Hydronic Airstats are found on what type of heating systems? - Correct Answer ✔️✔️-Forced warm air systems Under sized returns on a warm air system can result in what? - Correct Answer ✔️✔️-
Short cycling of the oi l burner Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a steam system? - Correct Answer ✔️✔️-Some radiators not heating quickly enough Low boiler water temperature in a hydronic hot water system may be caused by? - Correct Answer ✔️✔️-Undersized oil burner nozzles Delayed opening oil valves are used to? - Correct Answer ✔️✔️-Allow oil pump to come up to speed If a steam boiler is to be installed with an automatic feeder it must also have: - Correct Answer ✔️✔️-A backflow prevention device How can a damaged heat exchanger be detected on a forced warm air system? - Correct Answer ✔️✔️-With a smoke trace candle If a high limit is installed to prevent high boiler water temperature, what is the function of the low limit? - Correct Answer ✔️✔️-To maintain temperature for domestic hot water On a steam system, a plugged siphon loop can have what affect on the heating system? - Correct Answer ✔️✔️-Insufficient heat in the living space