CETP PROPANE PRACTICE TESTS with Verified Solutions Latest
CETP PROPANE PRACTICE TESTS with Verified Solutions Latest According to the Two Permanent Openings Method one opening must commence within ____ and one must commence within ___ of the enclosure - Answer -12 inches of the top 12 inches of the bottom Room heaters shall NOT be installed in what occupancies? - Answer -Health care and Residential board and care. Define a type B-W gas vent: - Answer -It shall not have a listed capacity NOT LESS than that of the listed vented wall furnace to which it is connected. Listed vented wall furnaces shall use which type of venting system? - Answer -Type B-W gas vent NO portion of a venting system shall extend or pass through any.... - Answer -Fabricated air duct OR Furnace plenum The exit terminals of mechanical draft systems shall not be LESS than ___________ when located adjacent to public walkways. - Answer -7 ft above finished ground level Forced draft systems and all portions of induced draft systems under positive pressure during operation shall be designed and installed so as to _____________. - Answer -Prevent leakage of flue gases into the building Mechanical draft systems shall be _______ . - Answer -Listed A chimney for residential type or low heat appliances shall extend at least 2 feet higher than any portion of a building within a horizontal distance of _______. - Answer -10 feet Category I Vented appliance - Answer -An appliance that operates with a non-positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent. Type 1 and Type 2 clothes dryers shall be exhausted to the ________. - Answer -Outside Ventilating hoods and exhaust systems shall be ________ installed in commercial applications and to vent industrial equipment. - Answer -Permitted to vent gas appliances What appliances are NOT required to be vented? - Answer -Counter appliances or Direct gas-fired makeup air heaters What is the correct spacing of supports for 3/4" or 1" steel pipe? - Answer -Every 8 feetRegarding indoor combustion air, what method states the minimum volume shall be 50 cube feet per 1000 Btu/hour? - Answer -Standard method All dispensers shall be installed on what type of foundation? - Answer -Concrete The number of containers in a building undergoing minor renovations shall NOT exceed the ________ assigned to using the LP-gas. - Answer -Number of workers and shall not exceed ______ lbs in size Aboveground containers shall be ________. - Answer -Painted All regulators for outdoor installations shall be designed, _______ or protected so that operation will not be affected by
Written for
- Institution
- Cetp
- Course
- Cetp
Document information
- Uploaded on
- April 25, 2024
- Number of pages
- 14
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
cetp propane practice tests 2024
-
cetp propane practice tests 2025
-
according to the two permanent openings method one
Also available in package deal