100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Practice Exam SPI All Answers Correct

Beoordeling
-
Verkocht
-
Pagina's
15
Cijfer
A+
Geüpload op
19-04-2024
Geschreven in
2023/2024

Practice Exam SPI All Answers Correct Continous Wave transducer structure and function CW probes usually have no backing material Duty Factor of 100% Console Adjustment that will improve the temporal resolution on the image decreasing depth 7 Best UK Staycations for Your Next Caravan Holiday The rectus abdominis muscles are associated with_____________________, while the diaphragm is associated with__________________ refraction artifact, mirror image artifact You are scanning a Thyroid gland with a 5 cm wide linear array transducer. You are unable to document the upper and lower poles in the same image to obtain a length measurement of the gland. Which of the following techniques should assist in documenting the entire thyroid gland on a single image? panoramic imaging trapezoidal feild of view dual screen function IF a Doppler system is operating at a PRF of 5,000/s what is the maximum Doppler frequency that can be detected? 2.5kHz or 2500Hz because Nyquist Limit=1/2 x PRF If an ultrasound beam passes from soft tissue through a large fatty mass and then back into soft tissue, what will be displayed on the image Echoes from tissues posterior to the mass will be placed deeper on the image soft tissue speed is slower than soft tissue The wider the element diameter, the lower the beam intensity (I=P/A) ____________can be used to reduce image noise and clutter on the 2D image Spatial Compounding SonoCT beam steering, averaging, reduction of speckle, clutter, and imaging artifacts Which of the following will increase the duty factor of the pulsed ultrasound probe? decreasing the image depth increases PRF machine spends more time emitting pulses As beam width increases, how is intensity affected decreases A 5MHz transducer has a PRF of 6kHz and is being used to produce a wace with a 0.6mm wavelength and a 3mm spatial pulse length. What is the axial resolution of this system? 1.5 RESax= SPL/2 If you use a tissue phantom that contains a substance with an average propagation speed of 1600cm/s to calculate a standard ultrasound system, how will this affect the depth calibration testing reflectors will appear more shallow than they actually are located within the phantom tissue-equivalent phantoms=1540 m/s prop speed How can you adjust the elevation focus to a more superficial location in a 1D array transducer use a stand off pad focus 1m closer 1D array transducers set by an acoustic lens The average attenuation of ultrasound in soft tissue is 0.5 db/cm/MHz Which of the following is necessary for a multi hertz transducer broad bandwidth Xdcr can operate at 2 or more different ceneter frequencies Blood is flowing toward a 7MHz transducer; you expect the reflected frequency to be ________7MHz. greater than (positive) Which of the following is a limitation of Analog Doppler unable to detect post stenotic turbulence and spectral broadening underestimates high velocities overestimates low velocities cannot detect flow less than 6 m/s Increasing the angle of electronic steering causes___________production of lobe artifact. increased steering causes diffraction of the beam to occur/lobe artifacts errors in position of returning echo When a patient is supine, what is the hydrostatic pressure at the ankles? 0mmHg at the level of the heart Important to know for ABI According to the attached color map, what color will the blood be demonstrated that is moving away from the probe at 30 cm/s and is highly turbulent Green green and yellow indicate turbulence What happens to the attenuation coefficient as the wave travels through soft tissue remains constant it will remain constant until it travels through a diff medium Which of the following system functions allows the linear transducer to offer a trapezoidal field of view Electronic Steering beam can be steered outward laterally The best angle of insonation to produce the most accurate Doppler shift information is _________degrees. 0 best obtainable angle of insonation is 60 degrees. Which of the following describes an important reason to verify the US examination that is ordered is the exam that should really be performed When the suspected diagnosis is not able to be evaluated by the exam that is ordered Which of the following correctly describes the color displayed on the image? The heel-to-toe method can be used to change the course of the vessel across the image and this will allow the vessel to accurately display a single color The main advantage of a curvilinear transducer over a vector transducer is the wider near field Which of the following fetal structures carries the greatest risk of thermal injury from ultrasoun

Meer zien Lees minder
Instelling
Practice SPI
Vak
Practice SPI









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Practice SPI
Vak
Practice SPI

Documentinformatie

Geüpload op
19 april 2024
Aantal pagina's
15
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
CertifiedGrades Chamberlain College Of Nursing
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
144
Lid sinds
3 jaar
Aantal volgers
61
Documenten
8740
Laatst verkocht
2 weken geleden
High Scores

Hi there! Welcome to my online tutoring store, your ultimate destination for A+ rated educational resources! My meticulously curated collection of documents is designed to support your learning journey. Each resource has been carefully revised and verified to ensure top-notch quality, empowering you to excel academically. Feel free to reach out to consult with me on any subject matter—I'm here to help you thrive!

3.9

38 beoordelingen

5
21
4
6
3
2
2
3
1
6

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen