100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

TFM 12 Fire Alarm Technical Exam Containing 91 Questions with Certified Solutions Updated .

Rating
5.0
(1)
Sold
1
Pages
16
Grade
A+
Uploaded on
27-03-2024
Written in
2023/2024

TFM 12 Fire Alarm Technical Exam Containing 91 Questions with Certified Solutions Updated . Terms like: Does a fire hood system and a kitchen need to be monitored by the fire alarm system? - Answer: Yes

Institution
TFM 12 Fire Alarm Technical Exm Containing 91 Que
Course
TFM 12 Fire Alarm Technical Exm Containing 91 Que










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
TFM 12 Fire Alarm Technical Exm Containing 91 Que
Course
TFM 12 Fire Alarm Technical Exm Containing 91 Que

Document information

Uploaded on
March 27, 2024
Number of pages
16
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

TFM 12 Fire Alarm Technical




TFM 12 Fire Alarm Technical Exam
Containing 91 Questions with Certified
Solutions Updated 2024-2025.
Does a fire hood system and a kitchen need to be monitored by the fire alarm
system? - Answer: Yes


What does P.L.F.A stand for? - Answer: Power Limited Fire Alarm

, TFM 12 Fire Alarm Technical


What does N.P.L.F.A stand for? - Answer: Non-Power Limited Fire Alarm


What is the difference between P.F.L.A and N.P.F.L.A? - Answer: an N.P.L.F.A can
operate at up to 600v, and the power output isn't limited


a P.L.F.A has the voltage and power limited by a listed power source.


What material must N.P.F.L.A circuit conductors be made from? - Answer: ONLY
solid stranded copper is permitted.


What does A.W.G stand for? - Answer: American Wire Gauge


What size conductors are permitted? - Answer: Size 18 A.W.G and 16 A.W.G are
permitted, provided they do not exceed certain capacities.


What is used to protect transformers or other devices supplied from power-supply
conductors? - Answer: An over-current device not rated over 20 amperes.


When located within 7 feet of the floor, how shall cables be fastened? - Answer:
Cables shall be fastened in an approved manner at intervals of not more than 18
inches.


Single conductors shall not be smaller than ___ A.W.G? - Answer: 18

, TFM 12 Fire Alarm Technical


Conductors of 28 A.W.G shall only be permitted in which circumstance? - Answer:
Spliced with a connector listed as suitable for 26 to 24 A.W.G


How shall P.F.L.A conductors NOT be installed? - Answer: P.F.L.A conductors shall
not be strapped, taped, or attached to the exterior of any conduit or raceway.


What is Plenum cable? - Answer: Cable that can be installed in ducts, plenums, or
other spaces used for environmental air.


What is a Riser cable? - Answer: Cable to be used in vertical wire runs in shafts
between floors. Not to be used where Plenum cable is required.


It is capable of preventing fire from rising from floor to floor.


What is general purpose cable? - Answer: Cable for general purpose fire alarm
use. Not to be used where plenum cable or riser cable is required.


It is resistant to the spread of fire.


Why 'type' shall plenum cable be? What substitutions are allowed? - Answer:
Power Limited Fire Alarm Plenum (F.P.L.P) C.M.P can be substituted.


Why 'type' shall riser cable be? What substitutions are allowed? - Answer: Power
Limited Fire Alarm Riser (F.P.L.R) C.M.P, F.P.L.P.

Reviews from verified buyers

Showing all reviews
4 months ago

5.0

1 reviews

5
1
4
0
3
0
2
0
1
0
Trustworthy reviews on Stuvia

All reviews are made by real Stuvia users after verified purchases.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Studyresource1 Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
7242
Member since
1 year
Number of followers
24
Documents
1361
Last sold
9 hours ago
EXCELLENT TUTOR.

Veteran teacher / Tutor with years of experience planning and implementing study documents, case studies, test banks and all kinds of exams questions with well articulated answers for students. Passionate and highly effective with success in study guide strategies to develop students\' academic skills and raise test scores.

4.6

708 reviews

5
490
4
148
3
58
2
10
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions