IF a heat pump works normally in the heating mode but will not provide cooling or a defrost mode, which component is most likely defective? - ANSWER Reversing valve Air-to-air heat pumps produce heat by - ANSWER extracting heat from the outdoor air and transferring it to the indoor air In addition to the reversing valve, the other major difference between a heat pump and a cooling only system is - ANSWER heat pumps require two metering devices In the cooling mode, the reversing valve is normally - ANSWER energized When a heat pump is operating in the heating mode, the refrigerant bypasses the - ANSWER indoor coil metering device In the reverse cycle heating mode, - ANSWER the indoor coil acts as a condenser Refer to figure RQ01. What happens in the cooling mode if the discharge temperature switch fails to close? - ANSWER The outdoor fan does not run Refer to figure RQ02. If the outdoor thermostat is not closed and this system is in the heating mode, a likely symptom would be - ANSWER less supplemental heat available Refer to figure RQ03. Defrost is initiated by - ANSWER defrost control Which of the following conditions is not common and proper during the defrost mode? - ANSWER The compressor shuts off If a heat pump blows cool air into the conditioned space during the colder parts of the heating season, a possible cause is - ANSWER that the supplemental electric heaters are not on during defrosting During dual fuel heat pump operation, the compressor and furnace burner can operate together ___. - ANSWER during periods of defost Refer to figure RQ04. The variable-speed indoor fan motor receives low voltage input signals by the way of ___. - ANSWER a 16-pin connector If a heat pump will not initiate defrost and you suspect the reversing valve, the quickest way to verify your suspicion is to - ANSWER see if the reversing valve switches when the operating mode is changed Low primary voltage at the control circuit transformer may cause - ANSWER relay chatter

Show more Read less
Institution
HVAC II
Course
HVAC II








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
HVAC II
Course
HVAC II

Document information

Uploaded on
April 19, 2024
Number of pages
4
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersmaster01 Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
281
Member since
2 year
Number of followers
106
Documents
14087
Last sold
6 days ago
PAPERSMASTER01

On this page you will find documents , package deals, flashcards offered by seller PAPERSMASTER01.With our documents on your side you"ll be well equipped to tackle you exams and achieve the grades you need.

3.9

71 reviews

5
22
4
33
3
9
2
3
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions