available in package deal