100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

API 653 Data Sheets Questions and Answers 100% Correct

Beoordeling
-
Verkocht
-
Pagina's
13
Cijfer
A+
Geüpload op
23-03-2024
Geschreven in
2023/2024

API 653 Data Sheets Questions and Answers 100% Correct Fitness For Service - Answer- API 579 Low Pressure Storage Tanks - Answer- API 620 Risked Based Inspection - Answer- API 580 Cathodic Protection - Answer- API 651 Tank Bottom Linings - Answer- API 652 Welding on in service equipment containing flammables - Answer- API 2201 NDE Procedure Guidlines - Answer- ASME Section V Acceptance Standards for RT of welds - Answer- ASME Section 8, Div. 1 Alternative evaluation for pits and LTA's - Answer- ASME Section 8, Div. 2 Welder Qualification - Answer- ASME Section IX Weld Procedure Qualification - Answer- ASME Section IX Impact testing method and equipment requirements - Answer- ASTM A370 Requirement for new welding electrodes - Answer- AWS NDE personnel qualification (RT and UT flaw detection) - Answer- ASNT SNT-TC-1A API 650 Appendix for frangible roofs - Answer- Appendix F API 650 Appendix for hot tanks - Answer- Appendix M Maximum allowed vertical length of pits on a tank shell - Answer- 2" in 8" Line Max allowed length of pits in the critical zone that can be repaired by weld build up - Answer- 2" in 8" arc Radial length of critical zone measured from shell - Answer- 3" Bottoms- suggested pad thickness - Answer- 3-4" Minimum distance between clusters of surface porosity - Answer- 4" Minimum dimension of shell lap-patch - Answer- 4" Minimum radius of shell flush-patch - Answer- 6" When calculating tmin for shell LTA, minimum distance away from a rivet where "E" is always 1.0 - Answer- 6" Minimum size of a bottom lap-patch that does NOT cross a bottom seam - Answer- 6" Minimum distance between a bottom lap patch and the shell for patches that do NOT extend to the shell - Answer- 6" If reusing shell plates, minimum distance to cut from existing shell welds (if plates are not deseamed) - Answer- 6" Minimum diagnostic length of RT for vertical or horizontal welds - Answer- 6" Minimum length of RT when qualifying a welder with RT using a coupon or 1st production weld - Answer- 6" Minimum length of RT when qualifying a weld operator with a test coupon - Answer- 6" Minimum distance to overlap a shell weld when using a lap patch - Answer- 6" Area to dig when checking for soil-to-air corrosion - Answer- 6-12" Typical size of a vacuum box - Answer- 6"X30" Minimum dimension of a shell flush patch - Answer- 12" or 12 times thickness of replacement plate, whichever is greater Bottoms-minimum distance a 3 lap joint can be from: other 3 lap joints, the shell or annular plate joints - Answer- 12" Minimum dimension of bottom lap patch that crosses a bottom seam - Answer- 12" Foundations- suggested height above grade for new tank bottoms - Answer- 12" When adding a shell flush patch that extends to a horizontal shell weld, minimum distance to cut the horizontal weld past the new vertical welds - Answer- 12" Length of shell to bottom weld that if repaired is considered either a major repair or alteration - Answer- >0" Typical anchor profile of steel surface required for installation of a tank bottom lining - Answer- 1.5-4.0 mils Maximum undercut of a vertical weld and nozzle weld - Answer- 1/64" Maximum undercut of a horizontal weld - Answer- 1/32" Maximum diameter of surface porosity cluster - Answer- 3/32" Maximum allowed discontinuity in a bend test - Answer- 1/8

Meer zien Lees minder
Instelling
API 653
Vak
API 653









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
API 653
Vak
API 653

Documentinformatie

Geüpload op
23 maart 2024
Aantal pagina's
13
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
EmilyCharlene Teachme2-tutor
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
444
Lid sinds
2 jaar
Aantal volgers
138
Documenten
21009
Laatst verkocht
22 uur geleden
Charlene\'s Scholastic Emporium.

Your Actual and Virtual Exam Tests Excellent Tutor.

3.6

97 beoordelingen

5
45
4
13
3
15
2
7
1
17

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen