3rd Class Stationary Steam Engineer License Prep Exam 2024 Questions and Answers.
3rd Class Stationary Steam Engineer License Prep Exam 2024 Questions and Answers. are necessary for complete combustion - Answer<>time, temperature, mixture, and atomization if the steam pressure gauge indicates 200 PSIG, the absolute pressure is______ - Answer<>214.7 a boiler is operating at 400 PSI, and the safety valve opens at 410 PSI and closes at 398 PSI. The blowdown is______psi - Answer<>12 an oil cooler is commonly used with a(n) ________ when operating in conjunction with a turbo-generator - Answer<>steam turbine a boiler is producing 40,000lb of steam/hr at a pressure of 100 PSI and a steam temperature of 500 degrees Fahrenheit. The steam produced is _______ steam - Answer<>superheated the economizer on a boiler is used to _______ - Answer<>add heat to the feed water blowers are normally used with________ boilers - Answer<>water tube overheating of tubes on a boiler can be caused by________ - Answer<>scale on tubes carbon dioxide in a condensate return system causes_________ - Answer<>channeling a ________ pump is a positive displacement pump - Answer<>reciprocating a boiler generating 6000 lb of steam/hr produces _______btu/hr - Answer<>6,000,000 a bottom blowdown is performed on a boiler to _____ - Answer<>discharge sludge and sediment water columns are connected to the boiler with a minimum of _______" pipe - Answer<>1 the minimum size of a water column blowdown valve is_______". - Answer<>3/4 the maximum size bottom blowdown valve on a boiler is_________". - Answer<>2 1/2 a ________ allows condensate to pass through, but stops Steam. - Answer<>a steam trap when taking over a shift, the first thing to do is check the________ - Answer<>water level in each boiler according to the asme code, a high-pressure boiler having more than 500 square feet of heating surface shall have________ - Answer<>two or more safety valves the probable cause of an increase in temperature of gases of combustion at the boiler Outlet is____ - Answer<>dirty heating services boilers in battery equipped with________ must have two main steam stop valves and a free-flowing drain between them - Answer<>manhole openings in order to be sure the gauge glass is indicating an accurate water level reading, the stationary engineer should______ - Answer<>blowdown the gauge glass a continuous blowdown line is located___ - Answer<>in the Steam and water drum well below the nowl a temperature reading of 80 degrees Celsius is equal to_________°f - Answer<>176 a chimney temperature of 250 degrees Fahrenheit above steam temperature indicates_______ - Answer<>poor efficiency a manometer is red in________ - Answer<>inches of water the boiling point of water will____ with an increase in pressure - Answer<>be raised if a lather is not obtained when performing a soap hardness test, the water sample is_______ - Answer<>hard combustion efficiency can be increased when air is________ - Answer<>preheated ______ draft is produced by a fan located between the boiler and the chimney - Answer<>induced the overspeed trip on a steam turbine should be tested ______ - Answer<>before putting the steam turbine on-line a high CO2 reading in the gases of combustion is a sign of____ - Answer<>High combustion efficiency the purpose of chemically treating feedwater is to________ - Answer<>turn scaleforming salts to a non adhering sludge water in a d rating feed water heater is prevented from entering the steam line by a(n) _______. - Answer<>Loop seal or internal overflow a steam turbine operating at 3600 RPM will trip at_________ rpm - Answer<>3960 .
Geschreven voor
- Instelling
- Stationary Steam Engineer License
- Vak
- Stationary Steam Engineer License
Documentinformatie
- Geüpload op
- 15 april 2024
- Aantal pagina's
- 15
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
- stationary steam
-
3rd class stationary steam engineer license
-
stationary steam engineer license prep exam 2024
-
stationary steam engineer license exam 2024
-
stationary steam engineer license exam latest